Sanyo srt-6000 instruction manual Alarm Recording Setting

Page 18

ALARM RECORDING

By connecting the ALARM IN terminal to a door switch, an interphone, etc., a recording can be done only when necessary.

Alarm Recording Setting

Alarm recording is performed when there is an input (trigger) at the ALARM IN terminal, “AL” is displayed on the digital display.

œMake all necessary connections.

œFollow the Before starting steps, under “NORMAL RECORDING”.

1Set the ALARM SPEED switch to the desired recording speed.

8H . . . . . 8-hour mode recording

24H . . . . 24-hour mode recording

NC . . . . . Recording at the speed already set

2Set the ALARM DURATION switch to the desired recording duration.

20S. . . . . 20-second recording

PROG. . . Recording for the duration set for the “ALARM DURATION” item in the (SET UP 3) menu.

CC. . . . . Recording as long as the alarm signal is being input (minimum 5 seconds)

3Press the MENU button until the (SET UP 3) menu is displayed.

@@@@@@@<SET@UP@3>

öALARM@MODE@@@@@@@Y1

öALARM@DURATION@@@20S

öVERTICAL@SYNC@@@@Y

öEXT@TIME@ADJ.@@@@01:00

öTAPE@IN@MODE@@@@@STOP

öTAPE@END@MODE@@@@REW öTAPE@END@OUT@@@@@-3M öCLOG@DETECT.@@@@@Y öSERIES@REC@IN@@@@N öRS-232C@@@@@@@@@@19200

4Turn the SHUTTLE ring to set the desired alarm mode.

Y1. . . . . . Alarm recording is done when there is an alarm trigger.

Y2. . . . . . Alarm recording is done only when there is an alarm trigger during programmed timer recording.

Y3. . . . . . Alarm recording is done only if there is an alarm trigger and the VCR is not in programmed timer recording mode.

Y4. . . . . . Alarm recording is done only when there is an alarm trigger during programmed timer recording duration. Timer recording is not possible.

N. . . . . . Alarm recording is not performed even if there is an alarm trigger.

If the ALARM DURATION switch is set to the “PROG.” position, please continue with steps 5 and 6.

5Turn the JOG dial, until the “ALARM DURATION” setting is flashing.

6Turn the SHUTTLE ring, to select the desired alarm recording duration (20S, 40S, 1M, 2M, 3M, 4M, 5M, or CC).

20S-5M. . Recording only for the displayed duration

CC. . . . . Recording as long as the alarm signal is being input (minimum 5 seconds)

7Press the SEARCH button to save the settings.

øThe setting procedure is now completed.

NOTES:

œDuring alarm recording all buttons are disabled.

œIf “OFF” is displayed on the digital display, alarm recording is not possible in order to prevent the recorded tape to be recorded over.

To cancel the “OFF” display, press the STOP, EJECT or PLAY button or turn the SHUTTLE ring.

œIf an alarm trigger is received while alarm recording is in progress, recording duration for the second alarm will be calculated from that point. The alarm counter will register the alarm, but it will not be found during an alarm scan and alarm search.

œIf there is a power failure during alarm recording, and the power is restored within the recording set duration, alarm recording will continue.

œIf the alarm recording duration is short, the alarms may not be found during an alarm scan or an alarm search. If the alarms are going to be reviewed using alarm scan or alarm search, then in 8-hour mode, 20-second or more recording duration should be used.

œTo do alarm recording during series recording, set “ALARM MODE” to “Y1” or “Y3”. Alarm recording will be conducted only if the VCR is recording.

English

17

Image 18
Contents SRT-6000 Precautions Features AccessoryContents TRACKING/V. Still or + button Counter Reset buttonFront Panel Search buttonOperation Mode Indicator Locations of Controls and IndicatorsOperation Indicators OFF indicatorBack Panel RS485 BPower Cord Installation About the memory resetConnections Types of ON-SCREEN Displays and Display Sequence Reference pages are shown in square bracketsJOG dial Using the JOG dial and Shuttle ringTypes of ON-SCREEN Displays and Display Sequence Shuttle ringDay of week is set automatically Setting the Language and ClockSetting procedure is now completed Last 2 digits only are displayedChanging the Date/Time Display Position Changing the ON-SCREEN DisplaySelecting the On-screen Display Date and time are displayedVideo Cassette Tapes Setting the Action to Take When a Cassette is Loaded Video Cassette TapesCorrect tape thread check function Normal Recording Before starting Recording Speed ModeNormal Recording Record PauseNormal Recording Changes to the Recording Speed Mode During RecordingAction to Take when the Video Signal Deteriorates Concerning the Number of Times Tapes can be Rerecorded onRecording Check Clog DetectionAlarm Mode setting is flashing Setting the Mode at the End of the TapeRepeat indicator will light Autorepeat RecordingAlarm Recording Alarm Recording SettingConnections to the Alarm IN/OUT Terminals Alarm RecordingAlarm Recording Counter Display Checking the Alarm Recordings TimeAlarm Search Alarm ScanProgram Timer Recording Recording will not take placeProgram Timer Recording Day of the week of the 8th line is flashingTo Cancel a Program Timer Recording Setting the HolidaysChanging a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording Using AN External Timer Input Series Recording Series Recording SetupRepeat REC switch Series recording connectionsContinous Loop Recording Setup Series RecordingLoop recording connection example with 2 VCRs Normal Playback Special Playback Shuttle Ring Operation Special PlaybackDay/Time Search D Search 01 0000 will be displayed on screenTape Counter Setting the Security LockCounter will be reset to 0H 00M 00S Is displayed on the digital displaySetting the Buzzer Clock AdjustmentSetting procedure on the first VCR is now completed Eject terminal connection Setting the Cassette Eject ModeCassette Eject Setup Eject in terminalSetting the RS-232C or RS-485 Data Transfer Speed DIP Switches SetupData Transfer Speed Setup Connector a Connector B Signal Setting the RS-232C or RS-485 Data Transfer SpeedRS485 RJ-11 connector layout RS-485 ConnectionOutput Terminals Timer OUT TerminalTape END OUT Terminal Output Setting Tape END OUT TerminalField or Frame setting is flashing Series OUT/NON REC OUT terminal settingSW OUT Terminal Output Setting Output TerminalsRemote control setting Remote JackMaintenance Maintenance Maintenance TableMaintaining and Checking The Mechanism Troubleshooting Guide After a Power FailureSystem Down Specifications Sanyo Industrial VCR Warranty Weekdays 830 AM 500 PM Pacific TimeRC4QR/U2