Setup Menu: DN9340E

7.2.2Using a DN9340E for master control

Comms channels 1 to 32 are available, enabling a mater/slave network with one DN9340E unit acting as the master and up to 31 DN9340E and/or DN9344E slave units.

To select a master remote communications channel

1Press HOME (SETUP) for more than one second to access the Set Up menu; you will be taken immediately to the Comms page.

2Turn the left control knob clockwise to access the communications channels (SLAVE Mode).

3Turn the centre control knob clockwise to display communications channels in MASTER Mode.

4Turn the left control knob to select required master channel, for example, channel 23.

5Turn the right control knob to select the maximum number of inputs in the network, for example, 16. Inputs are always in pairs (two inputs per channel) and you can have a maximum of 64.

6Press HOME (SETUP). You have the option to upload the memory from the networked units (“Get All”) or download the memory from this unit to the other networked units (“Set All”). To access the “Set All” option, turn centre control knob anti-clockwise.

7Press HOME (SETUP). The unit will search for the other networked units and then display the following:

The front panel controls, except the HOME (SETUP) button, are locked out to facilitate remote operation. The display indicates that the unit is the master and is controlling the network.

To select a slave communications channel

To set the unit as a slave and select the communications channel, follow the procedure in “To select a slave remote communications channel” on page 27.

To remove the unit from the network

1Press and hold the HOME (SET UP) button to reopen the Comms page.

2Turn the centre control knob anti-clockwise to select Mode as “SLAVE”.

3Turn the left control knob anti-clockwise until Channel is set to “Off”.

4Press HOME (SETUP) to confirm your selection.

28

Image 38
Contents DN9340E/DN9344E Page Important Safety Instructions Page Declaration of Conformity Page Contents Setup Menu DN9340E Application Notes Page After Unpacking Safety WarningInstallation Considerations Page Quick Reference DN9340E Front PanelDN9344E Front Panel Introducing the DN9340E/DN9344E DN9340E & DN9344E Key FeaturesKey Features Host Software VersionsInterface to Midas consoles Remote control operationSpace efficiency Store and Recall ParametersFront Panel DN9340E Controls, Connectors, Indicators DN9340EEQ Access and Displays Soft keys displaySoft keys Selected channel both channels if linked. When aBypass, Channel Select, Soft Keys and Alphanumeric Display Touch Strip, Store and Recall, Home Setup and Data Entry PC Port, Metering and Power Inputs a and B Rear Panel DN9340EMains Word clock InputSignal Flow DN9340E Signal Flow DN9340EHome Operation DN9340EOperation DN9340E Home page sub-menusTouchstrip Operation on the Home Graphic Equalisation Soft Key FunctionsAutomatic features EQ FlatTouchstrip operation with Graphic equalisation GroupingParametric Equalisation Touchstrip operation with Parametric equalisation EQ removeHi Threshold / Level Dynamic EqualisationLo Threshold / Level Touchstrip operation with Dynamic equalisation Time constantsFilter Type Left Encoder Centre Encoder Right Encoder FiltersCreate Filter function Filter remove Filter settingsTouchstrip operation with Filters Metering Clear Down Sequence To access the Set Up menu pages Setup Menu DN9340ESetup Menu DN9340E GeneralComms channel Remote control via a PCTo switch remote communications off To select a slave remote communications channelTo select a slave communications channel Using a DN9340E for master controlTo select a master remote communications channel To remove the unit from the networkTo remove the Panel Lock Front Panel lockTo set a Panel Lock Analogue/Digital Input Select To change the input sourceDigital Output Clock Select Presets lockTo set a Presets lock To select the output clock sourceNaming Pages 7 LCD contrast adjustmentDelay options To enter a nameEthernet IP Address Power-up LogoEthernet Settings Pages 11 Ethernet Subnet Mask Setup To check and edit the Subnet MaskTo recall settings Using the DN9340E MemoriesTo store settings Addresses Remote ControlConnections Data modelOn a DN9340E Setting the master unit on-lineGetting started On a DN9344ESystem naming To set up the namesOperation Solo Tracking operation To set up the assignmentCopy channel function Overview Helix DN9340E/DN9344E unit interconnectionsConnecting the Helix DN9340/DN9344E units in a daisy chain Ethernet connection standard Ethernet connection wireless optionEthernet Connection Configuring the DN9340E for Network Communication Configuring the DN9344E for Network CommunicationSerial connection details Connection and Configuration ProcedureSerial Connection Option Press to step through the Set Up pages Controls, Connectors, Indicators DN9344EAlphanumeric displays, SETUP, Metering and Power Power Switch Power on Power on indication Power indicationIndicators, Up and Down Buttons, PC Port and Scribble Strips Indicators1B, 2A and 2B Rear Panel DN9344EMains inlet socket InterfaceSignal Flow DN9344E Signal Flow DN9344ERemote Comms channels Operation DN9344EOperation DN9344E To select a remote communications channel To enable the Contact Closure Relay mode To disable remote communications and relay operationTo change the settings for Inputs 1A and 1B PasswordTo set a password Analogue/Digital Input Select Pages 3To change the settings for Output Digital Output Clock Select Pages 5To change the IP address Ethernet SettingsSubnet Mask To change the Subnet MaskApplication Notes Dynamic EQApplication Notes Application Notes What do we mean by all these Q types? Proportional Q Constant QSymmetrical Q What is AES/EBU? Technical Specification DN9340E 17.1. DN9340EPower Requirements Technical Specification DN9344E 17.2. DN9344ERelay Socket Pin D-type rear Power Pin IEC Replacement Service InformationBattery