Klark Teknik DN9344E, DN9340E specifications Application Notes

Page 67

Application Notes

Without changing modes or making any other selections, we can make the unit operate ‘the other way up’ just by selecting suitable values for the two thresholds and levels see Figure 3.

In this case, [low threshold] is -20dBu, [low level] is 0dB, [high threshold] is -5dBu, and [high level] is +12dB, so that instead of cutting this frequency range as the level increases, we are now boosting it. Again, we have precise control over the maximum amount of boost that will be applied, and the level at which this will occur. Note the shape of the curve for -5dBu, which has ‘expected values’ outside the filter range and at the centre frequency, but intermediate values that show the EQ ramping in and out either side of the centre frequency.

Needless to say, there is no requirement for one of the levels to be 0dB. Figure 4 shows the transition from a +12dB boost at low level to a -12dB cut at high levels. Again, the intermediate curves show the effect of the sweep signal moving in and out of the ‘area of interest’ of the level detector as the curve is formed.

57

Image 67
Contents DN9340E/DN9344E Page Important Safety Instructions Page Declaration of Conformity Page Contents Setup Menu DN9340E Application Notes Page Installation Considerations Safety WarningAfter Unpacking Page DN9340E Front Panel Quick ReferenceDN9344E Front Panel Host Software Versions DN9340E & DN9344E Key FeaturesKey Features Introducing the DN9340E/DN9344EStore and Recall Parameters Remote control operationSpace efficiency Interface to Midas consolesSoft keys display Controls, Connectors, Indicators DN9340EEQ Access and Displays Front Panel DN9340EBypass, Channel Select, Soft Keys and Alphanumeric Display Selected channel both channels if linked. When aSoft keys Touch Strip, Store and Recall, Home Setup and Data Entry PC Port, Metering and Power Word clock Input Rear Panel DN9340EMains Inputs a and BSignal Flow DN9340E Signal Flow DN9340EHome page sub-menus Operation DN9340EOperation DN9340E HomeTouchstrip Operation on the Home Soft Key Functions Graphic EqualisationEQ Flat Automatic featuresGrouping Touchstrip operation with Graphic equalisationParametric Equalisation EQ remove Touchstrip operation with Parametric equalisationLo Threshold / Level Dynamic EqualisationHi Threshold / Level Time constants Touchstrip operation with Dynamic equalisationCreate Filter function FiltersFilter Type Left Encoder Centre Encoder Right Encoder Touchstrip operation with Filters Filter settingsFilter remove Metering Clear Down Sequence General Setup Menu DN9340ESetup Menu DN9340E To access the Set Up menu pagesTo select a slave remote communications channel Remote control via a PCTo switch remote communications off Comms channelTo remove the unit from the network Using a DN9340E for master controlTo select a master remote communications channel To select a slave communications channelTo set a Panel Lock Front Panel lockTo remove the Panel Lock To change the input source Analogue/Digital Input SelectTo select the output clock source Presets lockTo set a Presets lock Digital Output Clock SelectTo enter a name LCD contrast adjustmentDelay options Naming Pages 7Ethernet Settings Pages 11 Power-up LogoEthernet IP Address To check and edit the Subnet Mask Ethernet Subnet Mask SetupTo store settings Using the DN9340E MemoriesTo recall settings Data model Remote ControlConnections AddressesOn a DN9344E Setting the master unit on-lineGetting started On a DN9340EOperation To set up the namesSystem naming Copy channel function To set up the assignmentSolo Tracking operation Helix DN9340E/DN9344E unit interconnections OverviewConnecting the Helix DN9340/DN9344E units in a daisy chain Ethernet Connection Ethernet connection wireless optionEthernet connection standard Configuring the DN9344E for Network Communication Configuring the DN9340E for Network CommunicationSerial Connection Option Connection and Configuration ProcedureSerial connection details Power Switch Power on Power on indication Power indication Controls, Connectors, Indicators DN9344EAlphanumeric displays, SETUP, Metering and Power Press to step through the Set Up pagesIndicators Indicators, Up and Down Buttons, PC Port and Scribble StripsInterface Rear Panel DN9344EMains inlet socket 1B, 2A and 2BSignal Flow DN9344E Signal Flow DN9344EOperation DN9344E Operation DN9344ERemote Comms channels To select a remote communications channel To disable remote communications and relay operation To enable the Contact Closure Relay modeAnalogue/Digital Input Select Pages 3 PasswordTo set a password To change the settings for Inputs 1A and 1BDigital Output Clock Select Pages 5 To change the settings for OutputTo change the Subnet Mask Ethernet SettingsSubnet Mask To change the IP addressDynamic EQ Application NotesApplication Notes Application Notes What do we mean by all these Q types? Constant Q Proportional QSymmetrical Q What is AES/EBU? 17.1. DN9340E Technical Specification DN9340EPower Requirements 17.2. DN9344E Technical Specification DN9344ERelay Socket Pin D-type rear Power Pin IEC Battery Service InformationReplacement
Related manuals
Manual 65 pages 57.17 Kb