Operators Manual
ALS 230
9. Errors and warnings
The software checks during the labelling permanently, if the machine runs under normal operation. If labelling is not possible, the display shows a message e.g. E__0.
If the labelling can be continued, but a problem has occurred or may occur, the display shows a warning e.g. W__1.
By pressing the key ENTER the message will be erased.
In case of an error or warning message, the relevant output is switched. The signal can be used for interconnection with an external machine control.
Via the serial interface, the errors and warnings number can be called. If an error cannot be erased, please call your local service technician.
9.1 Dispenser error messages
In case of an error message the relevant output is switched. The signal can be used for interconnection with an external machine control.
STO! Power-fail message
The message STO! appears in the display as the machine is switched off or if the mains supply voltage has fallen below specification.
The message STO! (store) indicates that the machine has stored some parameters internally as a power fail condition was detected. The error output is switched active and the ready output inactive simultaneously with STO! appearing in the display.
If the mains supply voltage only experiences a drop in level and then returns to a correct level then the ready output is restored to its previous condition but the message STO! will remain in the display to indicate that there has been a problem with the mains supply.
Message | Meaning | How to solve |
E__0 | Pressure roller is open | Close the pressure roll and make a new |
|
| initialisation if necessary |
E__1 | During material transport no label | Insert new material and check the label |
| is recognised over a length of 4 | sensor |
| labels |
|
E__2 | EP applicator not in HOME | Check air supply. |
| position | Applicator not connected. |
|
| HOME switch not adjusted |
E__3 | Check sum of the configuration | Call the configuration menu and adjust |
| data is wrong. All Parameters are | all parameters again. |
| set |
|
Release 11/05 | Page 71 | Errors and warnings |