Pelco C3463M-B manual Table G. Switch Settings for SW1 Pelco D-Type Control 1

Page 65

Table G. Switch Settings for SW1 Pelco D-Type Control (1 of 6)

SPECTRA

 

 

 

SWITCH SETTING

 

 

 

 

 

 

 

 

 

 

 

ADDRESS

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

SW1-6

SW1-7

SW1-8

 

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

12

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

13

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

14

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

15

ON

ON

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

17

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

18

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

19

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

20

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

21

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

22

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

23

ON

ON

ON

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

24

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

25

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

26

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

27

ON

ON

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

28

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

29

ON

OFF

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

30

OFF

ON

ON

ON

ON

OFF

OFF

OFF

31

ON

ON

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

32

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

33

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

34

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

35

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

36

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

37

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

38

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

39

ON

ON

ON

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

40

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

41

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

42

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

43

ON

ON

OFF

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

44

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

45

ON

OFF

ON

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

46

OFF

ON

ON

ON

OFF

ON

OFF

OFF

47

ON

ON

ON

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

48

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

49

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

C3463M-B (2/11)

65

Image 65
Contents Spectra IV SL and Spectra IV SE Series Page Contents Field Align Page Description Switch Settings InstallationSW2 Switches 6 to 8 Baud Settings SW2 Switches 4 and 5 Serial Port SettingsAddress Dome DriveQuick Operation Guide Quick Configuration GuideOperation Extended Coaxitron or RS-485 Mode Preset 95 Accessing Main MenuDigital Sentry DS Controlpoint Endura WorkstationDigital Sentry System Software 23X LowLight Day/Night Menu Tree Line Sync Presets Dome SettingsAlarms Password Edit the Password27X LowLight Day/Night Menu Tree Alert Current Reading Clear PasswordLabel Position Patterns ZonesEvent Edit Event Power UP Line Sync Presets Motion Detection35X LowLight Day/Night Menu Tree Azimuth Elevation Zoom Custom Camera Settings Spectra Language Reset Camera Cycle Camera Power Reboot System ExitLanguage System Information DIP Switch InformationRestore Factory Defaults Back Exit Display SetupExit Display Setup Preset Label Label Positions Title Text Save and Exit Cancel HelpEvent Alert MessageCamera Dome SettingsType of Lighting Auto FocusZoom Speed Zoom LimitLOW Light Limit PT Focus LockLow Light Focus IR CUT FilterAuto IR Level Shutter Speed Advanced Camera SettingsAGC Limit Auto IrisAuto White Balance Auto SharpnessBacklight Compensation Electronic Image StabilizationLOW LUX Noise Reduction OFF Low lux noise reduction is disabledVideo Level Field AlignLOW Light Sharpness Motion SettingsMinimum Focus Distance Auto FlipPark Time Preset Freeze FrameScan Speed Limit StopsAuto Tracking Power UP Start Time Line Sync Zoom Presets Lost ActionAzimuth Zero Auto TrackingSensitivity Display SetupStart Time ZoomBack Exit Power UP Power UP Action Power UPPower UP Action Table C. Stored Presets by Back Box Model PresetsBack Exit Line Sync Line Sync Phase Back Exit Presets Preset NumberPreset 92 to 93 Scan limit stops Preset 94 Reserved Preset 83 to 87 ReservedPreset 95 Select main configuration menu Preset 96 Stop a scanSpace Label for Preset Preset NumberAbcdefghij Cancel Klmnopqrst Uvwxyz Edit Detection Areas Enable Motion DetectionMotion Detection Aux Time Activate Aux CommandEdit Schedule Back Exit PatternsBack Exit Patterns Back Exit Zones Zone Number ZonesEdit Zone Label Clear Zone Back ExitTo set a window blanking area Enable Window Reverse Clear Window Back ExitWindow Blanking Clear Window DisabledReverse Blanked Area Blank ALL ABOVE/BLANK ALL belowBlank All Above Blank All Below Alarms C3463M-B 2/11 Dwell Time Secs Edit Schedule Back Exit Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 ModeAUX Edit Title Text Title TextBack Exit Title Text Repeat AlertACK Action System Condition Alert MessageNone default Not activated Reset AlertActivate AUX Current ReadingBack Exit Password PasswordEnable Password Edit Password Back Abcdefghij Cancel Klmnopqrst Exit UvwxyzClock Follow the instructions in for Fixed DATE, adding Week Event Type EventBack Exit Event Event Type Event Label HolidayEdit Event Event LabelEdit Event Label List Event Clear EventHoliday Edit HolidayList Holidays Clear HolidayEdit Holiday Occurrence Month January DAY Back ExitUse this page to record scheduled events Example Preset Weekend 1100 AM Sat-SunScheduled Events Reset Camera Reset, Cycle Power, RebootCycle Camera Power Reboot SystemSoftware/Language File Upload Maintenance Signal Format Specifications23X Models Zoom Speed 4.2/5.8 seconds Horizontal Angle of ViewDD427 27X ModelsDD4CBW35 35X ModelsAppendix Table F. Switch Settings for SW1 Pelco P-Type ControlSpectra Switch Setting Address Table G. Switch Settings for SW1 Pelco D-Type Control 1Table G. Switch Settings for SW1 Pelco D-Type Control 2 Table G. Switch Settings for SW1 Pelco D-Type Control 3 Table G. Switch Settings for SW1 Pelco D-Type Control 4 Table G. Switch Settings for SW1 Pelco D-Type Control 5 Table G. Switch Settings for SW1 Pelco D-Type Control 6 Product Warranty and Return Information