Raven Installation Guide
Appendix: Technical Specifications
| A.1 | Power Ratings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Feature |
| Units | 5/60 |
| 10/60 |
| 15/60 | 25/60 |
| 3/100 |
| 10/100 | 15/100 | 20/100 | 2/200 | 6/200 | 10/200 | 15/200 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Minimum supply | VDC |
|
|
| 10 |
|
|
|
| 20 |
|
| 40 |
|
| |||||
voltage |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Nominal supply | VDC |
|
|
| 50 |
|
|
|
| 85 |
|
| 170 |
|
| |||||
voltage |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Maximum supply | VDC |
|
|
| 59 |
|
|
|
| 95 |
|
| 195 |
|
| |||||
voltage |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Maximum continuous | W | 240 |
| 480 |
| 720 | 1200 | 260 |
| 800 | 1200 | 1600 | 360 | 960 | 1600 | 2400 | ||||
power output |
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Efficiency at rated | % |
|
|
|
|
|
|
|
|
| > 97 |
|
|
|
|
|
| |||
power (at nominal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
conditions) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Maximum output |
|
|
|
|
|
| Up to 100% of DC bus voltage |
|
|
|
| |||||||||
voltage |
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Sinusoidal continuous | A | 5 |
| 10 |
| 15 | 25 |
| 3.3 |
| 10 | 15 | 20 | 2.25 | 6 | 10 | 15 |
| ||
current magnitude |
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Peak current limit | A |
|
|
|
|
|
|
|
|
| 2 x Ic |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Mounting method |
|
|
|
|
|
|
|
| PCB mount |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| A.2 | Electrical Specifications |
|
|
|
|
|
|
|
|
|
|
| |||||||
| Feature |
|
|
|
|
|
|
| Details |
|
|
|
|
|
|
|
| |||
| Switching frequency on the load |
|
|
|
| 32 kHz (±5%) |
|
|
|
|
|
|
| |||||||
| Current loop bandwidth |
|
|
|
|
|
| Up to 4 kHz |
|
|
|
|
|
|
| |||||
| Current step response |
|
|
|
|
|
| <70 µsec |
|
|
|
|
|
|
|
| ||||
| Peak current duration (full rated peak current) | 2.7 sec ±15% |
|
|
|
|
|
|
| |||||||||||
| Continuous current limit tolerance |
|
|
|
|
|
|
|
|
|
|
| ||||||||
| Peak current limit tolerance |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| Current gain linearity |
|
|
|
|
|
| Better than ±1% of rated continuous current | ||||||||||||
| Current gain accuracy |
|
|
|
|
|
| Better than ±5% for 0.05 Ic < lmotor > Ip |
|
| ||||||||||
| Current monitor accuracy |
|
|
|
|
|
| Better than ±5% for 0.05 Ic < lmotor > Ip |
|
|