Sanyo srt-6000 Output Terminals, SW OUT Terminal, Series OUT/NON REC OUT terminal setting

Page 37

OUTPUT TERMINALS

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT terminal.

This terminal is usually connected to the switch input (SW IN) of devices like a camera switcher unit, or a quad compressor.

FIELD: 16.7 msec.

FRAME: 5 msec.

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

SW OUT Terminal Output Setting

1Press the MENU button until the (SET UP 4) menu is displayed.

øThe FIELD (or FRAME) setting is flashing.

@@@@@@@<SET@UP@4>

öSW@OUT

@@FIELD@@@@@@@@@01

@@TIMING@@@@@@@@FIELD

@@8H@@@@@@@@@@@@Y

öTHREAD@CHECK@@@Y

öVIDEO@LOSS@@@@@N

öREC@SPEED@@@@@@N

öEJECT@SET

@@EJECT@MODE@@@@EJECT1

@@OPERATION@@@@@SLAVE

NOTE:

œIf “TIMING” is set to FRAME (see step 4), “FRAME” will be indicated instead of “FIELD”.

2Turn the SHUTTLE ring, to set the desired pulse signal interval.

Available settings are:

FIELD. . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field

FRAME . . . . 01, 02, 03, 04, 05, 10, 30 or 60 frame

3Turn the JOG dial clockwise until the “TIMING” setting is flashing.

4Turn the SHUTTLE ring, to set “FIELD” or “FRAME”.

FIELD. . . . . . 1 pulse is output after each set number of fields.

FRAME . . . . 1 pulse is output after each set number of frames.

5Turn the JOG dial clockwise until the “8H” setting is flashing.

NOTE:

œIf the TAPE SELECT switch to the “T-120”, “6H” will be indicated instead of “8H”.

6Turn the SHUTTLE ring, to set the desired “8H” mode.

Y. . . . . . . . . . When recording in 8-hour mode, a pulse signal is output.

N. . . . . . . . . When recording in 8-hour mode, a pulse signal is not output.

7Press the SEARCH button to save the settings.

SERIES OUT/NON REC OUT terminal setting

The output at the SERIES OUT/NON REC OUT terminal can be set.

1Press the MENU button until the (SET UP 1) menu is displayed.

@@@@@@@<SET@UP@1>

öDAYLIGHT@SET@@@@@USE

@@@@@@@@WEEK@MONTH@TIME

@ON@@@1ST-SUN@@04@02:00 @OFF@@LST-SUN@@10@02:00 öOUTPUT@@@@@@@@SERIES öCLOCK@SET @10-15-99@FRI@@15:20:00 öREMOTE@@@@@@@@EJECT öLANGUAGE-LANGUE-IDIOMA

@@@ENGLISH

2Turn the JOG dial, until the “OUTPUT” setting is flashing.

3Turn the SHUTTLE ring, to select the desired output mode.

SERIES . . . . If during series recording, the counter reading reaches

7H57M00S or the tape reaches the end, a LOW signal (0 V) is output. The LOW (0 V) signal is output for about 70 seconds after the end of the tape is reached.

NON REC . . If during recording the VCR enters a mode other than recording (i.e. recording pause, stop mode, etc.), a LOW signal (0 V) is output. If recording is resumed, then a HIGH signal (5 V) is output.

If in the (SET UP 2) menu, in the BUZZER section, WARNING is set to “Y”, a buzzer will be heard while the VCR is in non recording mode. The buzzer will stop if the STOP button is pressed (the output signal will remain LOW (0 V)).

4Press the SEARCH button to save the setting.

36

English

Image 37
Contents SRT-6000 Precautions Accessory FeaturesContents Front Panel Counter Reset buttonTRACKING/V. Still or + button Search buttonOperation Indicators Locations of Controls and IndicatorsOperation Mode Indicator OFF indicatorRS485 B Back PanelAbout the memory reset Power Cord InstallationConnections Reference pages are shown in square brackets Types of ON-SCREEN Displays and Display SequenceTypes of ON-SCREEN Displays and Display Sequence Using the JOG dial and Shuttle ringJOG dial Shuttle ringSetting procedure is now completed Setting the Language and ClockDay of week is set automatically Last 2 digits only are displayedSelecting the On-screen Display Changing the ON-SCREEN DisplayChanging the Date/Time Display Position Date and time are displayedVideo Cassette Tapes Video Cassette Tapes Setting the Action to Take When a Cassette is LoadedCorrect tape thread check function Normal Recording Recording Speed ModeNormal Recording Before starting Record PauseAction to Take when the Video Signal Deteriorates Changes to the Recording Speed Mode During RecordingNormal Recording Concerning the Number of Times Tapes can be Rerecorded onClog Detection Recording CheckRepeat indicator will light Setting the Mode at the End of the TapeAlarm Mode setting is flashing Autorepeat RecordingAlarm Recording Setting Alarm RecordingAlarm Recording Counter Display Alarm RecordingConnections to the Alarm IN/OUT Terminals Checking the Alarm Recordings TimeAlarm Scan Alarm SearchRecording will not take place Program Timer RecordingDay of the week of the 8th line is flashing Program Timer RecordingChanging a Program Timer Recording Setting the HolidaysTo Cancel a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording Using AN External Timer Input Repeat REC switch Series Recording SetupSeries Recording Series recording connectionsSeries Recording Continous Loop Recording SetupLoop recording connection example with 2 VCRs Normal Playback Special Playback Day/Time Search Special PlaybackShuttle Ring Operation D Search 01 0000 will be displayed on screenCounter will be reset to 0H 00M 00S Setting the Security LockTape Counter Is displayed on the digital displayClock Adjustment Setting the BuzzerSetting procedure on the first VCR is now completed Cassette Eject Setup Setting the Cassette Eject ModeEject terminal connection Eject in terminalDIP Switches Setup Setting the RS-232C or RS-485 Data Transfer SpeedData Transfer Speed Setup RS485 RJ-11 connector layout Setting the RS-232C or RS-485 Data Transfer SpeedConnector a Connector B Signal RS-485 ConnectionTape END OUT Terminal Output Setting Timer OUT TerminalOutput Terminals Tape END OUT TerminalSW OUT Terminal Output Setting Series OUT/NON REC OUT terminal settingField or Frame setting is flashing Output TerminalsRemote Jack Remote control settingMaintenance Maintenance Table MaintenanceMaintaining and Checking The Mechanism After a Power Failure Troubleshooting GuideSystem Down Specifications Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR WarrantyRC4QR/U2