Avery ALS 230 manual Interface commands, Example, Command Description Range

Page 54

Operators Manual

ALS 230

7.2 Interface commands

The below described commands will change one of the labelling parameter. The values are not stored and will be lost when turning off power.

If the sequence nnnn is replaced by the character "?" then the current value of that parameter will be returned by the labelling machine as a 4 character string confirming the name of the parameter requested followed by 4 numbers representing the current value of that parameter. The character 04H terminates all return messages.

Example

 

 

 

 

PC send the message:

#!VELO?

 

 

Machine returns:

 

VELO0300<04H>

 

 

 

 

 

Command

Description

Range

#!APOSnnnn

Value APOS

-0050 – 0100 mm

 

 

 

#!APPLnnnn

Applicator type

0000 direct dispense

 

 

 

0001 ASA

 

 

 

0002 EP

 

 

 

0003 EP_U

 

 

 

0004 PLUA

 

 

 

0005 INDX

 

 

 

#!APSFnnnn

APSF function

0000 off

 

 

 

0001 on

 

 

 

 

#!APT1nnnn

Applicator time

0001

– 7500 ms

 

 

 

 

#!APT2nnnn

Applicator time

0001

– 7500 ms

 

 

 

 

#!APT3nnnn

Applicator time

0000

– 5000 ms

 

 

 

#!ASTPnnnn

Value ASTP

-0020 – 0050 mm

 

 

 

 

#!BANKnnnn

Change product bank

0000

- 0009

 

 

 

 

#!BLOWnnnn

Blow on time = APT 2

0001

- 7500 ms

 

 

 

 

#!COMPnnnn

Automatic label compensation

0000

= Off

 

 

 

0001

= On

 

 

 

 

#!CONTnnnn

Material contrast

0001

– 0200

 

 

 

0000 automatically

 

 

 

 

#!DISTnnnn

Distance label sensor – dispensing

0080

– 9999 * 0.1 mm

 

edge

 

 

 

#!EGRAnnn

Gear ratio

0300

– 1000

 

 

 

 

#!LPITnnnn

Label length

0005

– 0999 mm

 

 

 

0000 automatically

 

 

 

#!MACHnnnn

Machine type

0000 ALS230

 

 

 

0001 ALX720

 

 

 

0002 ALS330

 

 

 

0003 ALS430

 

 

 

 

 

Release 11/05

 

Page 52

 

Serial interface

Image 54
Contents Page Page ALS Menu structure Errors and warnings Manufacturer Important NotesOverview CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationWork on the electrical equipment Work on pneumatic equipmentObserve environmental regulations Page Description MechanicsDispensing mechanics Operator panel Operator panelALS Plug board ElectronicALS Preparing the machine InstallationGeneral setting Unpacking of the unitPrepare dispensing Insert materialDefine label data Setting Lpit manually Manual adjustment of the Cont parameterCapacitive label sensor Label guide Capacitive sensorAdjust dispense function Stop positionFixed dispensing speed Automatic dispensing speed Apsf Label position on the productProduct data bank Safety recommendation OperationInserting label material Left hand version3Initialise new label material Dispenser Menu selection Function Display message Mains switch4Control of dispense unit Missing label function and web breaksMaterial initialisation Init Dispenser active onDispenser stopped OFF Label positionPOSStop position Stod Label positionBlow on time Blow Start delaySTADDispense speed Velo Product menu PD0nMaintenance Standard menu Configuration menuMenu structure Extended standard menuApplicator ConfigurationStandard menu  Direct Extended menuStandard menu Initialisation InitDisplay Function Values Labelling time Blow Start delay StadLabel position POS Dispensing speed VeloExtended standard menu Display Function Data valueLabel pitch Lpit Label contrastSensor status Sens Product length Prdl Slew speed Slew Electronic gear ratio adjustment EgraEgra value check Stst Dwell time APT1Restart delay APT3 Blow on time APT2Time constant compensation APT4 Save parameter in data bank Save End of air stream signal AstpPrinter dwell time PDT Load data bank LoadProduct menu Release 11/05 Menu structure Calling the configuration menu ConfigurationPossible adjustments Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplInput and sensor check ICH Output check OCHAdditional functions in the standard menu Parity bit Pari Adjustment resettingFACTInterface baud rate Baud Number of stop bits SbitDistance sensor to dispensing edge Dist Number of data bits DbitRecycle simulates max labels/min Recy Label counter LabcRelease 11/05 Configuration Serial interface Data of the serial interfaceInterface commands Command Description RangeExample Ledg Bit definition in warning flag Bit definition in error flagError number Error message in display Error description Message in displayConnections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagramLayout dispenser electronic board Jumper position has to be 800 steps Page STO! Power-fail message Errors and warningsDispenser error messages Message Meaning How to solveInto Dispenser warnings EepromALS Technical Specification Technical InformationDescription Details Application specification APSF- Sensor Specification Optional functionPerformance Labels per minute in relation to different label pitches375 125 875 625 ALS Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index Siehe Machine type