Schneider Electric 312 manual Before you begin, Hazard of Electric SHOCK, EXPLOSION, or ARC Flash

Page 5

Before you begin

Read and understand these instructions before performing any procedure with this drive.

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

Read and understand this manual before installing or operating the Altivar 312 drive. Installation, adjustment, repair, and maintenance must be performed by qualified personnel.

The user is responsible for compliance with all international and national electrical code requirements with respect to grounding of all equipment.

Many parts of this drive, including the printed circuit boards, operate at the line voltage. DO NOT TOUCH. Use only electrically insulated tools.

DO NOT touch unshielded components or terminal strip screw connections with voltage present.

DO NOT short across terminals PA/+ and PC/– or across the DC bus capacitors.

Before servicing the drive:

-Disconnect all power, including external control power that may be present.

-Place a “DO NOT TURN ON” label on all power disconnects.

-Lock all power disconnects in the open position.

-WAIT 15 MINUTES to allow the DC bus capacitors to discharge.

-Measure the voltage of the DC bus between the PA/+ and PC/– terminals to ensure that the voltage is less than 42 Vdc.

-If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair or operate the drive.

Install and close all covers before applying power or starting and stopping the drive.

Failure to follow these instructions will result in death or serious injury.

DANGER

UNINTENDED EQUIPMENT OPERATION

Read and understand this manual before installing or operating the Altivar 312 drive.

Any changes made to the parameter settings must be performed by qualified personnel.

Failure to follow these instructions will result in death or serious injury.

WARNING

DAMAGED DRIVE EQUIPMENT

Do not operate or install any drive or drive accessory that appears damaged.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

WARNING

LOSS OF CONTROL

The designer of any control scheme must

-consider the potential failure modes of control paths and, for certain critical control functions,

-provide a means to achieve a safe state during and after a path failure.

Examples of critical control functions are emergency stop and overtravel stop.

Separate or redundant control paths must be provided for critical control functions.

System control paths may include communication links. Consideration must be given to the implications of unanticipated transmission delays or failures of the link.a

Failure to follow these instructions can result in death, serious injury, or equipment damage.

a.For additional information, refer to NEMA ICS 1.1 (latest edition), “Safety Guidelines for the Application, Installation, and Maintenance of Solid State Control” and to NEMA ICS 7.1 (latest edition), “Safety Standards for Construction and Guide for Selection, Installation and Operation of Adjustable-Speed Drive Systems.”

S1A10386 10/2009

5

Image 5
Contents Altivar Page Contents Please Note Important InformationHazard of Electric SHOCK, EXPLOSION, or ARC Flash Before you beginDocumentation structure Presentation IntroductionDrive terminal displays FormatsReceipt Hardware setupInstalling the card in the drive Hardware setup Therefore the direction of operation Characteristics and functions of the terminalsTerminal Function Electrical characteristics Connection to the Profibus DP network Number Terminal Electrical characteristicsConnection to the Modbus base port Example of connection Connection accessoriesRecommendations Wiring diagram for ATV 312 equipped with VW3 A312Wire sizes Coding the drive address ConfigurationAddress Switches 5-4-3-2-1 Power on after removing the Profibus DP option card Drive default valuesAt first power on with a Profibus DP option card Control of the drive when LAC = L3 Control of the drive when LAC = L1 or L2Control of an ATV 312 from a Profibus DP option card Parameter Value CommentControl via Profibus DP in native profile CiA402 Diagnostic LEDs DiagnosticsDX Green LED Status ST Red LED StatusCode Name Probable cause Remedy Communication fault managementProfibus DP protocol Profibus DP mappingPKW request Output PZDsInput PZDs Input PKWs PKW aperiodic serviceOutput PKWs Examples of PKW aperiodic exchanges Project configuration Configuration of the communicationPL7 output word Altivar PL7 input word AltivarConfiguration of the slave Configuration with SyCON additional SoftwarePZD area PLC IO image / Altivar 312 DP slave mappingSave the projet Altivar TSX P57 354M TSX P57 354 M IO memory PKW areaExample of Control of the Drive Ready for switch onAnimated operator screen example Configuration of the device GSD installationS1A10386 10/2009 PZD area PLC IO image / Altivar 312 DP slave mappingPKW area Altivar S7-315 PEW S7 315 PAW Parameter IO memoryIEC 61800-7 status chart Supervision and control in Line modeSwitch on disabled Configuration Not ready to switch on InitializationReady to switch on and Switched on Drive initialized Operation enabled OperationalCMD control word W8501 MSK = ETA ETA status word W3201ATV312PROFIBUSDPS1A1038601 S1A10386 10/2009