TC/CHR menu
Key | Key designation |
| Description |
F1 | SOURCE | INT: | |
| For selecting | EXT LTC: | LTC time code from TIME CODE input connector. |
| internal/external time code | S LTC: | LTC time code added to serial signals; not displayed |
| signal. |
| when the SD mode is selected. |
|
| S VTC: | VTC time code added to serial signals; not |
|
|
| displayed when the SD mode is selected. |
|
| EXT VITC: VITC time code added to video signals; not | |
|
|
| displayed when the HD mode is selected. |
F2 | TC SLAVE | ≥When the F1 (SOURCE) key is at [INT], AUTO, PRESET and | |
| For setting up time code | SALVE are displayed. | |
| slave lock mode. | AUTO: | Generator locks at the value read out by the |
|
|
| reader. In this case there is no time code setting. |
|
|
| (Only during editing.) During normal recording, |
|
|
| however, any setting of the generator can be |
|
|
| performed. |
|
| PRESET: Generator does not lock at the value read out by | |
|
|
| the reader. Generator can be set freely. |
|
| SLAVE: | The generator is locked to the reader’s readout |
|
|
| value. In this case, the time code cannot be set. |
|
| ≥When the F1 (SOURCE) key is at [TEXT LTC], SALVE and | |
|
| DIRECT are displayed. | |
|
| SLAVE: Generator locks to external LTC time code. | |
|
|
| (When there is no external input, |
|
|
| blinks. ) |
|
| DIRECT: External LTC time code is recorded as is. | |
|
|
| (When there is no external input, |
|
|
| ¢ ¢:¢ ¢ are displayed.) |
|
| ≥When the F1 key is at [S VITC], [S LTC] or [EXT VITC], this key | |
|
| is not displayed. | |
|
| In this case, the generator value typically locks to external VITC | |
|
| or LTC time code. | |
F3 | UB SLAVE | ON: User bit locks to user bit value read by reader (TCR) or to | |
| User bit lock. | external user bit value, and cannot be set. | |
|
| OFF: Generator does not lock to value read out by reader. User | |
|
| bit value can be set freely. | |
|
|
| |
F4 | RUN MD | REC RUN: Runs the TC only while recording is in progress. | |
| Time code progress. | FREE RUN: Runs the TC all the time in the same way as a | |
|
|
| clock. |
|
|
| |
F5 | DF MD° | Valid only when the F1 (SOURCE) key selects [INT]. | |
| For selecting drop or | ON: Drop frame mode is set. | |
| OFF: | ||
|
| ≥When [EXT LTC], [S VITC] or [S LTC] is selected in the F1 | |
|
| key, the VTR conforms to | |
|
| external time code. |
°This is not displayed when the 1080/23p, 1080/24p or 1080/50i system format has been selected.