3Translating the IPSIs Administering the IPSIs
Setting alarm activation level
1Type change system-parameters maintenance and press Enter.
change |
| Page 1 of 3 |
OPERATIONS SUPPORT PARAMETERS |
|
|
CPE Alarm Activation Level: none |
|
|
SCHEDULED MAINTENANCE |
|
|
Start Time: | 22 | : 00 |
Stop Time: | 06 | : 00 |
Save Translation: | daily | |
Update LSPs When Saving Translations: | y |
|
Command | 2 |
|
Control Channel Interchange: | no |
|
System Clocks/IPSI Interchange: | no |
|
|
|
|
2In the CPE Alarm Activation Level field, select none (default), warning, minor, or major, depending on the level the customer wants and press Enter to effect the changes.
3Repeat for each IPSI.
Installing the translation file
1Type save translations and press Enter to save the translations to the hard drive.
48 | Installing and Configuring the Avaya S8700 or S8710 Media Server |
| June 2004 |