ALARMS

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA> <MOTION>

<AUTO TRACKING> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>

BACK

EXIT

ALARMS

 

 

 

 

ALARM SETTINGS

 

 

 

 

 

 

RESUME

 

 

 

 

ALARM NUMBER

SEQUENCE (SECS)

 

 

 

 

 

RESET DELAY (SECS)

 

 

 

 

ALARM PRIORITY

<ALARM SETTINGS>

 

 

 

 

ALARM ACTION

 

 

 

 

ACTIVATE AUX

BACK

 

 

 

 

ALARM CONTACT

 

 

 

 

<EDIT SCHEDULE>

EXIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BACK

 

 

 

 

 

EXIT

The 23X models have one alarm input available. The 27X and 35X models have seven alarm inputs. Alarm inputs can be configured as high, medium, or low priority. When an alarm is received, an input signal to the dome triggers the user-defined action (go to preset, run pattern, etc.) configured for the alarm.

NOTE: Refer to the notation in step 6 for the limited alarm features available for 23X models.

There are three global alarm settings:

RESUME: This mode lets the dome resume its previous activity (scan, pattern, or previous position) after all alarms are cleared.

SEQUENCE: This is the time the dome will perform an alarm activity when more than one alarm of the same priority occurs at the same time.

RESET DELAY: This is the amount of time the dome considers the alarm to be active after it has physically cleared.

Use the following steps to configure the alarm settings.

1.Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.

2.Select the alarm number:

a.Use the joystick to position the cursor beside ALARM NUMBER.

b.Press Iris Open. The cursor moves to the right.

c.Move the joystick up or down to view selections. Press Iris Open to enter selection.

3.Select the alarm priority:

a.Use the joystick to position the cursor beside ALARM PRIORITY.

b.Press Iris Open. The cursor moves to the right.

c.Move the joystick up or down to view the available selections. Available settings include HIGH, MEDIUM, and LOW (default). If multiple alarms with different priorities are active at the same time, the dome will only go to the alarms with the highest priority.

d.Press Iris Open to enter selection.

HIGH: Alarm action takes highest priority and will override manual PTZ control.

MEDIUM/LOW: Alarm action will not occur if an alarm occurs during manual pan, tilt, and zoom control.

*This setting applies to Pressurized Spectra IV dome systems only.

44

C3463M-B (2/11)

Image 44
Contents Spectra IV SL and Spectra IV SE Series Page Contents Field Align Page Description Installation Switch SettingsSW2 Switches 4 and 5 Serial Port Settings SW2 Switches 6 to 8 Baud SettingsDome Drive AddressQuick Operation Guide Quick Configuration GuideOperation Preset 95 Accessing Main Menu Extended Coaxitron or RS-485 ModeDigital Sentry DS Controlpoint Endura WorkstationDigital Sentry System Software 23X LowLight Day/Night Menu Tree Dome Settings Line Sync PresetsAlarms Password Edit the PasswordAlert Current Reading Clear Password 27X LowLight Day/Night Menu TreeLabel Position Patterns ZonesPower UP Line Sync Presets Motion Detection Event Edit Event35X LowLight Day/Night Menu Tree Azimuth Elevation Zoom Custom Camera Settings Spectra Language Reset Camera Cycle Camera Power Reboot System ExitLanguage DIP Switch Information System InformationRestore Factory Defaults Back Exit Display SetupExit Display Setup Preset Label Title Text Save and Exit Cancel Help Label PositionsEvent Alert MessageDome Settings CameraType of Lighting Auto FocusZoom Limit Zoom SpeedLOW Light Limit PT Focus LockLow Light Focus IR CUT FilterAuto IR Level Advanced Camera Settings Shutter SpeedAGC Limit Auto IrisAuto Sharpness Auto White BalanceBacklight Compensation Electronic Image StabilizationOFF Low lux noise reduction is disabled LOW LUX Noise ReductionVideo Level Field AlignMotion Settings LOW Light SharpnessMinimum Focus Distance Auto FlipPreset Freeze Frame Park TimeScan Speed Limit StopsPower UP Start Time Line Sync Zoom Presets Lost Action Auto TrackingAzimuth Zero Auto TrackingDisplay Setup SensitivityStart Time ZoomBack Exit Power UP Power UP Action Power UPPower UP Action Presets Table C. Stored Presets by Back Box ModelBack Exit Line Sync Line Sync Phase Back Exit Presets Preset NumberPreset 83 to 87 Reserved Preset 92 to 93 Scan limit stops Preset 94 ReservedPreset 95 Select main configuration menu Preset 96 Stop a scanSpace Label for Preset Preset NumberAbcdefghij Cancel Klmnopqrst Uvwxyz Edit Detection Areas Enable Motion DetectionMotion Detection Aux Time Activate Aux CommandEdit Schedule Back Exit PatternsBack Exit Patterns Zones Back Exit Zones Zone NumberEdit Zone Label Clear Zone Back ExitTo set a window blanking area Enable Window Reverse Clear Window Back ExitWindow Blanking Clear Window DisabledReverse Blanked Area Blank ALL ABOVE/BLANK ALL belowBlank All Above Blank All Below Alarms C3463M-B 2/11 Dwell Time Secs Edit Schedule Back Exit Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 ModeAUX Edit Title Text Title TextBack Exit Title Text Alert RepeatACK Action System Condition Alert MessageReset Alert None default Not activatedActivate AUX Current ReadingPassword Back Exit PasswordEnable Password Edit Password Back Abcdefghij Cancel Klmnopqrst Exit UvwxyzClock Follow the instructions in for Fixed DATE, adding Week Event Event TypeBack Exit Event Event Type Event Label HolidayEdit Event Event LabelEdit Event Label Clear Event List EventHoliday Edit HolidayClear Holiday List HolidaysEdit Holiday Occurrence Month January DAY Back ExitUse this page to record scheduled events Example Preset Weekend 1100 AM Sat-SunScheduled Events Reset, Cycle Power, Reboot Reset CameraCycle Camera Power Reboot SystemSoftware/Language File Upload Maintenance Specifications Signal Format23X Models Zoom Speed 4.2/5.8 seconds Horizontal Angle of View27X Models DD42735X Models DD4CBW35Table F. Switch Settings for SW1 Pelco P-Type Control AppendixTable G. Switch Settings for SW1 Pelco D-Type Control 1 Spectra Switch Setting AddressTable G. Switch Settings for SW1 Pelco D-Type Control 2 Table G. Switch Settings for SW1 Pelco D-Type Control 3 Table G. Switch Settings for SW1 Pelco D-Type Control 4 Table G. Switch Settings for SW1 Pelco D-Type Control 5 Table G. Switch Settings for SW1 Pelco D-Type Control 6 Product Warranty and Return Information