Sanyo srt-6000 Output Terminals, Tape END OUT Terminal, Timer OUT Terminal, COM Terminal

Page 36

OUTPUT TERMINALS

TAPE END OUT Terminal

œDuring recording, when the end of the tape is reached or when the tape counter reading indicates 7 hours 57 minutes or more, the output becomes 0V (Low).

œTo reset the output, press the STOP or EJECT button.

œDuring autorepeat recording, when the end of the tape is reached, the output becomes 0V (Low) for about 2 seconds only.

Tape end or 7H57M00S

Output reset

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

TAPE END OUT Terminal Output Setting

1Press the MENU button until the (SET UP 3) menu is displayed.

@@@@@@@<SET@UP@3>

öALARM@MODE@@@@@@@Y1

öALARM@DURATION@@@20S

öVERTICAL@SYNC@@@@Y

öEXT@TIME@ADJ.@@@@01:00

öTAPE@IN@MODE@@@@@STOP

öTAPE@END@MODE@@@@REW öTAPE@END@OUT@@@@@-3M öCLOG@DETECT.@@@@@Y öSERIES@REC@IN@@@@N öRS-232C@@@@@@@@@@19200

2Turn the JOG dial, until the “TAPE END OUT” setting is flashing.

3Turn the SHUTTLE ring, to select the desired output mode.

–3M . . . . . . . The output becomes 0 V (Low) when the tape counter reaches “7H57M00S” and/or when the tape reaches the end.

END . . . . . . . The output becomes 0 V (Low) when the tape reaches the end.

4Press the SEARCH button to save the setting.

WARNING OUT Terminal

œIf the tape stops or other problem, the output becomes 0V (Low).

œTo reset the output, press the STOP or ALL RESET button or unplug the power cord then plug it back in.

Tape movement stop

Output reset

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

NOTE:

œIf the output is 0V (Low) due to the clog detect function, it can be reset by simply pressing the STOP button.

TIMER OUT Terminal

œDuring timer recording DC 12 V (High) are output. (During timer recording stand-by mode, the output is 0V (Low).)

Timer recording

12V (H)

(Output impedance: 5.7 kΩ) 0V (L)

COM Terminal

œCommon GND (ground) terminal when connecting other terminals to external devices.

English

35

Image 36
Contents SRT-6000 Precautions Features AccessoryContents Counter Reset button Front PanelTRACKING/V. Still or + button Search buttonLocations of Controls and Indicators Operation IndicatorsOperation Mode Indicator OFF indicatorBack Panel RS485 BPower Cord Installation About the memory resetConnections Types of ON-SCREEN Displays and Display Sequence Reference pages are shown in square bracketsUsing the JOG dial and Shuttle ring Types of ON-SCREEN Displays and Display SequenceJOG dial Shuttle ringSetting the Language and Clock Setting procedure is now completedDay of week is set automatically Last 2 digits only are displayedChanging the ON-SCREEN Display Selecting the On-screen DisplayChanging the Date/Time Display Position Date and time are displayedVideo Cassette Tapes Setting the Action to Take When a Cassette is Loaded Video Cassette TapesCorrect tape thread check function Recording Speed Mode Normal RecordingNormal Recording Before starting Record PauseChanges to the Recording Speed Mode During Recording Action to Take when the Video Signal DeterioratesNormal Recording Concerning the Number of Times Tapes can be Rerecorded onRecording Check Clog DetectionSetting the Mode at the End of the Tape Repeat indicator will lightAlarm Mode setting is flashing Autorepeat RecordingAlarm Recording Alarm Recording SettingAlarm Recording Alarm Recording Counter DisplayConnections to the Alarm IN/OUT Terminals Checking the Alarm Recordings TimeAlarm Search Alarm ScanProgram Timer Recording Recording will not take placeProgram Timer Recording Day of the week of the 8th line is flashingSetting the Holidays Changing a Program Timer RecordingTo Cancel a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording Using AN External Timer Input Series Recording Setup Repeat REC switchSeries Recording Series recording connectionsContinous Loop Recording Setup Series RecordingLoop recording connection example with 2 VCRs Normal Playback Special Playback Special Playback Day/Time SearchShuttle Ring Operation D Search 01 0000 will be displayed on screenSetting the Security Lock Counter will be reset to 0H 00M 00STape Counter Is displayed on the digital displaySetting the Buzzer Clock AdjustmentSetting procedure on the first VCR is now completed Setting the Cassette Eject Mode Cassette Eject SetupEject terminal connection Eject in terminalSetting the RS-232C or RS-485 Data Transfer Speed DIP Switches SetupData Transfer Speed Setup Setting the RS-232C or RS-485 Data Transfer Speed RS485 RJ-11 connector layoutConnector a Connector B Signal RS-485 ConnectionTimer OUT Terminal Tape END OUT Terminal Output SettingOutput Terminals Tape END OUT TerminalSeries OUT/NON REC OUT terminal setting SW OUT Terminal Output SettingField or Frame setting is flashing Output TerminalsRemote control setting Remote JackMaintenance Maintenance Maintenance TableMaintaining and Checking The Mechanism Troubleshooting Guide After a Power FailureSystem Down Specifications Sanyo Industrial VCR Warranty Weekdays 830 AM 500 PM Pacific TimeRC4QR/U2