Siemens RDG400 manual Operation, Layout, Button operation, User action, Effect, description

Page 33

5.2Operation

See also the operating instructions B3181 enclosed with the thermostat.

Layout

 

 

 

2

 

 

1

3

 

1

 

Operating mode button / Esc

 

2

 

Protection mode and OK

 

3

 

Rotary knob for setpoint and parameter adjustment

Button operation

When the thermostat is in normal operation, the actual operating mode and

status is indicated by symbols.

When a button is pressed, the RDG goes into the Mode selection

The LCD backlight will turn on, all possible mode selection options (symbols) will turn on, indicator element (arrow) will appear on the current mode/status.

When the button is pressed again, the indicator element will toggle to the next mode symbol and so on.

After the last press and a timeout of 3 sec, the new selected mode is confirmed, the other elements disappear.

After a timeout of 20 sec the LCD backlight will turn off

User action

Press left button

Press left button >3 sec

Remain on left button and turn rotary knob clockwise

Remain on left button and turn rotary knob anti-clockwise

Press left button while "Operating mode switch-over" is activated

Press right button >3 sec

Press right button

Rotate rotary knob

Press left + right button >3sec, release, then press right button >3sec

Press left button + right button 3sec, release, press left button 3sec,

then rotate rotary knob counter-clockwise min ½ rotation

Effect, description

Go into Operating mode selection Set thermostat to Protection mode Activate temporary timer "Extend presence" and set the time (details see page 16) Activate temporary timer " Extend absence" and set the time (details see page 16) Activate " Extend Comfort mode"

(details see page 16) Activate/deactivate button lock Change to protection mode and back Adjust the room temperature setpoint Go into parameter mode Service level

Go into parameter mode Expert level, diagnostics & test

 

 

33 / 42

 

 

 

Siemens

RDG100, RDG100T, RDG110, RDG140, RDG160 Basic Documentation

CE1P3182en

Building Technologies

Handling

28 May 2009

Image 33
Contents Edition CE1P3182en 28 May Building TechnologiesTable of contents Revision history About this documentReference documents Before you startDocument use / request to the reader Features Types and featuresSummary Brief descriptionEquipment combinations Use AccessoriesOrdering SSA81 SSP81… SSB81 SSD81 SQS85…Functions Temperature controlGeneral note Described in sectionOperating modes Comfort mode Energy Saving Protection modeSetpoints Setpoints and sequence Comfort mode Energy Saving Protection mode ApplicationSingle duct With min/max Limitation Single duct With Electrical HeaterHeating mode Cooling mode Single duct Comfort mode Energy Saving mode ApplicationProtection mode Heating mode Cooling mode With heating Cooling coilApplications overview Additional features External / return air Temperature sensorFloor heating Limitation functionButton lock Sec after the last adjustmentLocked or unlocked by pressing the right button for 3 sec Comf Extension Prot Absence Not available EcoParameter P01 = Sequence Mode Sequences overview setting via parameter P01Control sequences Applications and sequencesSingle-duct heating / cooling coil Function of the control outputs is set via DIP switches 4DIP Y10 = … 10 10 … 0 V inverted PositionSingle duct Setting the sequence and the control outputsHeating or cooling Modulating control 3-position, PWM or DC 0 … 10Single duct with electrical heater SequencesModulating electrical heater Modulating radiator / floor heating Single duct with radiator or floor heatingSingle duct with heating / cooling coil Control sequenceModulating heating / cooling coil Control outputs Control output for air flowSynchronization ON/OFF control signal Position control SignalPosition actuator Parameter P44 Y1 and Y2AI/DI Multifunctional input, Digital inputDIP switches Handling of faultsTemperature out RangeParameter setting Control parametersChange the parameters as follows Service level Parameters Service levelExpert level Parameters Expert level, diagnostics & testDiagnostics & test Wiring Mounting and installationHandling MountingLayout OperationButton operation User actionLCD display DisposalConnection terminals EngineeringConnection diagrams Dimensions Mechanical designGeneral Power supply Outputs Inputs Operational data Technical dataPage Automatic heating/cooling changeover Index