AMX MVP-WDS manual Replacement drywall clip sets cab be ordered from AMX

Page 17

MVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box

Replacement drywall clip sets cab be ordered from AMX.

6.Tighten all four drywall clip sets (screws and clips) until both Mounting Tabs are securely fastened and flush against the wall.

7.Follow the steps outlined in the Replacing the Faceplate on the MVP-WDSsection on page 13 to angle the MVP Support Cradle forward and re-install the faceplate.

Installing the MVP-WDS Into a Flat Surface Using Mounting Screws

Use #4-40 Mounting screws (not included) to mount the WDS to a flat surface, through the two sets of holes located on the sides of the WDS.

Refer to SP-5965-01for detailed installation dimensions (reproduced in FIG. 12).

It is recommended that you cutout the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments.

The outer frame Mounting Tabs must be installed so thatthey are flush against the mounting surface.

1.Cut out the surface for the MVP-WDS docking station using the dimensions shown in FIG. 12.

 

 

12.70 [323MM] BEZEL OUTLINE

.52 [13MM] TYP

11.06 [281MM]

 

 

FRONT BEZEL OUTLINE

 

 

 

 

1.19 [30MM] TYP

 

 

 

R.13 [3.2MM] MAX RADIUS IN 4 CORNERS

 

 

THESE 4 HOLES ARE ONLY REQUIRED

 

 

WHEN MOUNTING UNIT TO A SOLID

 

 

SURFACE (PODIUM, DESK, ETC).

 

 

SECURE UNIT WITH #4 SCREWS

7.91 [201MM]

5.54 [141MM]

8.63 [219MM]

BEZEL OUTLINE

 

 

CUTOUT

12.10 [307MM]

FIG. 12 MVP-WDS Wall Mount cutout dimensions using solid surface screws

2.Thread the USB and Power cables through the surface opening, leaving enough slack in the wiring to accommodate any re-positioning of the unit.

3.Connect the 2-pin power connector and USB cables along the right side of the (un-powered) MVP-WDS. The faceplate must be removed prior to any surface installation.

MVP-WDS Wall Docking Station for MVP Panels

11

 

 

Image 17
Contents MVP-WDS AMX Limited Warranty and Disclaimer FCC Information Page Table of Contents Page Overview MVP-WDS Wall Docking Station & CB-MVPWDS Conduit BoxMVP-WDS Specifications SpecificationsLED Indicators MVP-WDS docking station connector locationsInstalling the CB-MVPWDS Conduit Box InstallationMVP Support Cradle Removing the MVP-WDS FaceplateSecurity Latch Faceplate Securing Latches Faceplate Connectors Installing the MVP-WDS in a CB-MVPWDS Conduit Box Installing the MVP-WDS Using Expansion Clips MVP-WDS Wall Mount cutout dimensions using expansion clips Replacement drywall clip sets cab be ordered from AMX Screws not included Replacing the Faceplate on the MVP-WDS Connecting a Power SupplyPowering the MVP-WDS Connecting and Using USB Input Devices on the Stations Using the 3.5mm mini-Phoenix Connector for PowerSecuring an MVP Panel to an MVP-WDS Interface Connector Pins and FunctionsSecured MVP removal from an MVP-WDS Removing an MVP Panel from an MVP-WDSUnsecured MVP removal from an MVP-WDS Undock-USER String Installing and Charging Batteries in the Docking StationsInstalling MVP-BP Batteries Into the MVP-WDS Removing the original faceplate Installing the MVP-WDS-SK Silver Conversion KitSecurity Latch Faceplate securing latches Gap opening Removing the attached circuit boards a & B Installing the new conversion kit’s pivot unit componentsInstallation of silver cradle pivot and battery cover Installing the new silver faceplateMVP-WDS Wall Docking Station & CB-MVPWDS Conduit Box Prepare the Docking Station for firmware transfer via USB Upgrading the Docking Station FirmwareDefault Modero panel value is Upgrade the Docking Station firmware via USBDevice and System values Upgrading the Docking Station Firmware Page It’s Your World Take Control