Pelco C3463M-B manual Exit Display Setup Preset Label, Restore Factory Defaults Back Exit

Page 21

Display Setup

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DISPLAY SETUP

PRESET LABEL

ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE DATE/TIME

EVENT LABEL <LABEL POSITIONS>

RESTORE FACTORY DEFAULTS BACK

EXIT

Display setup allows you to configure how labels are displayed on the monitor. The following labels are available:

PRESET LABEL: Identifies preset.

ZONE LABEL: Identifies zone.

ZOOM: Identifies the amount of magnification.

AZIMUTH/ELEVATION: Amount of pan from zero degrees vertical and the amount of tilt from zero degrees horizontal.

DIRECTION: Displays compass direction.

ALARM MESSAGE: Displays activated alarm.

DATE/TIME: Displays current date and time.

EVENT LABEL: Displays activated event.

A preset label is displayed when a preset is called. A zone label is displayed when the system moves into a zone. The zoom ratio label is displayed when zoom is activated. Azimuth/elevation and direction labels are displayed when pan/tilt is activated. An alarm message appears on the monitor when an alarm occurs. An event label appears on the monitor when an event occurs.

The following settings are available for each label except date and time:

OFF: Label is not displayed when activated.

CONSTANT: The label is continually displayed when activated.

2 SECONDS: The label is displayed for 2 seconds after activation.

5 SECONDS: The label is displayed for 5 seconds after activation.

10 SECONDS: The label is displayed for 10 seconds after activation.

The settings for date and time are ON or OFF.

*This setting applies to Pressurized Spectra IV dome systems only.

Azimuth is the pan angle from zero to 359 degrees.

Elevation is the tilt position from zero (horizon) to –90 degrees.

C3463M-B (2/11)

21

Image 21
Contents Spectra IV SL and Spectra IV SE Series Page Contents Field Align Page Description Switch Settings InstallationSW2 Switches 6 to 8 Baud Settings SW2 Switches 4 and 5 Serial Port SettingsAddress Dome DriveQuick Configuration Guide OperationQuick Operation Guide Extended Coaxitron or RS-485 Mode Preset 95 Accessing Main MenuEndura Workstation Digital Sentry System SoftwareDigital Sentry DS Controlpoint 23X LowLight Day/Night Menu Tree Line Sync Presets Dome SettingsAlarms Password Edit the Password27X LowLight Day/Night Menu Tree Alert Current Reading Clear PasswordLabel Position Patterns ZonesEvent Edit Event Power UP Line Sync Presets Motion Detection35X LowLight Day/Night Menu Tree Azimuth Elevation Zoom Custom Camera Settings Reset Camera Cycle Camera Power Reboot System Exit LanguageSpectra Language System Information DIP Switch InformationDisplay Setup Exit Display Setup Preset LabelRestore Factory Defaults Back Exit Label Positions Title Text Save and Exit Cancel HelpEvent Alert MessageCamera Dome SettingsType of Lighting Auto FocusZoom Speed Zoom LimitLOW Light Limit PT Focus LockIR CUT Filter Auto IR LevelLow Light Focus Shutter Speed Advanced Camera SettingsAGC Limit Auto IrisAuto White Balance Auto SharpnessBacklight Compensation Electronic Image StabilizationLOW LUX Noise Reduction OFF Low lux noise reduction is disabledVideo Level Field AlignLOW Light Sharpness Motion SettingsMinimum Focus Distance Auto FlipPark Time Preset Freeze FrameScan Speed Limit StopsAuto Tracking Power UP Start Time Line Sync Zoom Presets Lost ActionAzimuth Zero Auto TrackingSensitivity Display SetupStart Time ZoomPower UP Power UP ActionBack Exit Power UP Power UP Action Table C. Stored Presets by Back Box Model PresetsBack Exit Line Sync Line Sync Phase Back Exit Presets Preset NumberPreset 92 to 93 Scan limit stops Preset 94 Reserved Preset 83 to 87 ReservedPreset 95 Select main configuration menu Preset 96 Stop a scanLabel for Preset Preset Number Abcdefghij Cancel Klmnopqrst UvwxyzSpace Enable Motion Detection Motion DetectionEdit Detection Areas Activate Aux Command Edit ScheduleAux Time Patterns Back Exit PatternsBack Exit Back Exit Zones Zone Number ZonesEdit Zone Label Clear Zone Back ExitEnable Window Reverse Clear Window Back Exit Window BlankingTo set a window blanking area Disabled ReverseClear Window Blank ALL ABOVE/BLANK ALL below Blank All Above Blank All BelowBlanked Area Alarms C3463M-B 2/11 Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 Mode AUXDwell Time Secs Edit Schedule Back Exit Title Text Back Exit Title TextEdit Title Text Repeat AlertACK Action System Condition Alert MessageNone default Not activated Reset AlertActivate AUX Current ReadingBack Exit Password PasswordEnable Password Edit Password Back Abcdefghij Cancel Klmnopqrst Exit UvwxyzClock Follow the instructions in for Fixed DATE, adding Week Event Type EventBack Exit Event Event Type Event Label HolidayEvent Label Edit Event LabelEdit Event List Event Clear EventHoliday Edit HolidayList Holidays Clear HolidayEdit Holiday Occurrence Month January DAY Back ExitExample Preset Weekend 1100 AM Sat-Sun Scheduled EventsUse this page to record scheduled events Reset Camera Reset, Cycle Power, RebootCycle Camera Power Reboot SystemSoftware/Language File Upload Maintenance Signal Format Specifications23X Models Zoom Speed 4.2/5.8 seconds Horizontal Angle of ViewDD427 27X ModelsDD4CBW35 35X ModelsAppendix Table F. Switch Settings for SW1 Pelco P-Type ControlSpectra Switch Setting Address Table G. Switch Settings for SW1 Pelco D-Type Control 1Table G. Switch Settings for SW1 Pelco D-Type Control 2 Table G. Switch Settings for SW1 Pelco D-Type Control 3 Table G. Switch Settings for SW1 Pelco D-Type Control 4 Table G. Switch Settings for SW1 Pelco D-Type Control 5 Table G. Switch Settings for SW1 Pelco D-Type Control 6 Product Warranty and Return Information