Avery ALS 230 manual Ledg

Page 55

Operators Manual

ALS 230

Command

Description

Range

#!MDIRnnnn

Motor direction

0000

Right --- >

 

 

0001

Left < ---

 

 

 

 

#!MLABnnnn

Missing label error

0000

NONE

 

 

0001

Warning

 

 

0002

Error 1

 

 

0003

Error 2

 

 

 

 

#!PDT nnnn

Print dwell time

0001

– 1000 ms

 

 

0000 printer off

 

 

 

 

#!PHT nnnn

Printer hold time

0001

– 7500 ms

 

 

 

 

#!POS_nnn

Labelling position

0001

– 9999 * 0.1 mm

 

 

 

 

#!PRDLnnnn

Product length

0005

– 4000 mm

 

 

 

 

#!P_S_nnnn

Polarity product sensor

0000

LEDG

 

 

0001 TEDG

 

 

 

#!RAMPnnnn

Acceleration Ramp

0000 NORM

 

 

0001 FAST

 

 

 

 

#!SLEWnnnn

Slew speed

0000

= FAST

 

 

0001

= SLOW

 

 

 

 

#!STADnnnn

Start delay

0001

- 9999 ms

 

 

 

 

#!STODnnnn

Stop position

0080

- 9999 * 0.1 mm

 

 

 

 

#!VELOnnnn

Speed

0020

- 0300 * 0.1m/min

 

 

 

 

#!SAVEnnnn

Store in data bank

0001

- 0009

 

 

 

 

#!LOADnnnn

Load data bank

0001

- 0009

 

 

 

 

The following described commands do not have parameter values. With these commands the host can monitor and control the machine.

#!CLRC

Set label counter to 0

 

#!CLRE

Clear error message

 

#!CLRW

Clear warning

 

#!ERRF

The machine sends an error status to the monitoring computer. The message

 

ERR8___4__1_<04H> means, error 8, 4 and 1 have occurred.

 

#!WARF

The machine sends a warning status to the monitoring computer. The message

 

WARF7______0 means: The warnings 7 and 0 have occurred.

 

#!LABC

The machine sends the number of dispensed labels e.g. LABC0000008359 back

#!SP__

The machine is set to off. The product sensor is disabled and labelling will

 

therefore be stopped.

 

Release 11/05

Page 53

Serial interface

Image 55
Contents Page Page ALS Menu structure Errors and warnings Copyright Important NotesOverview ManufacturerGeneral Safety Notes SafetyOperator’s duty of care Concrete security regulations and symbols used Security measures during normal operation Security measures during maintenance and repairsWork on pneumatic equipment Work on the electrical equipmentObserve environmental regulations Page Mechanics DescriptionDispensing mechanics Operator panel Operator panelALS Electronic Plug boardALS Unpacking of the unit InstallationGeneral setting Preparing the machineInsert material Prepare dispensingDefine label data Manual adjustment of the Cont parameter Setting Lpit manuallyCapacitive label sensor Capacitive sensor Label guideStop position Adjust dispense functionFixed dispensing speed Label position on the product Automatic dispensing speed ApsfProduct data bank Operation Safety recommendationLeft hand version Inserting label material3Initialise new label material Missing label function and web breaks Function Display message Mains switch4Control of dispense unit Dispenser Menu selectionLabel positionPOS Dispenser active onDispenser stopped OFF Material initialisation InitLabel position Stop position StodProduct menu PD0n Start delaySTADDispense speed Velo Blow on time BlowMaintenance Extended standard menu Configuration menuMenu structure Standard menuExtended menu ConfigurationStandard menu  Direct ApplicatorInitialisation Init Standard menuDisplay Function Values Dispensing speed Velo Start delay StadLabel position POS Labelling time BlowDisplay Function Data value Extended standard menuLabel contrast Label pitch LpitSensor status Sens Product length Prdl Dwell time APT1 Electronic gear ratio adjustment EgraEgra value check Stst Slew speed SlewBlow on time APT2 Restart delay APT3Time constant compensation APT4 Load data bank Load End of air stream signal AstpPrinter dwell time PDT Save parameter in data bank SaveProduct menu Release 11/05 Menu structure Possible tests ConfigurationPossible adjustments Calling the configuration menuDisplay Function of the parameter Possible data entry Handling the menuMenu functions Type of applicator Appl Automatic product speed followerAPSFOutput check OCH Input and sensor check ICHAdditional functions in the standard menu Number of stop bits Sbit Adjustment resettingFACTInterface baud rate Baud Parity bit PariLabel counter Labc Number of data bits DbitRecycle simulates max labels/min Recy Distance sensor to dispensing edge DistRelease 11/05 Configuration Data of the serial interface Serial interfaceCommand Description Range Interface commandsExample Ledg Message in display Bit definition in error flagError number Error message in display Error description Bit definition in warning flagOutput signals Connections and signalsApplicator modes Signals for direct dispenseTiming ASA applicator Control signals for the ASA applicatorAPT2 Signals for the EP applicatorApplicator connector Applicator connectorConnecting NPN left or PNP right inputs Input signalsProduct sensor Example for connecting an NPN sensor DatalogicNPN connection of optional ODC sensor OD Control sensorConnection of a NPN type Apsf sensor Apsf sensorOptional connector for process contro Control signalsInternal I/O connector Rule EMIWiring diagram Electronic diagramsLayout dispenser electronic board Jumper position has to be 800 steps Page Message Meaning How to solve Errors and warningsDispenser error messages STO! Power-fail messageInto Eeprom Dispenser warningsALS Technical Information Technical SpecificationDescription Details APSF- Sensor Specification Optional function Application specificationLabels per minute in relation to different label pitches Performance375 125 875 625 ALS Page Function Factory Application AdjustmentFunction PD05 PD06 PD07 PD08 PD09 Function Factory PD01 PD02 PD03 PD04Siehe Machine type Index