Pelco C3463M-B manual System Information, DIP Switch Information

Page 20

System Information

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

SYSTEM INFORMATION

 

 

 

 

ADDITIONAL

SERIAL #

 

 

 

 

FREE MEMORY

DOME DRIVE MODEL

 

 

 

 

LAST RESET

BACK BOX MEMORY

 

 

 

 

AZIMUTH ZERO OFFSET

SOFTWARE VERSION

 

 

 

 

MOTOR ACTIVE

BUILD

 

 

 

 

CAMERA ACTIVE

FONT VERSION

 

 

 

 

VIDEO LEVEL

COMM

 

 

 

 

CAMERA MODEL

 

 

 

 

LANGUAGE 1

D ADDRESS

 

 

 

 

LANGUAGE 2

P ADDRESS

 

 

 

 

LANGUAGE 3

CM9500 MODE

 

 

 

 

LANGUAGE 4

32 PRESETS

 

 

 

 

LANGUAGE 5

PROTOCOL

 

 

 

 

LANGUAGE 6

PRESSURIZED*

 

 

 

 

LANGUAGE 7

<ADDITIONAL>

 

 

 

 

LANGUAGE 8

BACK

 

 

 

 

LANGUAGE 9

 

 

 

 

LANGUAGE 10

EXIT

 

 

 

 

<DIPSWITCH INFORMATION>

 

 

 

 

 

BACK

 

 

 

 

 

EXIT

The System Information menu displays the dome drive model, software version, available memory, DIP switch information, and other diagnostic information.

System settings cannot be changed using this menu; this information is for reference only.

Use the following steps to display the System Information menu:

1.Use the joystick to position the cursor beside SYSTEM INFORMATION.

2.Press Iris Open. The SYSTEM INFORMATION menu opens.

DIP SWITCH INFORMATION

The DIP Switch Information menu displays the dome drive’s current DIP switch settings. This provides a way to remotely view the DIP switch settings without removing the dome drive from the back box.

DIP SWITCH INFORMATION

 

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 9 0

]

SW1[- - - - - - - -

]

SW2[- - - - - - - - - -

SW1 1-8 :

D ADDRESS 1

P ADDRESS 1

SW2 1 : 32 PRESETS. OFF

SW2 2 : CM9500 MODE. OFF

SW2 3 : COAX SPIV

SW2 4-5 : RS422 <->

SW2 6-8 : COMM. 2400.N.8.1

SW2 9 : UTC SOURCE. COAX

SW2 10 : TX/RX TERM.. OFF

PRESS IRIS OPEN TO CONTINUE

*This setting applies to Pressurized Spectra IV dome systems only.

20

C3463M-B (2/11)

Image 20
Contents Spectra IV SL and Spectra IV SE Series Page Contents Field Align Page Description Installation Switch SettingsSW2 Switches 4 and 5 Serial Port Settings SW2 Switches 6 to 8 Baud SettingsDome Drive AddressQuick Operation Guide Quick Configuration GuideOperation Preset 95 Accessing Main Menu Extended Coaxitron or RS-485 ModeDigital Sentry DS Controlpoint Endura WorkstationDigital Sentry System Software 23X LowLight Day/Night Menu Tree Dome Settings Line Sync PresetsAlarms Password Edit the PasswordAlert Current Reading Clear Password 27X LowLight Day/Night Menu TreeLabel Position Patterns ZonesPower UP Line Sync Presets Motion Detection Event Edit Event35X LowLight Day/Night Menu Tree Azimuth Elevation Zoom Custom Camera Settings Spectra Language Reset Camera Cycle Camera Power Reboot System ExitLanguage DIP Switch Information System InformationRestore Factory Defaults Back Exit Display SetupExit Display Setup Preset Label Title Text Save and Exit Cancel Help Label PositionsEvent Alert MessageDome Settings CameraType of Lighting Auto FocusZoom Limit Zoom SpeedLOW Light Limit PT Focus LockLow Light Focus IR CUT FilterAuto IR Level Advanced Camera Settings Shutter SpeedAGC Limit Auto IrisAuto Sharpness Auto White BalanceBacklight Compensation Electronic Image StabilizationOFF Low lux noise reduction is disabled LOW LUX Noise ReductionVideo Level Field AlignMotion Settings LOW Light SharpnessMinimum Focus Distance Auto FlipPreset Freeze Frame Park TimeScan Speed Limit StopsPower UP Start Time Line Sync Zoom Presets Lost Action Auto TrackingAzimuth Zero Auto TrackingDisplay Setup SensitivityStart Time ZoomBack Exit Power UP Power UP Action Power UPPower UP Action Presets Table C. Stored Presets by Back Box ModelBack Exit Line Sync Line Sync Phase Back Exit Presets Preset NumberPreset 83 to 87 Reserved Preset 92 to 93 Scan limit stops Preset 94 ReservedPreset 95 Select main configuration menu Preset 96 Stop a scanSpace Label for Preset Preset NumberAbcdefghij Cancel Klmnopqrst Uvwxyz Edit Detection Areas Enable Motion DetectionMotion Detection Aux Time Activate Aux CommandEdit Schedule Back Exit PatternsBack Exit Patterns Zones Back Exit Zones Zone NumberEdit Zone Label Clear Zone Back ExitTo set a window blanking area Enable Window Reverse Clear Window Back ExitWindow Blanking Clear Window DisabledReverse Blanked Area Blank ALL ABOVE/BLANK ALL belowBlank All Above Blank All Below Alarms C3463M-B 2/11 Dwell Time Secs Edit Schedule Back Exit Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 ModeAUX Edit Title Text Title TextBack Exit Title Text Alert RepeatACK Action System Condition Alert MessageReset Alert None default Not activatedActivate AUX Current ReadingPassword Back Exit PasswordEnable Password Edit Password Back Abcdefghij Cancel Klmnopqrst Exit UvwxyzClock Follow the instructions in for Fixed DATE, adding Week Event Event TypeBack Exit Event Event Type Event Label HolidayEdit Event Event LabelEdit Event Label Clear Event List EventHoliday Edit HolidayClear Holiday List HolidaysEdit Holiday Occurrence Month January DAY Back ExitUse this page to record scheduled events Example Preset Weekend 1100 AM Sat-SunScheduled Events Reset, Cycle Power, Reboot Reset CameraCycle Camera Power Reboot SystemSoftware/Language File Upload Maintenance Specifications Signal Format23X Models Zoom Speed 4.2/5.8 seconds Horizontal Angle of View27X Models DD42735X Models DD4CBW35Table F. Switch Settings for SW1 Pelco P-Type Control AppendixTable G. Switch Settings for SW1 Pelco D-Type Control 1 Spectra Switch Setting AddressTable G. Switch Settings for SW1 Pelco D-Type Control 2 Table G. Switch Settings for SW1 Pelco D-Type Control 3 Table G. Switch Settings for SW1 Pelco D-Type Control 4 Table G. Switch Settings for SW1 Pelco D-Type Control 5 Table G. Switch Settings for SW1 Pelco D-Type Control 6 Product Warranty and Return Information