ZONES
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER REBOOT SYSTEM
EXIT
DOME SETTINGS
<CAMERA> <MOTION>
<AUTO TRACKING> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>
BACK
EXIT
ZONES
ZONE NUMBER
* * * ZONE NOT DEFINED * * *
<EDIT ZONE LABEL>
<EDIT ZONE>
ZONE ENABLED ZONE BLANKING
<CLEAR ZONE>
BACK
EXIT
A zone is a pan area, defined by a left and right limit, on the
To configure a zone:
1.Use the joystick to position the cursor beside ZONE NUMBER. Press Iris Open, and the cursor moves to the right.
2.Move the joystick up or down to view selections. Press Iris Open to enter selection.
3.Use the joystick to position the cursor beside EDIT ZONE.
4.Press Iris Open. The Zone configuration window appears.
5.Follow the directions displayed on the monitor. After the left and right limit stops are set, the Zones menu reappears with the ZONE ENABLED option set to YES.
To edit a zone label:
1.Use the joystick to position the cursor beside EDIT ZONE LABEL.
2.Press Iris Open. The following information appears:
LABEL FOR ZONE
ZONE NUMBER ------
1234567890 | OK |
ABCDEFGHIJ | CANCEL |
KLMNOPQRST |
|
BACKSPACE | |
abcdefghij | SPACE |
klmnopqrst |
|
uvwxyz*;: |
|
3.Use the joystick to position the cursor beside a character. Press Iris Open to enter selection. To clear a character, position the cursor beside BACKSPACE, and then press Iris Open.
4.When the label is completed, move the cursor to OK. Press Iris Open to return to the Zones menu.
To disable a zone (a zone is enabled automatically when it is configured) or to blank a zone:
1.Move the cursor beside ZONE ENABLED or ZONE BLANKING.
2.Press Iris Open. The cursor moves to the right.
3.Move the joystick up or down to view selections. Press Iris Open to enter selection.
To clear a zone:
1.Use the joystick to position the cursor beside CLEAR ZONE.
2.Press Iris Open. Follow the instructions on the screen.
*This setting applies to Pressurized Spectra IV dome systems only.
40 |