Siemens RDG400 manual Equipment combinations

Page 6

 

2.3

Equipment combinations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

 

Product no.

 

Data

 

 

 

 

 

Sheet

 

 

 

 

 

 

 

 

 

 

 

Cable temperature sensor

 

 

QAH11.1

1840

 

 

 

 

 

 

 

 

 

Room temperature sensor

 

 

QAA32

1747

 

 

 

 

 

 

 

 

 

Condensation detector / extension

 

 

QXA2000 /

1542

 

 

module

 

 

 

 

AQX2000

 

 

 

 

 

 

 

DC 0..10 V actuator

 

Electrical actuator, DC 0..10 V

 

 

SSA61...

4893

 

 

(for radiator valve)

 

 

 

 

 

 

 

 

 

 

 

 

Electrical actuator, DC 0..10 V

 

 

SSC61…

4895

 

 

(for 2 and 3 port valves / V…P45)

 

 

 

 

 

 

 

 

 

 

 

 

Electrical actuator, DC 0..10 V

 

 

SSP61…

4864

 

 

(for small valve 2,5 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Electrical actuator, DC 0..10 V

 

 

SSB61...

4891

 

 

(for small valves 5.5 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Electrical actuator, DC 0..10 V

 

 

SSD61...

4861

 

 

(for Combi-valve VPI45)

 

 

 

 

 

 

 

 

 

 

 

 

Thermal actuator, DC 0..10 V

 

 

 

 

4880

 

 

(for small valves and radiator

 

 

STS61

 

 

valves)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GQD161…

4605

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GDB161…

4634

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GLB161…

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC 0…10 V damper actuator

 

 

 

GMA161…

4614

 

 

 

 

 

 

 

 

 

 

GEB161…

4621

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GCA161…

4613

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GBB161…

4626

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GIB161…

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VAV compact controller

 

 

 

GDB181.1E/3

3544

 

 

 

 

 

 

 

 

 

GLB181.1E/3

 

 

 

 

 

 

 

 

ON/OFF actuators

 

 

 

 

 

 

 

 

Electromotoric ON/OFF valve and

 

 

 

 

 

AC 24 V

 

actuator

 

 

 

 

MVI…/MXI…

4867

 

 

(only available in AP, UAE, SA and IN)

 

 

 

 

 

 

 

Electromotoric ON/OFF actuator

 

 

SFA71...

4863

 

 

 

 

 

 

 

 

 

Thermal actuator (for radiator valve)

 

 

STA71...

4877

 

 

 

 

 

 

 

 

 

 

Thermal actuator

 

 

STP71...

4878

 

 

(for small valves 2.5 mm)

 

 

 

 

 

 

 

 

 

 

6 / 42

Siemens

RDG100…/RDG110…/RDG140.../RDG160… Basic Documentation

CE1P3182en

Building Technologies

Summary

28 May 2009

Image 6
Contents Building Technologies Edition CE1P3182en 28 MayTable of contents Reference documents About this documentRevision history Before you startDocument use / request to the reader Summary Types and featuresFeatures Brief descriptionEquipment combinations Ordering AccessoriesUse SSA81 SSP81… SSB81 SSD81 SQS85…General note Temperature controlFunctions Described in sectionComfort mode Energy Saving Protection mode Operating modesSetpoints Single duct With min/max Limitation Comfort mode Energy Saving Protection mode ApplicationSetpoints and sequence Single duct With Electrical HeaterProtection mode Heating mode Cooling mode Comfort mode Energy Saving mode ApplicationHeating mode Cooling mode Single duct With heating Cooling coilApplications overview Additional features Floor heating Temperature sensorExternal / return air Limitation functionLocked or unlocked by pressing the right button for 3 sec Sec after the last adjustmentButton lock Comf Extension Prot Absence Not available EcoControl sequences Sequences overview setting via parameter P01Parameter P01 = Sequence Mode Applications and sequencesDIP Y10 = … 10 10 … 0 V inverted Function of the control outputs is set via DIP switches 4Single-duct heating / cooling coil PositionHeating or cooling Setting the sequence and the control outputsSingle duct Modulating control 3-position, PWM or DC 0 … 10Single duct with electrical heater SequencesModulating electrical heater Single duct with radiator or floor heating Modulating radiator / floor heatingSingle duct with heating / cooling coil Control sequenceModulating heating / cooling coil Control outputs Control output for air flowSynchronization ON/OFF control signal Position actuator SignalPosition control Parameter P44 Y1 and Y2Multifunctional input, Digital input AI/DITemperature out Handling of faultsDIP switches RangeParameter setting Control parametersChange the parameters as follows Parameters Service level Service levelParameters Expert level, diagnostics & test Expert levelDiagnostics & test Handling Mounting and installationWiring MountingButton operation OperationLayout User actionDisposal LCD displayEngineering Connection terminalsConnection diagrams Dimensions Mechanical designGeneral Technical data Power supply Outputs Inputs Operational dataPage Index Automatic heating/cooling changeover