Avery ALS 230 manual Into

Page 74

Operators Manual

ALS 230

Message

Meaning

How to solve

 

to the factory adjustment.

 

E__4

Check sum of the labelling data is

All labelling parameter have to be

 

wrong. Labelling Parameters are

adjusted again

 

set to the factory adjustment.

 

E__5

10V supply voltage for label

Short circuit in label sensor or cable.

 

sensor low.

Voltage regulator U14 is damaged.

E__6

24V Voltage low

Short circuit on an output. Total load too

 

 

high i.e. max is 3A for all outputs.

 

 

Voltage regulator U1 is damaged.

 

 

Change main board.

E__7

Material initialization failed

Check if the label web is threaded

 

 

through the label sensor

E__8

Error stepper motor driver

The stepper motor control has detected

 

 

an error. The fault is indicated by the

 

 

LED’s on the driver.

E__9

10V supply for label sensor too

Voltage regulator U14 damaged

 

high

 

E__10

Missing label on product

One or several product could not be

 

 

labelled. Distance between products too

 

 

close. Increase speed of printer.

___0

Process error (Divide overflow)

Hardware failure external noise. EPROM

 

 

damaged. Turn off power and on again.

 

 

Change EPROM or main board

___1

Illegal interrupt (processing error)

Hardware failure external noise. EPROM

 

 

damaged. Turn off power and on again.

 

 

Change EPROM or main board

___2

Illegal bank interrupt (processing

Hardware failure external noise. EPROM

 

error)

damaged. Turn off power and on again.

 

 

Change EPROM or main board

INTO

Illegal interrupt INTP0 (processing

Hardware failure external noise. EPROM

 

error)

damaged. Turn off power and on again.

 

 

Change EPROM or main board.

Release 11/05

Page 72

Errors and warnings

Image 74
Contents Page Page ALS Menu structure Errors and warnings Manufacturer Important NotesOverview CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationObserve environmental regulations Work on the electrical equipmentWork on pneumatic equipment Page Description MechanicsDispensing mechanics Operator panel Operator panelALS Plug board ElectronicALS Preparing the machine InstallationGeneral setting Unpacking of the unitDefine label data Prepare dispensingInsert material Capacitive label sensor Setting Lpit manuallyManual adjustment of the Cont parameter Label guide Capacitive sensorFixed dispensing speed Adjust dispense functionStop position Product data bank Automatic dispensing speed ApsfLabel position on the product Safety recommendation OperationInserting label material Left hand version3Initialise new label material Dispenser Menu selection Function Display message Mains switch4Control of dispense unit Missing label function and web breaksMaterial initialisation Init Dispenser active onDispenser stopped OFF Label positionPOSStop position Stod Label positionBlow on time Blow Start delaySTADDispense speed Velo Product menu PD0nMaintenance Standard menu Configuration menuMenu structure Extended standard menuApplicator ConfigurationStandard menu  Direct Extended menuDisplay Function Values Standard menuInitialisation Init Labelling time Blow Start delay StadLabel position POS Dispensing speed VeloExtended standard menu Display Function Data valueSensor status Sens Label pitch LpitLabel contrast Product length Prdl Slew speed Slew Electronic gear ratio adjustment EgraEgra value check Stst Dwell time APT1Time constant compensation APT4 Restart delay APT3Blow on time APT2 Save parameter in data bank Save End of air stream signal AstpPrinter dwell time PDT Load data bank LoadProduct menu Release 11/05 Menu structure Calling the configuration menu ConfigurationPossible adjustments Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplAdditional functions in the standard menu Input and sensor check ICHOutput check OCH Parity bit Pari Adjustment resettingFACTInterface baud rate Baud Number of stop bits SbitDistance sensor to dispensing edge Dist Number of data bits DbitRecycle simulates max labels/min Recy Label counter LabcRelease 11/05 Configuration Serial interface Data of the serial interfaceExample Interface commandsCommand Description Range Ledg Bit definition in warning flag Bit definition in error flagError number Error message in display Error description Message in displayConnections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagramLayout dispenser electronic board Jumper position has to be 800 steps Page STO! Power-fail message Errors and warningsDispenser error messages Message Meaning How to solveInto Dispenser warnings EepromALS Description Details Technical SpecificationTechnical Information Application specification APSF- Sensor Specification Optional functionPerformance Labels per minute in relation to different label pitches375 125 875 625 ALS Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index Siehe Machine type