Avery ALS 230 manual Als

Page 18

Operators Manual

ALS 230

Release 11/05

Page 16

Description

Image 18
Contents Page Page ALS Menu structure Errors and warnings Manufacturer Important NotesOverview CopyrightSafety General Safety NotesOperator’s duty of care Concrete security regulations and symbols used Security measures during maintenance and repairs Security measures during normal operationWork on the electrical equipment Work on pneumatic equipmentObserve environmental regulations Page Description MechanicsDispensing mechanics Operator panel Operator panelALS Plug board ElectronicALS Preparing the machine InstallationGeneral setting Unpacking of the unitPrepare dispensing Insert materialDefine label data Setting Lpit manually Manual adjustment of the Cont parameterCapacitive label sensor Label guide Capacitive sensorAdjust dispense function Stop positionFixed dispensing speed Automatic dispensing speed Apsf Label position on the productProduct data bank Safety recommendation OperationInserting label material Left hand version3Initialise new label material Dispenser Menu selection Function Display message Mains switch4Control of dispense unit Missing label function and web breaksMaterial initialisation Init Dispenser active onDispenser stopped OFF Label positionPOSStop position Stod Label positionBlow on time Blow Start delaySTADDispense speed Velo Product menu PD0nMaintenance Standard menu Configuration menuMenu structure Extended standard menuApplicator ConfigurationStandard menu  Direct Extended menuStandard menu Initialisation InitDisplay Function Values Labelling time Blow Start delay StadLabel position POS Dispensing speed VeloExtended standard menu Display Function Data valueLabel pitch Lpit Label contrastSensor status Sens Product length Prdl Slew speed Slew Electronic gear ratio adjustment EgraEgra value check Stst Dwell time APT1Restart delay APT3 Blow on time APT2Time constant compensation APT4 Save parameter in data bank Save End of air stream signal AstpPrinter dwell time PDT Load data bank LoadProduct menu Release 11/05 Menu structure Calling the configuration menu ConfigurationPossible adjustments Possible testsHandling the menu Display Function of the parameter Possible data entryMenu functions Automatic product speed followerAPSF Type of applicator ApplInput and sensor check ICH Output check OCHAdditional functions in the standard menu Parity bit Pari Adjustment resettingFACTInterface baud rate Baud Number of stop bits SbitDistance sensor to dispensing edge Dist Number of data bits DbitRecycle simulates max labels/min Recy Label counter LabcRelease 11/05 Configuration Serial interface Data of the serial interfaceInterface commands Command Description RangeExample Ledg Bit definition in warning flag Bit definition in error flagError number Error message in display Error description Message in displayConnections and signals Output signalsSignals for direct dispense Applicator modesControl signals for the ASA applicator Timing ASA applicatorSignals for the EP applicator APT2Applicator connector Applicator connectorInput signals Connecting NPN left or PNP right inputsExample for connecting an NPN sensor Datalogic Product sensorOD Control sensor NPN connection of optional ODC sensorApsf sensor Connection of a NPN type Apsf sensorControl signals Optional connector for process controInternal I/O connector EMI RuleElectronic diagrams Wiring diagramLayout dispenser electronic board Jumper position has to be 800 steps Page STO! Power-fail message Errors and warningsDispenser error messages Message Meaning How to solveInto Dispenser warnings EepromALS Technical Specification Technical InformationDescription Details Application specification APSF- Sensor Specification Optional functionPerformance Labels per minute in relation to different label pitches375 125 875 625 ALS Page Adjustment Function Factory ApplicationFunction Factory PD01 PD02 PD03 PD04 Function PD05 PD06 PD07 PD08 PD09Index Siehe Machine type