Siemens RDG400 manual Disposal, LCD display

Page 34

LCD display

17

16

15

 

14 13 12

 

 

1

 

 

 

11

 

 

2

 

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

 

 

5

 

 

 

 

 

 

6

 

 

 

6

 

 

 

 

 

 

 

 

7

8

 

9

10

#

Symbol

Description

 

# Symbol

Description

1

 

Heating mode

 

10

Confirmation of parameters

2

 

Electrical heater active

 

11

Degrees Celsius

 

 

Degrees Fahrenheit

 

 

 

 

 

3

 

Cooling mode

 

12

Digits for room temperature and setpoint

4

 

Comfort mode

 

13

Button lock active

5

 

Energy Saving mode

 

14

Condensation in room (dewpoint sensor active)

6

 

Protection

 

15

Fault

 

 

 

Escape

 

16

Temporary timer function (visible when

7

 

 

operating mode is temporarily extended

 

 

 

 

 

presence or absence)

8

 

Digits for room temperature, setpoint,

17

Indicates that room temperature is displayed

 

etc.

 

5.3Disposal

The device is classified as waste electronic equipment in terms of the European Directive 2002/96/EC (WEEE) and should not be disposed of as unsorted muni- cipal waste.

The relevant national legal rules are to be adhered to.

Regarding disposal, use the systems setup for collecting electronic waste.

Observe all local and applicable laws.

34 / 42

Siemens

RDG100…/RDG110…/RDG140.../RDG160… Basic Documentation

CE1P3182en

Building Technologies

Handling

28 May 2009

Image 34
Contents Building Technologies Edition CE1P3182en 28 MayTable of contents Reference documents About this documentRevision history Before you startDocument use / request to the reader Summary Types and featuresFeatures Brief descriptionEquipment combinations Ordering AccessoriesUse SSA81 SSP81… SSB81 SSD81 SQS85…General note Temperature controlFunctions Described in sectionComfort mode Energy Saving Protection mode Operating modesSetpoints Single duct With min/max Limitation Comfort mode Energy Saving Protection mode ApplicationSetpoints and sequence Single duct With Electrical HeaterProtection mode Heating mode Cooling mode Comfort mode Energy Saving mode ApplicationHeating mode Cooling mode Single duct With heating Cooling coilApplications overview Additional features Floor heating Temperature sensorExternal / return air Limitation functionLocked or unlocked by pressing the right button for 3 sec Sec after the last adjustmentButton lock Comf Extension Prot Absence Not available EcoControl sequences Sequences overview setting via parameter P01Parameter P01 = Sequence Mode Applications and sequencesDIP Y10 = … 10 10 … 0 V inverted Function of the control outputs is set via DIP switches 4Single-duct heating / cooling coil PositionHeating or cooling Setting the sequence and the control outputsSingle duct Modulating control 3-position, PWM or DC 0 … 10Sequences Single duct with electrical heaterModulating electrical heater Single duct with radiator or floor heating Modulating radiator / floor heatingControl sequence Single duct with heating / cooling coilModulating heating / cooling coil Control output for air flow Control outputsSynchronization ON/OFF control signal Position actuator SignalPosition control Parameter P44 Y1 and Y2Multifunctional input, Digital input AI/DITemperature out Handling of faultsDIP switches RangeControl parameters Parameter settingChange the parameters as follows Parameters Service level Service levelParameters Expert level, diagnostics & test Expert levelDiagnostics & test Handling Mounting and installationWiring MountingButton operation OperationLayout User actionDisposal LCD displayEngineering Connection terminalsConnection diagrams Mechanical design DimensionsGeneral Technical data Power supply Outputs Inputs Operational dataPage Index Automatic heating/cooling changeover