Avery ALS 230 manual Product menu

Page 43

Operators Manual

ALS 230

5.3 Product menu

If parameters have to be changed because of different products and labels, the product menu can be used. The machine offers a data bank in which 14 sets of data can be stored.

If you want to switch to a particular product, select one of the product numbers by pressing NEXT or PRIOR and confirm with ENTER .The new parameters are valid now.

After switching to a new product bank the machine assumes the label roll has been changed or that a parameter such as STOD is different and so requires an initialisation of the label position at the dispensing edge. This is done by pressing the FEED key after loading a new product bank at which time the machine will move the first detected label edge to the dispense position.

Note: If the FEED key is not pressed after loading a new product bank the first detected label edge will be moved to the dispense position at the first signal from the product sensor!

Note: The function FACT available in the configuration menu clears all the product banks.

Release 11/05

Page 41

Menu structure

Image 43
Contents Page Page ALS Menu structure Errors and warnings Copyright Important NotesOverview ManufacturerGeneral Safety Notes SafetyOperator’s duty of care Concrete security regulations and symbols used Security measures during normal operation Security measures during maintenance and repairsWork on pneumatic equipment Work on the electrical equipmentObserve environmental regulations Page Mechanics DescriptionDispensing mechanics Operator panel Operator panelALS Electronic Plug boardALS Unpacking of the unit InstallationGeneral setting Preparing the machineInsert material Prepare dispensingDefine label data Manual adjustment of the Cont parameter Setting Lpit manuallyCapacitive label sensor Capacitive sensor Label guideStop position Adjust dispense functionFixed dispensing speed Label position on the product Automatic dispensing speed ApsfProduct data bank Operation Safety recommendationLeft hand version Inserting label material3Initialise new label material Missing label function and web breaks Function Display message Mains switch4Control of dispense unit Dispenser Menu selectionLabel positionPOS Dispenser active onDispenser stopped OFF Material initialisation InitLabel position Stop position StodProduct menu PD0n Start delaySTADDispense speed Velo Blow on time BlowMaintenance Extended standard menu Configuration menuMenu structure Standard menuExtended menu ConfigurationStandard menu  Direct ApplicatorInitialisation Init Standard menuDisplay Function Values Dispensing speed Velo Start delay StadLabel position POS Labelling time BlowDisplay Function Data value Extended standard menuLabel contrast Label pitch LpitSensor status Sens Product length Prdl Dwell time APT1 Electronic gear ratio adjustment EgraEgra value check Stst Slew speed SlewBlow on time APT2 Restart delay APT3Time constant compensation APT4 Load data bank Load End of air stream signal AstpPrinter dwell time PDT Save parameter in data bank SaveProduct menu Release 11/05 Menu structure Possible tests ConfigurationPossible adjustments Calling the configuration menuDisplay Function of the parameter Possible data entry Handling the menuMenu functions Type of applicator Appl Automatic product speed followerAPSFOutput check OCH Input and sensor check ICHAdditional functions in the standard menu Number of stop bits Sbit Adjustment resettingFACTInterface baud rate Baud Parity bit PariLabel counter Labc Number of data bits DbitRecycle simulates max labels/min Recy Distance sensor to dispensing edge DistRelease 11/05 Configuration Data of the serial interface Serial interfaceCommand Description Range Interface commandsExample Ledg Message in display Bit definition in error flagError number Error message in display Error description Bit definition in warning flagOutput signals Connections and signalsApplicator modes Signals for direct dispenseTiming ASA applicator Control signals for the ASA applicatorAPT2 Signals for the EP applicatorApplicator connector Applicator connectorConnecting NPN left or PNP right inputs Input signalsProduct sensor Example for connecting an NPN sensor DatalogicNPN connection of optional ODC sensor OD Control sensorConnection of a NPN type Apsf sensor Apsf sensorOptional connector for process contro Control signalsInternal I/O connector Rule EMIWiring diagram Electronic diagramsLayout dispenser electronic board Jumper position has to be 800 steps Page Message Meaning How to solve Errors and warningsDispenser error messages STO! Power-fail messageInto Eeprom Dispenser warningsALS Technical Information Technical SpecificationDescription Details APSF- Sensor Specification Optional function Application specificationLabels per minute in relation to different label pitches Performance375 125 875 625 ALS Page Function Factory Application AdjustmentFunction PD05 PD06 PD07 PD08 PD09 Function Factory PD01 PD02 PD03 PD04Siehe Machine type Index