Pelco C3463M-B manual Repeat, ACK Action, System Condition Alert Message

Page 48

ALERT

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DOME SETTINGS

 

 

 

 

ALERT

<CAMERA>

 

 

 

 

REPEAT

<MOTION>

 

 

 

 

ACK ACTION

<AUTO TRACKING>

 

 

 

 

ACTIVATE AUX

<POWER UP>

 

 

 

 

<CURRENT READING>

<LINE SYNC>

 

 

 

 

RESET ALERT

<PRESETS>

 

 

 

 

BACK

<PATTERNS>

 

 

 

 

<ZONES>

 

 

 

 

EXIT

<WINDOW BLANKING>

 

 

 

 

 

<ALARMS>

 

 

 

 

 

<AUX>

 

 

 

 

 

<TITLE TEXT>

 

 

 

 

 

<ALERT>

 

 

 

 

 

<CLEAR>

 

 

 

 

 

<PASSWORD>

 

 

 

 

 

<CLOCK>

 

 

 

 

 

<EVENT>

 

 

 

 

 

BACK

 

 

 

 

 

EXIT

 

 

 

 

 

NOTE: The Alert option applies to Pressurized Spectra IV dome systems only. Spectra IV systems that are not pressurized will not display this menu item.

Sensors strategically placed inside the pressurized dome system continually monitor pressure, temperature, and dew point. If internal conditions reach unacceptable levels, an alert message appears on the screen describing the alert condition. For example, if pressure drops below 1 psig, LOW PRESSURE is displayed.

The following system conditions will trigger an alert message:

System Condition

Alert Message

Temperature is above 140°F (60°C)

HIGH TEMPERATURE

Temperature is below –40°F (–40°C)

LOW TEMPERATURE

Pressure is above 13 PSIG

HIGH PRESSURE

Pressure is below 1 PSIG

LOW PRESSURE

The difference between the temperature and

DEW POINT (HIGH HUMIDITY)

the dew point is less than or equal to 3°C.

 

The alert message will be repeatedly displayed until the system controller acknowledges the alert condition by selecting ACK ALERT in the main menu. Once acknowledged, the alert message changes to the configured acknowledge action (ACK ACTION). If the alert condition remains active after a period of time, the alert message reappears on the monitor, restarting the alert message cycle. This cycle will continue to repeat until the alert condition is resolved.

REPEAT

This setting programs how often an alert message is repeatedly displayed until the system controller acknowledges the alert condition. The following are the settings:

CONSTANT: The alert message is continuously displayed until acknowledged.

15 MIN: The alert message is displayed every 15 minutes for a 15-second duration until acknowledged.

30 MIN: The alert message is displayed every 30 minutes for a 15-second duration until acknowledged.

60 MIN: The alert message is displayed every 60 minutes for a 15-second duration until acknowledged.

OFF: The alert message is disabled and will not be displayed.

ACK ACTION

Set ACK ACTION to configure the frequency at which an alert message is displayed after the alert condition has been acknowledged. The following settings are available:

ALWAYS ON: The alert message is displayed until alert conditions are cleared.

OFF 8 HRS: The alert message is turned off for 8 hours. Message returns after 8 hours if the alert condition persists.

OFF 24 HRS: The alert message is turned off for 24 hours. Message returns after 24 hours if the alert condition persists.

OFF 48 HRS: The alert message is turned off for 48 hours. Message returns after 48 hours if the alert condition persists.

48

C3463M-B (2/11)

Image 48
Contents Spectra IV SL and Spectra IV SE Series Page Contents Field Align Page Description Installation Switch SettingsSW2 Switches 4 and 5 Serial Port Settings SW2 Switches 6 to 8 Baud SettingsDome Drive AddressQuick Configuration Guide OperationQuick Operation Guide Preset 95 Accessing Main Menu Extended Coaxitron or RS-485 ModeEndura Workstation Digital Sentry System SoftwareDigital Sentry DS Controlpoint 23X LowLight Day/Night Menu Tree Dome Settings Line Sync PresetsAlarms Password Edit the PasswordAlert Current Reading Clear Password 27X LowLight Day/Night Menu TreeLabel Position Patterns ZonesPower UP Line Sync Presets Motion Detection Event Edit Event35X LowLight Day/Night Menu Tree Azimuth Elevation Zoom Custom Camera Settings Reset Camera Cycle Camera Power Reboot System Exit LanguageSpectra Language DIP Switch Information System InformationDisplay Setup Exit Display Setup Preset LabelRestore Factory Defaults Back Exit Title Text Save and Exit Cancel Help Label PositionsEvent Alert MessageDome Settings CameraType of Lighting Auto FocusZoom Limit Zoom SpeedLOW Light Limit PT Focus LockIR CUT Filter Auto IR LevelLow Light Focus Advanced Camera Settings Shutter SpeedAGC Limit Auto IrisAuto Sharpness Auto White BalanceBacklight Compensation Electronic Image StabilizationOFF Low lux noise reduction is disabled LOW LUX Noise ReductionVideo Level Field AlignMotion Settings LOW Light SharpnessMinimum Focus Distance Auto FlipPreset Freeze Frame Park TimeScan Speed Limit StopsPower UP Start Time Line Sync Zoom Presets Lost Action Auto TrackingAzimuth Zero Auto TrackingDisplay Setup SensitivityStart Time ZoomPower UP Power UP ActionBack Exit Power UP Power UP Action Presets Table C. Stored Presets by Back Box ModelBack Exit Line Sync Line Sync Phase Back Exit Presets Preset NumberPreset 83 to 87 Reserved Preset 92 to 93 Scan limit stops Preset 94 ReservedPreset 95 Select main configuration menu Preset 96 Stop a scanLabel for Preset Preset Number Abcdefghij Cancel Klmnopqrst UvwxyzSpace Enable Motion Detection Motion DetectionEdit Detection Areas Activate Aux Command Edit ScheduleAux Time Patterns Back Exit PatternsBack Exit Zones Back Exit Zones Zone NumberEdit Zone Label Clear Zone Back ExitEnable Window Reverse Clear Window Back Exit Window BlankingTo set a window blanking area Disabled ReverseClear Window Blank ALL ABOVE/BLANK ALL below Blank All Above Blank All BelowBlanked Area Alarms C3463M-B 2/11 Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 Mode AUXDwell Time Secs Edit Schedule Back Exit Title Text Back Exit Title TextEdit Title Text Alert RepeatACK Action System Condition Alert MessageReset Alert None default Not activatedActivate AUX Current ReadingPassword Back Exit PasswordEnable Password Edit Password Back Abcdefghij Cancel Klmnopqrst Exit UvwxyzClock Follow the instructions in for Fixed DATE, adding Week Event Event TypeBack Exit Event Event Type Event Label HolidayEvent Label Edit Event LabelEdit Event Clear Event List EventHoliday Edit HolidayClear Holiday List HolidaysEdit Holiday Occurrence Month January DAY Back ExitExample Preset Weekend 1100 AM Sat-Sun Scheduled EventsUse this page to record scheduled events Reset, Cycle Power, Reboot Reset CameraCycle Camera Power Reboot SystemSoftware/Language File Upload Maintenance Specifications Signal Format23X Models Zoom Speed 4.2/5.8 seconds Horizontal Angle of View27X Models DD42735X Models DD4CBW35Table F. Switch Settings for SW1 Pelco P-Type Control AppendixTable G. Switch Settings for SW1 Pelco D-Type Control 1 Spectra Switch Setting AddressTable G. Switch Settings for SW1 Pelco D-Type Control 2 Table G. Switch Settings for SW1 Pelco D-Type Control 3 Table G. Switch Settings for SW1 Pelco D-Type Control 4 Table G. Switch Settings for SW1 Pelco D-Type Control 5 Table G. Switch Settings for SW1 Pelco D-Type Control 6 Product Warranty and Return Information