PCI Ethernet and Fast Ethernet Adapters
Running EMDIAG
Your Adaptec adapter is supplied with a comprehensive diagnostics program called emdiag.exe. EMDIAG resides in the root directory of the Adaptec diskette. To run EMDIAG
1Boot up to
2Type A:\EMDIAG and press Enter to start EMDIAG.
Using EMDIAG for PCI Adapters
EMDIAG for PCI adapters includes a number of startup options. These startup options allow you to specify a particular Adaptec adapter if you have more than one Adaptec adapter installed in your computer, and to override EMDIAG's default configuration settings.
The optional startup parameters for EMDIAG are:
/t: [value] Determines the number of times (in thousands) the transmitter test is run, when local or remote diagnostics is initiated.
/v: [10 or 100] Overrides cable speed AutoSensing and sets the signalling speed to be used by EMDIAG to either 10 Mbps or
100 Mbps.
/x: [thin or | Overrides connector AutoSensing and sets the connector to |
utp] | be tested by EMDIAG |
EMDIAG PCI Main Menu
There are six menu options on the EMDIAG PCI Main Menu:
■Configuration Status
■Diagnostics
■PCI Device Information
■Readme Viewer
■Technical Support Information
■Exit
PCI Ethernet and Fast Ethernet Adapters User’s Guide
Stock Number: | Page: |
Print Spec Number: |
|
Current Date: 5/5/97 | ECN Date: 5/97 |