Installing Network Drivers
Manual Installation
For manual driver installation
1Make sure that the system is clean.
■Type load forcnfg to remove the adapters.
■Load the INETCFG utility to delete all EMPCI boards.
■Remove all load and bind commands related to EMPCI from the sys:system\autoexec.ncf as well as the sys:etc\failover.ncf line in the autoexec.ncf file.
2Copy these files, empci.ldi, empci.lan, cdtdim.lan, failmib.lan to the sys:system directory of the NetWare server from the installation diskette to the sys:system directory of the NetWare Server.
3Edit the autoexec.ncf file manually, including the correct load and bind commands. A sample set of load and bind commands follows.
■Load command for TCP/IP protocol (not needed if TCP/IP is not used)
LOAD TCPIP
■Load command for PRIMARY; B_INDEX indicates Backup INDEX Number.
LOAD EMPCI NAME=PRIMARY_E82
FRAME=ETHERNET_802.2 INDEX=1 B_INDEX=2
■Load command for BACKUP; P_INDEX indicates primary INDEX Number.
LOAD EMPCI NAME=BACKUP_E82 FRAME=ETHERNET_802.2 INDEX=2 P_INDEX=1
■Bind command for PRIMARY, there is no bind command for BACKUP.
BIND IPX PRIMARY_E82 NET=101
■Load command for DMI agent (except FAILOVER)
LOAD CDTDMI
PCI Ethernet and Fast Ethernet Adapters User’s Guide
Stock Number: | Page: |
Print Spec Number: |
|
Current Date: 5/5/97 | ECN Date: 5/97 |