Klark Teknik DN9344E, DN9340E specifications Graphic Equalisation, Soft Key Functions

Page 25

Operation: DN9340E

6.2. Graphic Equalisation

Select graphic equalisation by pressing the GRAPHIC button.

The default display for the graphic EQ is 31 faders indicating the gain of the 31 bands of the 1/3 octave equaliser. The left encoder can be used to select a fader and then the right encoder can be used to set the gain for that fader. Alternatively, the fader can be selected using the upper or lower section of the touch strip. If the touch strip is pressed for longer than half a second then the selected fader will move up (upper strip) or down (lower strip) until the touchstrip is released.

6.2.1Soft Key Functions

selects the next fader (to the right) or clears the current group selection (selector returns to the 20Hz fader).

steps through the following pages on the alphanumeric display. After the last page, the next press returns to the first page, and so on.

pressing this allows an individual fader or a selected block of faders to be switched in and out of circuit. Faders are shown as when switched out or if selected at the line.

Default page shows frequency and level for the currently-selected fader

EQ mode page

EQ type - allows the selection of different EQ characteristics. Proportional, Constant and Symmetrical-Q types are available, together with emulations of the classic Klark Teknik DN360 and DN27. See the application notes later in this manual for more details on selecting EQ types and Q. If in doubt, select either DN27 or DN360 emulation for sensible curves with minimum fuss …

Q - only available with Proportional, Constant and Symmetrical-Q types. This should be adjusted with care, as it is possible to produce both large amounts of overlap between bands and also narrow filters with large inter-band ripple. The default position for normal 1/3 octave operation is clearly indicated on the display.

Graph Mode - this toggles the large graphic display between the fader display and a frequency response curve.

15

Image 25
Contents DN9340E/DN9344E Page Important Safety Instructions Page Declaration of Conformity Page Contents Setup Menu DN9340E Application Notes Page Installation Considerations Safety WarningAfter Unpacking Page DN9340E Front Panel Quick ReferenceDN9344E Front Panel Key Features DN9340E & DN9344E Key FeaturesIntroducing the DN9340E/DN9344E Host Software VersionsSpace efficiency Remote control operationInterface to Midas consoles Store and Recall ParametersEQ Access and Displays Controls, Connectors, Indicators DN9340EFront Panel DN9340E Soft keys displayBypass, Channel Select, Soft Keys and Alphanumeric Display Selected channel both channels if linked. When aSoft keys Touch Strip, Store and Recall, Home Setup and Data Entry PC Port, Metering and Power Mains Rear Panel DN9340EInputs a and B Word clock InputSignal Flow DN9340E Signal Flow DN9340EOperation DN9340E Operation DN9340EHome Home page sub-menusTouchstrip Operation on the Home Soft Key Functions Graphic EqualisationEQ Flat Automatic featuresGrouping Touchstrip operation with Graphic equalisationParametric Equalisation EQ remove Touchstrip operation with Parametric equalisationLo Threshold / Level Dynamic EqualisationHi Threshold / Level Time constants Touchstrip operation with Dynamic equalisationCreate Filter function FiltersFilter Type Left Encoder Centre Encoder Right Encoder Touchstrip operation with Filters Filter settingsFilter remove Metering Clear Down Sequence Setup Menu DN9340E Setup Menu DN9340ETo access the Set Up menu pages GeneralTo switch remote communications off Remote control via a PCComms channel To select a slave remote communications channelTo select a master remote communications channel Using a DN9340E for master controlTo select a slave communications channel To remove the unit from the networkTo set a Panel Lock Front Panel lockTo remove the Panel Lock To change the input source Analogue/Digital Input SelectTo set a Presets lock Presets lockDigital Output Clock Select To select the output clock sourceDelay options LCD contrast adjustmentNaming Pages 7 To enter a nameEthernet Settings Pages 11 Power-up LogoEthernet IP Address To check and edit the Subnet Mask Ethernet Subnet Mask SetupTo store settings Using the DN9340E MemoriesTo recall settings Connections Remote ControlAddresses Data modelGetting started Setting the master unit on-lineOn a DN9340E On a DN9344EOperation To set up the namesSystem naming Copy channel function To set up the assignmentSolo Tracking operation Helix DN9340E/DN9344E unit interconnections OverviewConnecting the Helix DN9340/DN9344E units in a daisy chain Ethernet Connection Ethernet connection wireless optionEthernet connection standard Configuring the DN9344E for Network Communication Configuring the DN9340E for Network CommunicationSerial Connection Option Connection and Configuration ProcedureSerial connection details Alphanumeric displays, SETUP, Metering and Power Controls, Connectors, Indicators DN9344EPress to step through the Set Up pages Power Switch Power on Power on indication Power indicationIndicators Indicators, Up and Down Buttons, PC Port and Scribble StripsMains inlet socket Rear Panel DN9344E1B, 2A and 2B InterfaceSignal Flow DN9344E Signal Flow DN9344EOperation DN9344E Operation DN9344ERemote Comms channels To select a remote communications channel To disable remote communications and relay operation To enable the Contact Closure Relay modeTo set a password PasswordTo change the settings for Inputs 1A and 1B Analogue/Digital Input Select Pages 3Digital Output Clock Select Pages 5 To change the settings for OutputSubnet Mask Ethernet SettingsTo change the IP address To change the Subnet MaskDynamic EQ Application NotesApplication Notes Application Notes What do we mean by all these Q types? Constant Q Proportional QSymmetrical Q What is AES/EBU? 17.1. DN9340E Technical Specification DN9340EPower Requirements 17.2. DN9344E Technical Specification DN9344ERelay Socket Pin D-type rear Power Pin IEC Battery Service InformationReplacement
Related manuals
Manual 65 pages 57.17 Kb