Pelco C3463M-B manual 27X Models, DD427

Page 62

27X MODELS

DD427

Signal Format

Scanning System

Image Sensor

Effective Pixels

Horizontal Resolution

Lens

Zoom Speed (optical range)

Horizontal Angle of View

Focus

Maximum Sensitivity at 35 IRE

Sync System

White Balance

Shutter Speed

Iris Control

Gain Control

Video Output

Video Signal-to-Noise

Wide Dynamic Range

DD427-X

Signal Format

Scanning System

Image Sensor

Effective Pixels

Horizontal Resolution

Lens

Zoom Speed

Horizontal Angle of View

Focus

Maximum Sensitivity at 35 IRE

Sync System

White Balance

Shutter Speed

Iris Control

Gain Control

Video Output

Video Signal-to-Noise

Wide Dynamic Range

NTSC

2:1 Interlace/1:1 Progressive (user-selectable)

1/4-inch CCD

768 (H) X 494 (V)

>540 TV lines

f/1.4 (focal length, 3.4 ~ 119 mm; 35X optical zoom, 12X digital zoom)

3.2/4.6/6.6 seconds

55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom

Automatic with manual override

0.55lux at 1/60 sec shutter speed (color) 0.018 lux at 1/2 sec shutter speed (color) 0.00018 lux at 1/2 sec shutter speed (B-W)

Internal/AC line lock, phase adjustable using remote control, V-Sync

Automatic with manual override

Automatic (electronic iris)/manual; 1/2 ~ 1/30,000

Automatic iris control with manual override

Automatic/off

1Vp-p, 75 ohms >50 dB

128X

PAL

2:1 Interlace/1:1 Progressive (user-selectable)

1/4-inch CCD

752 (H) X 582 (V)

>540 TV lines

f/1.4 (focal length, 3.4 ~ 119 mm; 35X optical zoom, 12X digital zoom)

3.2/4.6/6.6 seconds

55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom

Automatic with manual override

0.45lux at 1/50 sec shutter speed (color) 0.015 lux at 1/1.5 sec shutter speed (color) 0.00015 lux at 1/1.5 sec shutter speed (B-W)

Internal/AC line lock, phase adjustable using remote control, V-Sync

Automatic with manual override

Automatic (electronic iris)/manual; 1/1.5 ~ 1/30,000

Automatic iris control with manual override

Automatic/off

1Vp-p, 75 ohms >50 dB

128X

62

C3463M-B (2/11)

Image 62
Contents Spectra IV SL and Spectra IV SE Series Page Contents Field Align Page Description Installation Switch SettingsSW2 Switches 4 and 5 Serial Port Settings SW2 Switches 6 to 8 Baud SettingsDome Drive AddressQuick Operation Guide Quick Configuration GuideOperation Preset 95 Accessing Main Menu Extended Coaxitron or RS-485 ModeDigital Sentry DS Controlpoint Endura WorkstationDigital Sentry System Software 23X LowLight Day/Night Menu Tree Alarms Dome SettingsLine Sync Presets Password Edit the PasswordLabel Position Alert Current Reading Clear Password27X LowLight Day/Night Menu Tree Patterns ZonesPower UP Line Sync Presets Motion Detection Event Edit Event35X LowLight Day/Night Menu Tree Azimuth Elevation Zoom Custom Camera Settings Spectra Language Reset Camera Cycle Camera Power Reboot System ExitLanguage DIP Switch Information System InformationRestore Factory Defaults Back Exit Display SetupExit Display Setup Preset Label Event Title Text Save and Exit Cancel HelpLabel Positions Alert MessageType of Lighting Dome SettingsCamera Auto FocusLOW Light Limit Zoom LimitZoom Speed PT Focus LockLow Light Focus IR CUT FilterAuto IR Level AGC Limit Advanced Camera SettingsShutter Speed Auto IrisBacklight Compensation Auto SharpnessAuto White Balance Electronic Image StabilizationVideo Level OFF Low lux noise reduction is disabledLOW LUX Noise Reduction Field AlignMinimum Focus Distance Motion SettingsLOW Light Sharpness Auto FlipScan Speed Preset Freeze FramePark Time Limit StopsAzimuth Zero Power UP Start Time Line Sync Zoom Presets Lost ActionAuto Tracking Auto TrackingStart Time Display SetupSensitivity ZoomBack Exit Power UP Power UP Action Power UPPower UP Action Back Exit Line Sync Line Sync Phase PresetsTable C. Stored Presets by Back Box Model Back Exit Presets Preset NumberPreset 95 Select main configuration menu Preset 83 to 87 ReservedPreset 92 to 93 Scan limit stops Preset 94 Reserved Preset 96 Stop a scanSpace Label for Preset Preset NumberAbcdefghij Cancel Klmnopqrst Uvwxyz Edit Detection Areas Enable Motion DetectionMotion Detection Aux Time Activate Aux CommandEdit Schedule Back Exit PatternsBack Exit Patterns Edit Zone Label ZonesBack Exit Zones Zone Number Clear Zone Back ExitTo set a window blanking area Enable Window Reverse Clear Window Back ExitWindow Blanking Clear Window DisabledReverse Blanked Area Blank ALL ABOVE/BLANK ALL belowBlank All Above Blank All Below Alarms C3463M-B 2/11 Dwell Time Secs Edit Schedule Back Exit Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 ModeAUX Edit Title Text Title TextBack Exit Title Text ACK Action AlertRepeat System Condition Alert MessageActivate AUX Reset AlertNone default Not activated Current ReadingEnable Password Edit Password PasswordBack Exit Password Back Abcdefghij Cancel Klmnopqrst Exit UvwxyzClock Follow the instructions in for Fixed DATE, adding Week Back Exit Event Event Type Event Label EventEvent Type HolidayEdit Event Event LabelEdit Event Label Holiday Clear EventList Event Edit HolidayEdit Holiday Occurrence Clear HolidayList Holidays Month January DAY Back ExitUse this page to record scheduled events Example Preset Weekend 1100 AM Sat-SunScheduled Events Cycle Camera Power Reset, Cycle Power, RebootReset Camera Reboot SystemSoftware/Language File Upload Maintenance 23X Models SpecificationsSignal Format Zoom Speed 4.2/5.8 seconds Horizontal Angle of View27X Models DD42735X Models DD4CBW35Table F. Switch Settings for SW1 Pelco P-Type Control AppendixTable G. Switch Settings for SW1 Pelco D-Type Control 1 Spectra Switch Setting AddressTable G. Switch Settings for SW1 Pelco D-Type Control 2 Table G. Switch Settings for SW1 Pelco D-Type Control 3 Table G. Switch Settings for SW1 Pelco D-Type Control 4 Table G. Switch Settings for SW1 Pelco D-Type Control 5 Table G. Switch Settings for SW1 Pelco D-Type Control 6 Product Warranty and Return Information