Operators Manual
ALS 230
#!SR__ | The machine is set to on. The product sensor is enabled and labelling can |
| restart. |
For a full automatic operation, the following procedure in case of an error is required:
• | #!ERRF | Request error |
• | #!CLRE | Clear error message after fixing the error. The labeller shows „INIT“ |
• | #!SR__ | Clear INIT message |
Bit definition in error flag
Error number | Error message in display | Error description |
0 | E__0 | Pressure roller open |
1 | E__1 | End of material (4 missing labels) |
2 | E__2 | |
3 | E__3 | checksum error configuration data |
4 | E__4 | checksum error parameter bank |
5 | E__5 | Error 10V low |
6 | E__6 | Error 24V low |
7 | E__7 | missing label on product |
8 | E__8 | Error motor driver |
Bit definition in warning flag
Warning | Message in display | Warning description |
0 | W__0 | Next product start before finished |
1 | W__1 | Product start but no material not initialised |
2 | W__2 | EEPROM error during write |
3 | W__3 | Interface warning |
4 | W__4 | APSF speed too fast |
5 | W__5 | End of material |
6 | W__6 | too many products |
7 | W__7 | Loop not ready (720) |
Release 11/05 | Page 54 | Serial interface |