Klark Teknik DN9344E, DN9340E Front Panel lock, To set a Panel Lock, To remove the Panel Lock

Page 39

Setup Menu: DN9340E

7.3. Front Panel lock (Page 2)

This allows the front panel controls to be locked by means of an eight-character password. Four levels of Panel Lock are possible:

Unlocked – All controls available.

Lock + Recall – This leaves the Recall button active so that saved memories can be still be recalled.

Locked – Imposes a full lockout on the front panel controls, except the HOME (SETUP) button.

Function Lock – Allows you to lock the six functions, that is, graphic EQ, parametric EQ, dynamic EQ, filters, delay gain and link, in any combination.

In all cases, limited Set Up menu options remain available, namely the Comms Channel, Panel Unlock pages and Power Up pages. To unlock a unit, press HOME (SETUP) once, then press and hold HOME (SETUP) to enter the Setup menu.

To set a Panel Lock

1Step through the Set Up menu to the Panel Lock menu page.

2Use the left and centre control knobs to set a password of eight characters, including blank spaces, made up of letters, numbers and/or symbols.

Important! Preliminary and subsequent blank spaces are recorded as part of the eight-character password. Therefore, if you use a short password, the characters must be re-entered in exactly the same position to unlock the panel. To avoid confusion, either record the blanks as part of the password or enter the word at the far left of the display.

3Turn the right control knob clockwise to cycle to the required lock type.

4Press HOME (SETUP) to apply the Panel Lock.

The Home page now indicates that the unit is ‘Locked’. The lock state is retained after power down, and will be indicated on the Home page when the unit is powered up again.

To remove the Panel Lock

1Step through the Set Up menu to the Panel Lock page.

2Use the left and centre control knobs to enter the password. Note that the letters must be in the same position as when the password was set.

3Turn the right control knob clockwise to apply the password.

4If correct, the display will report ‘UNLOCKED’. Press HOME (SETUP) to exit the page and return to normal operation.

If you have entered the wrong password, the DN9340E will flag it as incorrect and return to the Panel Unlock page for a further attempt.

29

Image 39
Contents DN9340E/DN9344E Page Important Safety Instructions Page Declaration of Conformity Page Contents Setup Menu DN9340E Application Notes Page Safety Warning Installation ConsiderationsAfter Unpacking Page DN9340E Front Panel Quick ReferenceDN9344E Front Panel Host Software Versions DN9340E & DN9344E Key FeaturesKey Features Introducing the DN9340E/DN9344EStore and Recall Parameters Remote control operationSpace efficiency Interface to Midas consolesSoft keys display Controls, Connectors, Indicators DN9340EEQ Access and Displays Front Panel DN9340ESelected channel both channels if linked. When a Bypass, Channel Select, Soft Keys and Alphanumeric DisplaySoft keys Touch Strip, Store and Recall, Home Setup and Data Entry PC Port, Metering and Power Word clock Input Rear Panel DN9340EMains Inputs a and BSignal Flow DN9340E Signal Flow DN9340EHome page sub-menus Operation DN9340EOperation DN9340E HomeTouchstrip Operation on the Home Soft Key Functions Graphic EqualisationEQ Flat Automatic featuresGrouping Touchstrip operation with Graphic equalisationParametric Equalisation EQ remove Touchstrip operation with Parametric equalisationDynamic Equalisation Lo Threshold / LevelHi Threshold / Level Time constants Touchstrip operation with Dynamic equalisationFilters Create Filter functionFilter Type Left Encoder Centre Encoder Right Encoder Filter settings Touchstrip operation with FiltersFilter remove Metering Clear Down Sequence General Setup Menu DN9340ESetup Menu DN9340E To access the Set Up menu pagesTo select a slave remote communications channel Remote control via a PCTo switch remote communications off Comms channelTo remove the unit from the network Using a DN9340E for master controlTo select a master remote communications channel To select a slave communications channelFront Panel lock To set a Panel LockTo remove the Panel Lock To change the input source Analogue/Digital Input SelectTo select the output clock source Presets lockTo set a Presets lock Digital Output Clock SelectTo enter a name LCD contrast adjustmentDelay options Naming Pages 7Power-up Logo Ethernet Settings Pages 11Ethernet IP Address To check and edit the Subnet Mask Ethernet Subnet Mask SetupUsing the DN9340E Memories To store settingsTo recall settings Data model Remote ControlConnections AddressesOn a DN9344E Setting the master unit on-lineGetting started On a DN9340ETo set up the names OperationSystem naming To set up the assignment Copy channel functionSolo Tracking operation Helix DN9340E/DN9344E unit interconnections OverviewConnecting the Helix DN9340/DN9344E units in a daisy chain Ethernet connection wireless option Ethernet ConnectionEthernet connection standard Configuring the DN9344E for Network Communication Configuring the DN9340E for Network CommunicationConnection and Configuration Procedure Serial Connection OptionSerial connection details Power Switch Power on Power on indication Power indication Controls, Connectors, Indicators DN9344EAlphanumeric displays, SETUP, Metering and Power Press to step through the Set Up pagesIndicators Indicators, Up and Down Buttons, PC Port and Scribble StripsInterface Rear Panel DN9344EMains inlet socket 1B, 2A and 2BSignal Flow DN9344E Signal Flow DN9344EOperation DN9344E Operation DN9344ERemote Comms channels To select a remote communications channel To disable remote communications and relay operation To enable the Contact Closure Relay modeAnalogue/Digital Input Select Pages 3 PasswordTo set a password To change the settings for Inputs 1A and 1BDigital Output Clock Select Pages 5 To change the settings for OutputTo change the Subnet Mask Ethernet SettingsSubnet Mask To change the IP addressDynamic EQ Application NotesApplication Notes Application Notes What do we mean by all these Q types? Constant Q Proportional QSymmetrical Q What is AES/EBU? 17.1. DN9340E Technical Specification DN9340EPower Requirements 17.2. DN9344E Technical Specification DN9344ERelay Socket Pin D-type rear Power Pin IEC Service Information BatteryReplacement