Operators Manual
ALS 230
8.2.3Signals for the EP applicator
For controlling the applicator the signals air stream, cylinder valve and blow on are necessary. After a product signal has occurred the labelling cylinder valve is switched active after the delay STAD. However if at this time the applicator is not in the home position then error message E__2 is generated. After the delay time APT1 the blow on valve is switched active for the time APT2.
When APT2 is completed both the labelling cylinder valve and the blow on valve signals are switched inactive. If the control does not read the home position in the time given - 3* (APT1+ APT2) - than the error message E__2 is generated.
Productstart |
|
|
Homeswitch |
|
|
Cylinder valve | STAD | APT1 |
|
|
STAD
1
STAD
2
3
STAD
Blowon valve | APT2 | APT1 |
|
|
4 * (APT1 + APT2)
Dispense label | APT3 |
|
|
+ Airstream valve |
|
| |
|
|
|
1Missing Label: Labeller not ready for dispense
2Error: Homeposition not detected
3Error: Applicator not in homeposition
Figure 12 Timing EP applicator
Release 11/05 | Page 58 | Connections and signals |