ALS 230

3. Preparing the machine

In this chapter you will learn how to install and adjust the labeller. After this step has been completed you will be ready to learn how the labeller's parameters can be adjusted to suit your particular production requirements.

1.1 Installation

1.1.1 Unpacking of the unit

For removing the unit off the box, don’t hold the machine on the dispensing edge to prevent disadjustment off the machine.

For mounting the machine, a complete system of holding tools is available. Ask your representative.

Take care that the machine is safe and stable mounted.

There are rotating parts on the machine. Do the necessary actions to prevent that anybody can be caught from these parts.

1.1.2 Connection of the machine

Before connecting the machine to the mains, check the correct setting of the line voltage. For the connection of sensor, applicators e.g. see the chapter connections. Fix all cables to prevent accidents and damaging of cables. Have also a look to the EMI chapter for proper machine operation.

For checking of correct operation of sensors, applicators use the check functions SCHK, I_CH and O_CH.

1.1.3 General setting

Normally the setting is done, but before operation check and note the general dispenser configuration: dispenser direction, machine type, applicator mode, and APSF function.

Release 11/05

Page 17

Preparing the machine

Image 19
Contents Page Page ALS Menu structure Errors and warnings Copyright Important NotesOverview ManufacturerGeneral Safety Notes SafetyOperator’s duty of care Concrete security regulations and symbols used Security measures during normal operation Security measures during maintenance and repairsWork on pneumatic equipment Work on the electrical equipmentObserve environmental regulations Page Mechanics DescriptionDispensing mechanics Operator panel Operator panelALS Electronic Plug boardALS Unpacking of the unit InstallationGeneral setting Preparing the machineInsert material Prepare dispensingDefine label data Manual adjustment of the Cont parameter Setting Lpit manuallyCapacitive label sensor Capacitive sensor Label guideStop position Adjust dispense functionFixed dispensing speed Label position on the product Automatic dispensing speed ApsfProduct data bank Operation Safety recommendationLeft hand version Inserting label material3Initialise new label material Missing label function and web breaks Function Display message Mains switch4Control of dispense unit Dispenser Menu selectionLabel positionPOS Dispenser active onDispenser stopped OFF Material initialisation InitLabel position Stop position StodProduct menu PD0n Start delaySTADDispense speed Velo Blow on time BlowMaintenance Extended standard menu Configuration menuMenu structure Standard menuExtended menu ConfigurationStandard menu  Direct ApplicatorInitialisation Init Standard menuDisplay Function Values Dispensing speed Velo Start delay StadLabel position POS Labelling time BlowDisplay Function Data value Extended standard menuLabel contrast Label pitch LpitSensor status Sens Product length Prdl Dwell time APT1 Electronic gear ratio adjustment EgraEgra value check Stst Slew speed SlewBlow on time APT2 Restart delay APT3Time constant compensation APT4 Load data bank Load End of air stream signal AstpPrinter dwell time PDT Save parameter in data bank SaveProduct menu Release 11/05 Menu structure Possible tests ConfigurationPossible adjustments Calling the configuration menuDisplay Function of the parameter Possible data entry Handling the menuMenu functions Type of applicator Appl Automatic product speed followerAPSFOutput check OCH Input and sensor check ICHAdditional functions in the standard menu Number of stop bits Sbit Adjustment resettingFACTInterface baud rate Baud Parity bit PariLabel counter Labc Number of data bits DbitRecycle simulates max labels/min Recy Distance sensor to dispensing edge DistRelease 11/05 Configuration Data of the serial interface Serial interfaceCommand Description Range Interface commandsExample Ledg Message in display Bit definition in error flagError number Error message in display Error description Bit definition in warning flagOutput signals Connections and signalsApplicator modes Signals for direct dispenseTiming ASA applicator Control signals for the ASA applicatorAPT2 Signals for the EP applicatorApplicator connector Applicator connectorConnecting NPN left or PNP right inputs Input signalsProduct sensor Example for connecting an NPN sensor DatalogicNPN connection of optional ODC sensor OD Control sensorConnection of a NPN type Apsf sensor Apsf sensorOptional connector for process contro Control signalsInternal I/O connector Rule EMIWiring diagram Electronic diagramsLayout dispenser electronic board Jumper position has to be 800 steps Page Message Meaning How to solve Errors and warningsDispenser error messages STO! Power-fail messageInto Eeprom Dispenser warningsALS Technical Information Technical SpecificationDescription Details APSF- Sensor Specification Optional function Application specificationLabels per minute in relation to different label pitches Performance375 125 875 625 ALS Page Function Factory Application AdjustmentFunction PD05 PD06 PD07 PD08 PD09 Function Factory PD01 PD02 PD03 PD04Siehe Machine type Index