AMX MVP-WDS manual Using the 3.5mm mini-Phoenix Connector for Power

Page 20

MVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box

Initially, both blue LEDs illuminate and remain dim (indicating that the power is being supplied to the MVP-WDS).

Using the 3.5mm mini-Phoenix Connector for Power

To use the 2-pin 3.5 mm mini-Phoenix connector for use with a 12 VDC-compliant power supply, the incoming PWR and GND wires from the external source must be connected to their corresponding locations on the connector (FIG. 14) to provide power to the MVP-WDS.

PWR + GND -

PWR + GND -

MVP-WDS

Power Supply

FIG. 14 NetLinx power connector wiring diagram

Verify that the power supply is not receiving power.

1.Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm mini-Phoenix cable. Match the wiring locations of the +/- on both the power supply and the terminal connector.

2.Tighten the clamp to secure the two wires. Do not overtighten the screws - doing so could damage the wires.

3.Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the power supply, and apply power.

Connecting and Using USB Input Devices on the Stations

The MVP-WDS can have up to two USB input devices connected for use on the MVP panel’s different firmware and TPD4 panel pages. These input devices can consist of a keyboard and mouse.

USB-connected input devices are detected by the docking stations only after they are connected and then power is applied.

1.Remove the power connector from the docking station.

2.Insert the USB connectors of the peripheral input devices, into the appropriate USB connector on the docking station.

3.Reconnect the terminal power connector to the docking station and apply power.

4.Install the MVP panel onto the docking station.

5.Navigate to the Protected Setup page on the MVP panel and press the Reboot button to restart the panel. This step allows the MVP panel to detect the USB input devices signals being sent through the connected docking station.

The MVP does not recognize the keyboard and/or mouse (connected to the docking station) until after the MVP itself has been rebooted.

It does not matter if the MVP is on the docking station at the time the USB devices are plugged in or not.

The reboot of the panel has to occur after the MVP is properly connected and communicating with the docking station. In addition, if the MVP is removed from the docking station, the panel will not recognize the keyboard and/or mouse after it is put back on the docking station - the MVP will have to be rebooted again.

6.After the panel splash-screen disappears:

If a USB mouse has been connected, a mouse cursor appears on the panel screen and its location corresponds to the mouse cursor position sent by the external USB mouse.

14

MVP-WDS Wall Docking Station for MVP Panels

Image 20
Contents MVP-WDS AMX Limited Warranty and Disclaimer FCC Information Page Table of Contents Page MVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box OverviewSpecifications MVP-WDS SpecificationsMVP-WDS docking station connector locations LED IndicatorsInstallation Installing the CB-MVPWDS Conduit BoxRemoving the MVP-WDS Faceplate MVP Support CradleSecurity Latch Faceplate Securing Latches Faceplate Connectors Installing the MVP-WDS in a CB-MVPWDS Conduit Box Installing the MVP-WDS Using Expansion Clips MVP-WDS Wall Mount cutout dimensions using expansion clips Replacement drywall clip sets cab be ordered from AMX Screws not included Replacing the Faceplate on the MVP-WDS Connecting a Power SupplyPowering the MVP-WDS Using the 3.5mm mini-Phoenix Connector for Power Connecting and Using USB Input Devices on the StationsInterface Connector Pins and Functions Securing an MVP Panel to an MVP-WDSSecured MVP removal from an MVP-WDS Removing an MVP Panel from an MVP-WDSUnsecured MVP removal from an MVP-WDS Undock-USER String Installing and Charging Batteries in the Docking StationsInstalling MVP-BP Batteries Into the MVP-WDS Installing the MVP-WDS-SK Silver Conversion Kit Removing the original faceplateSecurity Latch Faceplate securing latches Gap opening Installing the new conversion kit’s pivot unit components Removing the attached circuit boards a & BInstalling the new silver faceplate Installation of silver cradle pivot and battery coverMVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box Upgrading the Docking Station Firmware Prepare the Docking Station for firmware transfer via USBUpgrade the Docking Station firmware via USB Default Modero panel value isDevice and System values Upgrading the Docking Station Firmware Page It’s Your World Take Control