Operators Manual
ALS 230
8.3.2OD Control sensor
Optional an OD control could be mounted to control the label roll. If the label material is nearly empty the sensor gives an signal. A warning message and an output signal inform the personal that in the next time the material has to be changed.
NPN sensor
Supply
Signal+
Signal-
GND
| 5 | 5 | white |
brown | 9 | 9 | red |
| 4 | 4 |
|
| 8 | 8 |
|
| 3 | 3 |
|
white | 7 | 7 | green |
| 2 | 2 |
|
| 6 | 6 |
|
grey | 1 | 1 | black |
blue
+24V
11
27
25
14
GND
Figure 17 NPN connection of optional ODC sensor
CN33
+24V
PNP sensor
Supply
Signal+
Signal-
GND
brown | 5 | 5 | white |
| |||
white | 9 | 9 | red |
| 4 | 4 |
|
| 8 | 8 |
|
grey | 3 | 3 |
|
| 7 | 7 | green |
| 2 | 2 |
|
| 6 | 6 |
|
blue | 1 | 1 | black |
11
27
25
14
GND
Figure 18 PNP connection of optional ODC sensor
CN33
Release 11/05 | Page 62 | Connections and signals |