Klark Teknik DN9344E Copy channel function, Solo Tracking operation, To set up the assignment

Page 49

Remote Control

9.7. Copy channel function

It is possible to copy a whole audio channel's settings to another channel or to multiple channels.

Note

1

Mono channels can only be copied to other mono channels, and stereo linked channels can only be copied to other stereo linked channels.

On the Master unit's Comms page, press the soft key labelled Copy Mon (to copy mono channels) or the soft key labelled Copy St (to copy stereo channels).

2Use the touchstrip to select the channel that you wish to copy from. Note that only channels of the selected type (mono or stereo) are shown.

3Press the soft key labelled Confirm to select the source channel.

4Now, the possible destination channels are shown. Use the touchstrip to select one or more channels to copy to. Once all the destination channels are selected, press the soft key labelled Confirm. The unit will display an “are you sure” message, and a final press of the Confirm soft key will start the copying process.

At any time, the copy can be aborted by pressing the HOME button.

9.8. Solo Tracking operation

Instead of selecting slaves manually from the master unit, the Helix system can be controlled from the solo system of Midas Heritage and Legend consoles. The console RS-232 port is connected to the RS-232 connector (D9) on the rear of the master DN9340E unit using a straight-wired cable (no crossovers). Once the channel assignments have been configured (see below), pressing a solo button on the console will automatically select the channel of EQ that corresponds to that console function onto the master unit, ready to be controlled.

To set up the assignment

1First select the Comms page on the master unit.

2Now press the second soft key (labelled “System”). This opens the system configuration page.

-A highlighted area shows the field that is currently being edited.

-The left encoder scrolls up and down the list of units.

-The touchstrip is used to select the column to be edited.

3The following fields can be edited:

Solo Tracking: This allows each audio channel to be associated with a type of solo

function on the Midas Heritage or Legend console. The available functions are: None, Input, Group, Aux, Matrix, Solo Clear.

Chan: This selects the particular channel solo that will be used for that channel of EQ.

So, for example, if slave EQ channel 1A is configured with Autosolo, set to Group and Chan to 5. Then pressing group solo 5 on the console will select slave EQ channel 1A onto the master Helix unit for control.

4Once all the assignments have been made, press Confirm to return to the Comms page.

39

Image 49
Contents DN9340E/DN9344E Page Important Safety Instructions Page Declaration of Conformity Page Contents Setup Menu DN9340E Application Notes Page Installation Considerations Safety WarningAfter Unpacking Page DN9340E Front Panel Quick ReferenceDN9344E Front Panel Key Features DN9340E & DN9344E Key FeaturesIntroducing the DN9340E/DN9344E Host Software VersionsSpace efficiency Remote control operationInterface to Midas consoles Store and Recall ParametersEQ Access and Displays Controls, Connectors, Indicators DN9340EFront Panel DN9340E Soft keys displayBypass, Channel Select, Soft Keys and Alphanumeric Display Selected channel both channels if linked. When aSoft keys Touch Strip, Store and Recall, Home Setup and Data Entry PC Port, Metering and Power Mains Rear Panel DN9340EInputs a and B Word clock InputSignal Flow DN9340E Signal Flow DN9340EOperation DN9340E Operation DN9340EHome Home page sub-menusTouchstrip Operation on the Home Soft Key Functions Graphic EqualisationEQ Flat Automatic featuresGrouping Touchstrip operation with Graphic equalisationParametric Equalisation EQ remove Touchstrip operation with Parametric equalisationLo Threshold / Level Dynamic EqualisationHi Threshold / Level Time constants Touchstrip operation with Dynamic equalisationCreate Filter function FiltersFilter Type Left Encoder Centre Encoder Right Encoder Touchstrip operation with Filters Filter settingsFilter remove Metering Clear Down Sequence Setup Menu DN9340E Setup Menu DN9340ETo access the Set Up menu pages GeneralTo switch remote communications off Remote control via a PCComms channel To select a slave remote communications channelTo select a master remote communications channel Using a DN9340E for master controlTo select a slave communications channel To remove the unit from the networkTo set a Panel Lock Front Panel lockTo remove the Panel Lock To change the input source Analogue/Digital Input SelectTo set a Presets lock Presets lockDigital Output Clock Select To select the output clock sourceDelay options LCD contrast adjustmentNaming Pages 7 To enter a nameEthernet Settings Pages 11 Power-up LogoEthernet IP Address To check and edit the Subnet Mask Ethernet Subnet Mask SetupTo store settings Using the DN9340E MemoriesTo recall settings Connections Remote ControlAddresses Data modelGetting started Setting the master unit on-lineOn a DN9340E On a DN9344EOperation To set up the namesSystem naming Copy channel function To set up the assignmentSolo Tracking operation Helix DN9340E/DN9344E unit interconnections OverviewConnecting the Helix DN9340/DN9344E units in a daisy chain Ethernet Connection Ethernet connection wireless optionEthernet connection standard Configuring the DN9344E for Network Communication Configuring the DN9340E for Network CommunicationSerial Connection Option Connection and Configuration ProcedureSerial connection details Alphanumeric displays, SETUP, Metering and Power Controls, Connectors, Indicators DN9344EPress to step through the Set Up pages Power Switch Power on Power on indication Power indicationIndicators Indicators, Up and Down Buttons, PC Port and Scribble StripsMains inlet socket Rear Panel DN9344E1B, 2A and 2B InterfaceSignal Flow DN9344E Signal Flow DN9344EOperation DN9344E Operation DN9344ERemote Comms channels To select a remote communications channel To disable remote communications and relay operation To enable the Contact Closure Relay modeTo set a password PasswordTo change the settings for Inputs 1A and 1B Analogue/Digital Input Select Pages 3Digital Output Clock Select Pages 5 To change the settings for OutputSubnet Mask Ethernet SettingsTo change the IP address To change the Subnet MaskDynamic EQ Application NotesApplication Notes Application Notes What do we mean by all these Q types? Constant Q Proportional QSymmetrical Q What is AES/EBU? 17.1. DN9340E Technical Specification DN9340EPower Requirements 17.2. DN9344E Technical Specification DN9344ERelay Socket Pin D-type rear Power Pin IEC Battery Service InformationReplacement