Raven Installation Guide | Installation |
| |
|
|
Pin #/ |
|
|
Short Form | Function | Remarks |
1 | Amplifier OK | “Amplifier OK” indication output pin. When the |
AOK |
| amplifier is at normal operating conditions, this |
|
| output is in “active low “ state. When a failure |
|
| occurs, this output is changed to “open” state. |
|
| Opto isolated, open collector NPN type. See |
|
| Figure |
|
| Maximum voltage = 30 V |
|
| Maximum current = 8 mA. |
|
| “On” voltage: V OUT(On) < 0.8 V |
2 | Status output 1 | Status indication output 1. Specification as in pin |
SO1 |
| J3/1. |
3 | Status output 2 | Status indication output 2. Specification as in pin |
SO2 |
| J3/1. |
4 | Status output 3 | Status indication output 3. Specification as in pin |
SO3 |
| J3/1. |
5 | Status output | Status output return for AOK, SO1, SO2, SO3. |
SORET | return | Isolated from power input return. for details, see |
|
| Figure |
6 | Status output | Status output return for AOK, SO1, SO2, SO3. |
SORET | return | Isolated from power input return. for details, see |
|
| Figure |
Table 3-6: Connector J3
3.6.2Connecting a
Be sure to ground:
DC power common
Motor chassis
Amplifier heatsink
Do not ground the control common, which is internally connected to the power common. Grounding the control common will create a ground loop.