Klark Teknik DN9344E, DN9340E Touchstrip operation with Graphic equalisation, Grouping

Page 27

Operation: DN9340E

6.2.2Touchstrip operation with Graphic equalisation

On the Graphic EQ page, the touchstrip provides an alternative to using the encoder knobs for selecting and operating the faders on the display. If you are not currently using the Freq/Level menu, the unit automatically switches to it when you press the touchstrip. Touch either the upper or lower part of the touchstrip below the fader frequency that you want to select. The fader will highlight to indicate the selection. Tapping repeatedly at the same position will result in the fader level moving up (upper strip) or down (lower strip) in 0.5dB increments. Pressing the strip continuously in the same place will result in the fader ramping up or down over its full range. As an aid to resetting faders to exactly 0dB, this ramping motion will stop as the fader passes over the 0dB position. Release the touchstrip and then press again to continue moving past this point.

6.2.3Grouping

Groups of faders can be created and moved together. This is achieved by pressing below one fader on the upper strip, and below a different fader on the lower strip. A group will be created that includes all faders between those two selected ones. This can now be moved up and down using the encoder knob or by using the touchstrip in the area below the group. Pressing the touchstrip outside the range of the group or moving the “frequency” encoder knob will disband the group.

17

Image 27
Contents DN9340E/DN9344E Page Important Safety Instructions Page Declaration of Conformity Page Contents Setup Menu DN9340E Application Notes Page Safety Warning Installation ConsiderationsAfter Unpacking Page DN9340E Front Panel Quick ReferenceDN9344E Front Panel Host Software Versions DN9340E & DN9344E Key FeaturesKey Features Introducing the DN9340E/DN9344EStore and Recall Parameters Remote control operationSpace efficiency Interface to Midas consolesSoft keys display Controls, Connectors, Indicators DN9340EEQ Access and Displays Front Panel DN9340ESelected channel both channels if linked. When a Bypass, Channel Select, Soft Keys and Alphanumeric DisplaySoft keys Touch Strip, Store and Recall, Home Setup and Data Entry PC Port, Metering and Power Word clock Input Rear Panel DN9340EMains Inputs a and BSignal Flow DN9340E Signal Flow DN9340EHome page sub-menus Operation DN9340EOperation DN9340E HomeTouchstrip Operation on the Home Soft Key Functions Graphic EqualisationEQ Flat Automatic featuresGrouping Touchstrip operation with Graphic equalisationParametric Equalisation EQ remove Touchstrip operation with Parametric equalisationDynamic Equalisation Lo Threshold / LevelHi Threshold / Level Time constants Touchstrip operation with Dynamic equalisationFilters Create Filter functionFilter Type Left Encoder Centre Encoder Right Encoder Filter settings Touchstrip operation with FiltersFilter remove Metering Clear Down Sequence General Setup Menu DN9340ESetup Menu DN9340E To access the Set Up menu pagesTo select a slave remote communications channel Remote control via a PCTo switch remote communications off Comms channelTo remove the unit from the network Using a DN9340E for master controlTo select a master remote communications channel To select a slave communications channelFront Panel lock To set a Panel LockTo remove the Panel Lock To change the input source Analogue/Digital Input SelectTo select the output clock source Presets lockTo set a Presets lock Digital Output Clock SelectTo enter a name LCD contrast adjustmentDelay options Naming Pages 7Power-up Logo Ethernet Settings Pages 11Ethernet IP Address To check and edit the Subnet Mask Ethernet Subnet Mask SetupUsing the DN9340E Memories To store settingsTo recall settings Data model Remote ControlConnections AddressesOn a DN9344E Setting the master unit on-lineGetting started On a DN9340ETo set up the names OperationSystem naming To set up the assignment Copy channel functionSolo Tracking operation Helix DN9340E/DN9344E unit interconnections OverviewConnecting the Helix DN9340/DN9344E units in a daisy chain Ethernet connection wireless option Ethernet ConnectionEthernet connection standard Configuring the DN9344E for Network Communication Configuring the DN9340E for Network CommunicationConnection and Configuration Procedure Serial Connection OptionSerial connection details Power Switch Power on Power on indication Power indication Controls, Connectors, Indicators DN9344EAlphanumeric displays, SETUP, Metering and Power Press to step through the Set Up pagesIndicators Indicators, Up and Down Buttons, PC Port and Scribble StripsInterface Rear Panel DN9344EMains inlet socket 1B, 2A and 2BSignal Flow DN9344E Signal Flow DN9344EOperation DN9344E Operation DN9344ERemote Comms channels To select a remote communications channel To disable remote communications and relay operation To enable the Contact Closure Relay modeAnalogue/Digital Input Select Pages 3 PasswordTo set a password To change the settings for Inputs 1A and 1BDigital Output Clock Select Pages 5 To change the settings for OutputTo change the Subnet Mask Ethernet SettingsSubnet Mask To change the IP addressDynamic EQ Application NotesApplication Notes Application Notes What do we mean by all these Q types? Constant Q Proportional QSymmetrical Q What is AES/EBU? 17.1. DN9340E Technical Specification DN9340EPower Requirements 17.2. DN9344E Technical Specification DN9344ERelay Socket Pin D-type rear Power Pin IEC Service Information BatteryReplacement
Related manuals
Manual 65 pages 57.17 Kb