Power supply

Outputs

Inputs

Operational data

8

 

 

 

Technical data

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating voltage

 

SELV AC 24 V ± 20%

 

Frequency

 

50/60 Hz

 

 

 

Power consumption

 

Max. 2 VA

 

 

 

Control output Y10-G0

 

DC 0…10 V

 

 

 

 

Resolution

 

39 mV

 

 

 

 

Current

 

Max. ± 1 mA

 

 

 

Control output Y1, Y2-G

 

AC 24 V

 

 

 

 

Rating

 

Max. 1 A

 

 

 

Multifunctional inputs

 

 

 

 

 

 

X1-M / X2-M

 

 

 

 

 

 

 

 

 

Temperature sensor input

 

QAH11.1 (NTC)

 

 

 

 

 

Type

 

 

 

 

 

 

Digital input

 

Selectable (NO/NC)

 

 

 

 

 

Operating action

 

 

 

 

 

 

Contact sensing

 

DC 0…5 V, max. 5 mA

 

 

D1-GND

 

Selectable (NO/NC)

 

 

 

 

 

Operating action

 

 

 

 

 

 

Contact sensing

 

SELV DC 6…15 V, 3…6 mA

 

 

Function input

 

Selectable

 

 

 

 

 

 

 

External temperature sensor, changeover

 

 

 

 

 

 

 

 

sensor, operating mode switchover contact,

 

 

 

 

 

 

 

 

dewpoint monitor contact, enable electrical

 

 

 

 

 

 

 

 

heater contact, fault contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switching differential, adjustable

 

2 K (0.5...6 K)

 

 

Heating mode

(P30)

 

 

Cooling mode

(P31)

1 K (0.5...6 K)

 

 

Setpoint setting and range

 

21 °C

(5...40 °C)

 

 

 

 

 

Comfort mode

(P08)

 

 

 

 

 

 

 

 

 

Energy Saving mode

(P11-P12)

15 °C/30 °C (OFF, 5...40

 

 

 

 

 

Protection

(P65-P66)

°C)

(OFF, 5...40 °C)

 

 

 

 

 

 

 

8 °C/OFF

 

Multifunctional inputs X1 / X2 / D1

 

Selectable

 

 

 

 

Input X1

 

Ext. temperature sensor

 

 

 

 

 

 

 

(P38=1)

 

 

 

 

Input X2

 

Changeover sensor

 

 

 

 

 

 

 

(P40=2)

 

 

 

 

Input D1

 

Operating mode switchover

 

 

 

 

 

 

 

(P42=3)

 

 

 

Built-in room temperature sensor

 

0…49 °C

 

 

 

 

Measuring range

 

 

 

 

 

Accuracy at 25 °C

 

< ± 0.5 K

 

 

 

 

Temperature calibration range

 

± 3.0 K

 

 

 

Settings and display resolution

 

0.5 °C

 

 

 

 

Setpoints

 

 

 

 

 

Current temperature value displayed

 

0.5 °C

 

 

38 / 42

Siemens

RDG100…/RDG110…/RDG140.../RDG160… Basic Documentation

CE1P3182en

Building Technologies

Technical data

28 May 2009

Image 38
Contents Building Technologies Edition CE1P3182en 28 MayTable of contents Reference documents About this documentRevision history Before you startDocument use / request to the reader Summary Types and featuresFeatures Brief descriptionEquipment combinations Ordering AccessoriesUse SSA81 SSP81… SSB81 SSD81 SQS85…General note Temperature controlFunctions Described in sectionComfort mode Energy Saving Protection mode Operating modesSetpoints Single duct With min/max Limitation Comfort mode Energy Saving Protection mode ApplicationSetpoints and sequence Single duct With Electrical HeaterProtection mode Heating mode Cooling mode Comfort mode Energy Saving mode ApplicationHeating mode Cooling mode Single duct With heating Cooling coilApplications overview Additional features Floor heating Temperature sensorExternal / return air Limitation functionLocked or unlocked by pressing the right button for 3 sec Sec after the last adjustmentButton lock Comf Extension Prot Absence Not available EcoControl sequences Sequences overview setting via parameter P01Parameter P01 = Sequence Mode Applications and sequencesDIP Y10 = … 10 10 … 0 V inverted Function of the control outputs is set via DIP switches 4Single-duct heating / cooling coil PositionHeating or cooling Setting the sequence and the control outputsSingle duct Modulating control 3-position, PWM or DC 0 … 10Modulating electrical heater Single duct with electrical heaterSequences Single duct with radiator or floor heating Modulating radiator / floor heatingModulating heating / cooling coil Single duct with heating / cooling coilControl sequence Synchronization Control outputsControl output for air flow ON/OFF control signal Position actuator SignalPosition control Parameter P44 Y1 and Y2Multifunctional input, Digital input AI/DITemperature out Handling of faultsDIP switches RangeChange the parameters as follows Parameter settingControl parameters Parameters Service level Service levelParameters Expert level, diagnostics & test Expert levelDiagnostics & test Handling Mounting and installationWiring MountingButton operation OperationLayout User actionDisposal LCD displayEngineering Connection terminalsConnection diagrams General DimensionsMechanical design Technical data Power supply Outputs Inputs Operational dataPage Index Automatic heating/cooling changeover