Configure the settings relating to Panasonic alarm protocol [Panasonic alarm protocol setup]
Click the [Notification] tab on the "Alarm setup" page. (☞ page 28)
The settings relating to Panasonic alarm protocol can be configured on this page.
[Panasonic alarm protocol]
Select "ON" or "OFF" to determine whether or not to notify of an alarm occurrence by Panasonic alarm proto- col when an alarm is detected.
Default: OFF
[Destination port]
Select a destination port of the Panasonic alarm proto- col from the following.
Available port number: 1 - 65535
Default: 1818
[Retry times]
Select a retry time of Panasonic alarm protocol.
Available retry times: 1 - 30
Default: 2
[IP address]
Enter the destination IP address of the Panasonic alarm protocol from the following. Up to 8 destination address- es can be registered.
To notify by Panasonic alarm protocol, check the "Notification setup" checkbox respective to the desired IP address. To delete the registered IP address, click the [DEL] button respective to the desired IP address.
34