Sanyo srt-6000 Series Recording Setup, Series recording connections, VCR No.1 VCR No.2

Page 26

SERIES RECORDING

Using 2 VCRs or more, the series recording function lets you switch recording from one unit to the next (only with VCRs of the same model as this one).

Series Recording Setup

œConnect 2 VCRs or more as illustrated below.

œSet the TAPE SELECT switch according to the duration of the tape used.

1Press the REC/PLAY SPEED l (or j) button to set the recording speed mode.

2Set the following items as indicated.

Item

VCR No.1

VCR No.2

 

 

and on

Cassette tape

Loaded

Loaded

 

 

 

Operation mode

Stop

Stop

 

 

 

REPEAT REC switch

OFF

OFF

 

 

 

Counter memory

Canceled

Canceled

 

 

 

“OUTPUT” (in (SET UP

SERIES

SERIES

1) menu)

 

 

“SERIES REC IN” (in

Y (YES)

Y (YES)

(SET UP 3) menu)

 

 

 

 

 

Timer recording

OFF (not set)

OFF (not set)

 

 

 

Security lock

Canceled

Set

3Press the REC button on VCR No.1.

øRecording will start in series recording mode.

4Set the security lock on VCR No.1.

Series recording connections

Video camera

The SERIES OUT signal will be presence either at the point when the counter reading is 7H57M00S or when VCR No. 1 reaches the end of the tape, whichever is first. The signal will stop 70 seconds after the tape end point of VCR No. 1.

When this signal is received by VCR No. 2, it will start recording. During the period when the SERIES OUT signal is being received by VCR No. 2, if the STOP button of VCR No. 2 is accidentally pressed, VCR No. 2 will go into the stop mode for an instant and then return to the record mode.

To prevent this form occuring, the security lock of VCR No. 2 should be set to the on condition.

If TAPE END MODE is set to “REW”, when the end of the tape is reached “OFF” is displayed, the tape is rewound then stops.

NOTES:

œIf the counter reading on VCR No.1 is 7H57M00S or more, when the REC button is pressed (step 3), the recording will start on VCR No.2.

œIf in the (SET UP 3) menu “SERIES REC IN” is set to “N” and in the (SET UP 1) menu “OUTPUT” is set to “NON REC”, series recording will not be possible.

œThe counter must start from the beginning of tape, or the series recording out will not function properly.

œEven if “OFF” is displayed, series recording will be conducted if there is an input at the SERIES IN terminal.

Monitor TV

To VIDEO OUT jack (VCR)

 

 

To

VCR No.1

 

VIDEO IN

 

jack

A RS485

B

 

OFF

232 OFF

PUSH

OPEN

 

 

AUDIO

VIDEO

REMOTE

MIC IN

IN

OUT

IN

OUT

AC IN ~

 

 

 

 

 

RS232C

 

 

 

 

 

To

VIDEO OUT jack

To

SERIES OUT To COM

terminal terminal

 

 

 

 

 

 

To

 

VCR No.2

 

 

 

 

 

VIDEO IN

 

 

 

 

 

 

jack

 

A RS485

B

 

 

 

 

 

 

OFF

 

OFF

 

 

 

PUSH

 

232

 

 

 

OPEN

 

 

 

 

 

AUDIO

VIDEO

 

 

 

REMOTE

MIC IN

IN OUT

IN

OUT

 

AC IN ~

 

 

 

 

 

 

 

RS232C

 

 

 

 

 

 

 

 

 

To

 

 

 

 

SERIES OUT

 

 

 

 

 

 

terminal

 

 

To

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO OUT

 

 

To

 

 

 

jack

 

SERIES IN

 

 

 

 

 

terminal

 

 

 

 

 

 

 

 

 

 

 

 

To

 

 

 

 

 

 

 

VIDEO IN

 

 

 

 

 

To COM

jack

 

 

 

 

 

terminal

(VCR No. 3)

To COM terminal (VCR No. 3)

To SERIES IN terminal (VCR No. 3)

English

25

Image 26
Contents SRT-6000 Precautions Contents FeaturesAccessory TRACKING/V. Still or + button Counter Reset buttonFront Panel Search buttonOperation Mode Indicator Locations of Controls and IndicatorsOperation Indicators OFF indicatorBack Panel RS485 BConnections Power Cord InstallationAbout the memory reset Types of ON-SCREEN Displays and Display Sequence Reference pages are shown in square bracketsJOG dial Using the JOG dial and Shuttle ringTypes of ON-SCREEN Displays and Display Sequence Shuttle ringDay of week is set automatically Setting the Language and ClockSetting procedure is now completed Last 2 digits only are displayedChanging the Date/Time Display Position Changing the ON-SCREEN DisplaySelecting the On-screen Display Date and time are displayedVideo Cassette Tapes Correct tape thread check function Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes Normal Recording Before starting Recording Speed ModeNormal Recording Record PauseNormal Recording Changes to the Recording Speed Mode During RecordingAction to Take when the Video Signal Deteriorates Concerning the Number of Times Tapes can be Rerecorded onRecording Check Clog DetectionAlarm Mode setting is flashing Setting the Mode at the End of the TapeRepeat indicator will light Autorepeat RecordingAlarm Recording Alarm Recording SettingConnections to the Alarm IN/OUT Terminals Alarm RecordingAlarm Recording Counter Display Checking the Alarm Recordings TimeAlarm Search Alarm ScanProgram Timer Recording Recording will not take placeProgram Timer Recording Day of the week of the 8th line is flashingTo Cancel a Program Timer Recording Setting the HolidaysChanging a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording Using AN External Timer Input Series Recording Series Recording SetupRepeat REC switch Series recording connectionsLoop recording connection example with 2 VCRs Continous Loop Recording SetupSeries Recording Normal Playback Special Playback Shuttle Ring Operation Special PlaybackDay/Time Search D Search 01 0000 will be displayed on screenTape Counter Setting the Security LockCounter will be reset to 0H 00M 00S Is displayed on the digital displaySetting procedure on the first VCR is now completed Setting the BuzzerClock Adjustment Eject terminal connection Setting the Cassette Eject ModeCassette Eject Setup Eject in terminalData Transfer Speed Setup Setting the RS-232C or RS-485 Data Transfer SpeedDIP Switches Setup Connector a Connector B Signal Setting the RS-232C or RS-485 Data Transfer SpeedRS485 RJ-11 connector layout RS-485 ConnectionOutput Terminals Timer OUT TerminalTape END OUT Terminal Output Setting Tape END OUT TerminalField or Frame setting is flashing Series OUT/NON REC OUT terminal settingSW OUT Terminal Output Setting Output TerminalsRemote control setting Remote JackMaintenance Maintaining and Checking The Mechanism MaintenanceMaintenance Table System Down Troubleshooting GuideAfter a Power Failure Specifications Sanyo Industrial VCR Warranty Weekdays 830 AM 500 PM Pacific TimeRC4QR/U2