AMX MVP-WDS manual Installation, Installing the CB-MVPWDS Conduit Box

Page 10

MVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box

Installation

MVP-WDS wall-docking stations can be installed either the CB-MVPWDS or other solid surface environment using one of the two mounting options: drywall clips or solid surface screws, as described in the following sub-sections.

Installing the CB-MVPWDS Conduit Box

The CB-MVPWDS (FG037-10) is a metallic conduit box that can be secured to a stud in a pre-wall setting. The MVP-WDS can then installed into the conduit box.

Installation procedures and configurations vary depending on the installation environment.

When mounting the conduit box, the MVP-WDS Mounting Tabs must lie flush against the outside of the sheetrock (FIG. 3).

Refer to installation diagram SP-5965-02for detailed installation dimensions.

It is recommended that you cut out the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments.

The CB-MVPWDS can be installed with the removable access panel positioned either on top or bottom. The access panel provides convenient access to in-wall wiring and must be re- installed prior to mounting the MVP-WDS.

1.Place the left side of the Conduit Box on a stud, making sure that five Stud Fastening Holes and removable Access Panel are oriented correctly (installation dependant). Be sure to leave enough of a gap between the stud and Mounting Tabs to accommodate the installation of the drywall or sheetrock after the conduit box has been mounted. Ultimately, the Mounting Tabs should lie flush against the outside of the sheetrock (FIG. 3).

Stud

Removable Access Panel

Stud Fastening Holes (5 located on left panel)

Wiring knockouts

(right side of conduit box)

Drywall or sheetrock

MVP-WDS mounting tabs (should lie flush against the outside of the wall)

FIG. 3 CB-MVPWDS conduit box components

4

MVP-WDS Wall Docking Station for MVP Panels

Image 10
Contents MVP-WDS AMX Limited Warranty and Disclaimer FCC Information Page Table of Contents Page MVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box OverviewSpecifications MVP-WDS SpecificationsMVP-WDS docking station connector locations LED IndicatorsInstallation Installing the CB-MVPWDS Conduit BoxRemoving the MVP-WDS Faceplate MVP Support CradleSecurity Latch Faceplate Securing Latches Faceplate Connectors Installing the MVP-WDS in a CB-MVPWDS Conduit Box Installing the MVP-WDS Using Expansion Clips MVP-WDS Wall Mount cutout dimensions using expansion clips Replacement drywall clip sets cab be ordered from AMX Screws not included Powering the MVP-WDS Connecting a Power SupplyReplacing the Faceplate on the MVP-WDS Using the 3.5mm mini-Phoenix Connector for Power Connecting and Using USB Input Devices on the StationsInterface Connector Pins and Functions Securing an MVP Panel to an MVP-WDSUnsecured MVP removal from an MVP-WDS Removing an MVP Panel from an MVP-WDSSecured MVP removal from an MVP-WDS Installing MVP-BP Batteries Into the MVP-WDS Installing and Charging Batteries in the Docking StationsUndock-USER String Installing the MVP-WDS-SK Silver Conversion Kit Removing the original faceplateSecurity Latch Faceplate securing latches Gap opening Installing the new conversion kit’s pivot unit components Removing the attached circuit boards a & BInstalling the new silver faceplate Installation of silver cradle pivot and battery coverMVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box Upgrading the Docking Station Firmware Prepare the Docking Station for firmware transfer via USBUpgrade the Docking Station firmware via USB Default Modero panel value isDevice and System values Upgrading the Docking Station Firmware Page It’s Your World Take Control