APC 6000 installation manual Contents

Page 3

Contents

Characteristics

 

Characteristics common to all cubicles

4

Rectifier-inverter cubicles

5

Static Switch cubicles

5

External maintenance bypass cubicles

5

"Pack Advance" cubicles

5

Electrical parameters for selecting protective devices

6

Electrical parameters for determining cable cross-sections

7

Heat losses

7

Installation

 

Handling

10

Positioning the cubicles

10

Floor loads

11

Cubicle layout

11

Power circuit wiring diagrams

12

Connection of power circuits

16

Connection of "Media Contacts 9" standard auxiliary circuits

26

Connections between cubicles

27

Connections between rectifier-inverter cubicles and external maintenance bypass

 

cubicle

29

Connection of "Media Contacts 15" additional auxiliary circuits

30

Connection of the battery "Temperature Monitor"

31

Connection of the LED remote indications unit

33

Connection of "Tele Monitor" remote control and indication unit

33

Link to an IBM AS/400computer

33

Final installation steps

34

Appendix

 

Mains 2 line protection

35

Cubicle mounting and connection for 600kVA UPSs

36

Cubicle mounting and connection for 2000kVA Static Switch Cubicles

40

Details of earthing connections in the various cubicles

43

All MGETM GalaxyTM 6000 products are protected by patents. They implement original APC by Schneider Electric technology not available to other manufacturers.

To take into account evolving standards and technology, equipment may be modified without notice. Indications concerning technical characteristics and dimensions are not binding unless confirmed by APC by Schneider Electric.

This document may be copied only with the written consent of APC by Schneider Electric. Authorized copies must be marked "APC by Schneider Electric MGETM GalaxyTM 6000 Installation Manual nr 6739381EN".

: IBM AS/400 is a registered trademark of the International Business Machines Corporation.

6739381EN/

Image 3
Contents Mgetm GalaxyTM 2 6739381EN/JD Contents Characteristics common to all cubicles CharacteristicsPack Advance cubicles Static Switch cubiclesExternal maintenance bypass cubicles Rectifier-inverter cubiclesElectrical parameters for Mains 2 Electrical parameters for selecting protective devicesElectrical parameters for Mains RemarkHeat losses Electrical parameters for determining cable cross-sectionsLine current Mm2 KVA Inverters Amps Copper Aluminium Installation with parallel frequency convertersInstallation with parallel UPSs with a centralised SSC Number Total UPSNumber Total UPS Mains 2 or load Line currentKVA Inverters Amps Copper Front HandlingPositioning the cubicles Side clearances provided by the spacing uprights RearCubicle footpads Rear Layout for a single-unit UPS with one battery cubicleFloor loads figure Cubicle layout on false floor or normal floor figures 6, 7Rectifier-inverter cubicle Power circuit wiring diagramsConnection via the top Special caseExample of a 2 parallel UPS rectifier-inverters with SSC Diagram for a frequency converter with batteriesDiagram for a frequency converter without batteries Static Switch CubicleModular UPS cubicle External maintenance bypass cubicle Connection of power circuits GeneralCross-section AA KVA single-unit UPS cubicles see the appendix 160kVA to 400kVA modular UPS rectifier-inverter cubicle600kVA parallel UPS cubicles see the appendix XR2 XR5 XR3 XR6 Acpz XR4 XR7Apoz XR4 XR7 500kVA single-unit UPS rectifier-inverter cubicle600kVA single-unit UPS cubicles see the appendix Off500kVA modular UPS rectifier-inverter cubicle XM7 XR2 XR5XR4 XR7 XM5 XM133 Q1on Air admission Mains 1, load BatteryL1L2 L3 L1 L2 L3 Mains Battery Load XR1 XR8XR3 XR4 XR7 500/800kVA Static Switch CubicleFront Rear XR9 XR2 Q4SXR3 XR5 XR2 XR9 XR1 XR8 1200kVA Static Switch CubicleFront view XR7 XR4 UPS XR6Block XR1 Important noteAuxiliary TerminalKey to figure 1200kVA external maintenance bypass cubicleXR1 XR2 XR3 XR4 Connection of auxiliary circuits on the remote relay boardConnections between Apoz boards Connection to battery circuit breaker QF1Connections between cubicles Emergency shutdownMisi Connections between Misi boards modular UPSsXM XM XM XM XM XM 127 128 129 130 131Misi XR8 XR9 XR5 XR6 XR7 Acpz board of the Static Switch CubicleConnections Connection of the battery Temperature Monitor optionalInstalling the Temperature Monitor in a battery cubicle Temperature Monitor installation in a APC bySchneider Electric battery cubicle Temperature Monitor installation in a battery roomConsult manual 6739388XU for further information Rauz 1 board XM098 XM097 XR11 XM096 XR10 Connector XR10Connection of the LED remote indications unit Link to an IBM AS/400→ computerAfter making the connections Final installation stepsConfiguration of the AS/400→ Connection to the Media Contacts 9 relay boardUPS 500kVA Mains 2 line protectionRated inverter output Maximum permissible current KVA UPS 250 to 450kVACubicle mounting and connection for 600kVA UPSs Cubicle mountingInternal connections between cubicles Left cubicle of 600kVA single-unit or parallel UPS with SSC Connection of power and auxiliary circuitsRight cubicle of a 600kVA single-unit UPS XR2 XR5 XR3 XR6 XR4 XR7Mains Load L1 L2 L3 Air Admission Right cubicle of a 600kVA parallel UPS with SSC Air admission LoadXR3 XR6 XR4 Card cage Left cubicleRight cubicle Q3BP XF1-XF2 XM1-XM2Mains Off Right cubicle of a 2000kVA Static SwitchCross-section AA Front view Air admission Air extractionLeft cubicle of a 2000kVA Static Switch XR6 XR3 XR5 XR2XR9 XR1 XR8 Inverter input Details of earthing connections in the various cubicles250 to 400kVA rectifier-inverter cubicle 450 500kVA rectifier-inverter cubicle120 to 1200kVA Static Switch Cubicles 600kVA rectifier-inverter cubicleInverter Input Tele Monitor unit 2000kVA Static Switch CubiclesTele-Monitor unit Connection with Bolt, nut andmains 2 contact washer6739381ENPage 46 --JD6739381EN/JD
Related manuals
Manual 38 pages 11.72 Kb