Klark Teknik DN9344E specifications Quick Reference, DN9340E Front Panel

Page 13

Quick Reference

1.QUICK REFERENCE

1.1. DN9340E Front Panel

1

2

3

4

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

7

 

8

 

9

 

 

10

 

11

 

12

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

Access buttons

Access buttons to control each type of equalisation –

 

 

 

 

 

 

 

 

 

 

GRAPHIC, PARAMETRIC, DYNAMIC, FILTERS. Press the HOME

 

 

 

 

 

 

 

 

(SETUP) button (11) to return to the home page.

 

 

 

2

 

 

 

EQ active LEDs

These show if a particular type of EQ is currently affecting

 

 

 

 

 

 

 

 

the overall frequency response.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3Main graphic display This shows the frequency response of the selected type of EQ, or the overall response on the home page.

4

Soft keys and

Select options and secondary functions as labelled on the

 

secondary function

right of main graphic display. Typically, these include Select

 

 

display

to choose a particular filter, and Menu to step round a circular

 

 

choice of options for that type of EQ. On the home page

 

 

these buttons access the gain, delay and naming functions.

5Alphanumeric display Displays menu pages for viewing/defining parameter values. and data entry knobs Values are adjusted via the left, centre, right control knobs.

6

BYPASS button

On the home page this bypasses the complete unit for the

 

 

selected channel (both channels if linked). When a

 

 

particular EQ type is selected (by the buttons above the

 

 

bypass switch), the bypass operates on that type of EQ only.

7Channel SELECT button Press to select either channel A or B for control. If the unit is linked for stereo operation then both indicators will be lit.

8Two part touch strip Press either part briefly to select a particular filter or fader. In Graphic EQ mode, press and hold to increase the level (upper strip) or reduce it (lower strip).

9

PC port

Use with the supplied cable to install software updates or to

 

STORE and RECALL

control the unit from an external computer.

 

 

 

10

Used to store complete unit settings to one of the 64

 

buttons

memory locations (32 from unit and 32 from the PC) and

 

 

 

then to recall them.

11HOME (SETUP) button

12Metering

13Power panel

Press once to return to the home page. Once on the home page, press and hold for one second to access the Setup menu. Step through the Setup menu (and exit after the last item) by repeatedly pressing this button.

Input, and Output metering incorporating multi-point clip indication.

Power switch and power ON indication.

3

Image 13
Contents DN9340E/DN9344E Page Important Safety Instructions Page Declaration of Conformity Page Contents Setup Menu DN9340E Application Notes Page Installation Considerations Safety WarningAfter Unpacking Page DN9340E Front Panel Quick ReferenceDN9344E Front Panel Key Features DN9340E & DN9344E Key FeaturesIntroducing the DN9340E/DN9344E Host Software VersionsSpace efficiency Remote control operationInterface to Midas consoles Store and Recall ParametersEQ Access and Displays Controls, Connectors, Indicators DN9340EFront Panel DN9340E Soft keys displayBypass, Channel Select, Soft Keys and Alphanumeric Display Selected channel both channels if linked. When aSoft keys Touch Strip, Store and Recall, Home Setup and Data Entry PC Port, Metering and Power Mains Rear Panel DN9340EInputs a and B Word clock InputSignal Flow DN9340E Signal Flow DN9340EOperation DN9340E Operation DN9340EHome Home page sub-menusTouchstrip Operation on the Home Soft Key Functions Graphic EqualisationEQ Flat Automatic featuresGrouping Touchstrip operation with Graphic equalisationParametric Equalisation EQ remove Touchstrip operation with Parametric equalisationLo Threshold / Level Dynamic EqualisationHi Threshold / Level Time constants Touchstrip operation with Dynamic equalisationCreate Filter function FiltersFilter Type Left Encoder Centre Encoder Right Encoder Touchstrip operation with Filters Filter settingsFilter remove Metering Clear Down Sequence Setup Menu DN9340E Setup Menu DN9340ETo access the Set Up menu pages GeneralTo switch remote communications off Remote control via a PCComms channel To select a slave remote communications channelTo select a master remote communications channel Using a DN9340E for master controlTo select a slave communications channel To remove the unit from the networkTo set a Panel Lock Front Panel lockTo remove the Panel Lock To change the input source Analogue/Digital Input SelectTo set a Presets lock Presets lockDigital Output Clock Select To select the output clock sourceDelay options LCD contrast adjustmentNaming Pages 7 To enter a nameEthernet Settings Pages 11 Power-up LogoEthernet IP Address To check and edit the Subnet Mask Ethernet Subnet Mask SetupTo store settings Using the DN9340E MemoriesTo recall settings Connections Remote ControlAddresses Data modelGetting started Setting the master unit on-lineOn a DN9340E On a DN9344EOperation To set up the namesSystem naming Copy channel function To set up the assignmentSolo Tracking operation Helix DN9340E/DN9344E unit interconnections OverviewConnecting the Helix DN9340/DN9344E units in a daisy chain Ethernet Connection Ethernet connection wireless optionEthernet connection standard Configuring the DN9344E for Network Communication Configuring the DN9340E for Network CommunicationSerial Connection Option Connection and Configuration ProcedureSerial connection details Alphanumeric displays, SETUP, Metering and Power Controls, Connectors, Indicators DN9344EPress to step through the Set Up pages Power Switch Power on Power on indication Power indicationIndicators Indicators, Up and Down Buttons, PC Port and Scribble StripsMains inlet socket Rear Panel DN9344E1B, 2A and 2B InterfaceSignal Flow DN9344E Signal Flow DN9344EOperation DN9344E Operation DN9344ERemote Comms channels To select a remote communications channel To disable remote communications and relay operation To enable the Contact Closure Relay modeTo set a password PasswordTo change the settings for Inputs 1A and 1B Analogue/Digital Input Select Pages 3Digital Output Clock Select Pages 5 To change the settings for OutputSubnet Mask Ethernet SettingsTo change the IP address To change the Subnet MaskDynamic EQ Application NotesApplication Notes Application Notes What do we mean by all these Q types? Constant Q Proportional QSymmetrical Q What is AES/EBU? 17.1. DN9340E Technical Specification DN9340EPower Requirements 17.2. DN9344E Technical Specification DN9344ERelay Socket Pin D-type rear Power Pin IEC Battery Service InformationReplacement
Related manuals
Manual 65 pages 57.17 Kb