Schneider Electric 312 Configuration with SyCON additional Software, Configuration of the slave

Page 25

Integration of the ATV312 in a PROFIBUS DP network controlled by a Modicon TSX P57 354M

Configuration with SyCON additional Software

To configure an ATV312 as a slave device on the PBY 100 master, you must configure the PROFIBUS DP with the SyCON configuration tool. For the first time configuration, you must add the GSD file of the ATV312 (available on Schneider-electric.com) to the configuration tool:

• File Menu > Copy GSD file

Once done, you can add a slave device by selecting:

Schneider Electric as Vendor

Altivar 312 as slave Device

Configuration of the slave

Define the address, in accordance with the DIP switches of the VW3 A312 07, and define a name to the Device. There are no additional configurations given that the Altivar 312 PROFIBUS DP module provides an unique mapping.

S1A10386 10/2009

25

Image 25
Contents Altivar Page Contents Please Note Important InformationHazard of Electric SHOCK, EXPLOSION, or ARC Flash Before you beginDocumentation structure Presentation IntroductionDrive terminal displays FormatsInstalling the card in the drive Hardware setupReceipt Hardware setup Terminal Function Electrical characteristics Characteristics and functions of the terminalsTherefore the direction of operation Connection to the Modbus base port Number Terminal Electrical characteristicsConnection to the Profibus DP network Example of connection Connection accessoriesWire sizes Wiring diagram for ATV 312 equipped with VW3 A312Recommendations Address Switches 5-4-3-2-1 ConfigurationCoding the drive address At first power on with a Profibus DP option card Drive default valuesPower on after removing the Profibus DP option card Control of the drive when LAC = L3 Control of the drive when LAC = L1 or L2Control of an ATV 312 from a Profibus DP option card Parameter Value CommentControl via Profibus DP in native profile CiA402 Diagnostic LEDs DiagnosticsDX Green LED Status ST Red LED StatusCode Name Probable cause Remedy Communication fault managementProfibus DP protocol Profibus DP mappingInput PZDs Output PZDsPKW request Output PKWs PKW aperiodic serviceInput PKWs Examples of PKW aperiodic exchanges Project configuration Configuration of the communicationPL7 output word Altivar PL7 input word AltivarConfiguration of the slave Configuration with SyCON additional SoftwareSave the projet PLC IO image / Altivar 312 DP slave mappingPZD area Altivar TSX P57 354M TSX P57 354 M IO memory PKW areaExample of Control of the Drive Ready for switch onAnimated operator screen example Configuration of the device GSD installationS1A10386 10/2009 PZD area PLC IO image / Altivar 312 DP slave mappingPKW area Altivar S7-315 PEW S7 315 PAW Parameter IO memoryIEC 61800-7 status chart Supervision and control in Line modeSwitch on disabled Configuration Not ready to switch on InitializationReady to switch on and Switched on Drive initialized Operation enabled OperationalCMD control word W8501 MSK = ETA ETA status word W3201ATV312PROFIBUSDPS1A1038601 S1A10386 10/2009