Motorola i860 manual BER Test, Fail

Page 86

FIELD LEVEL TEST MODES AND PROCEDURES: BER Test

8.7BER Test

Use this test on a unit having any of the following symptoms: resets (RAAAA Type), No Service failures.

Set up the R-2660 for iDEN BER Test, and connect the unit to the RF IN/OUT connector.

Connect the battery eliminator to the unit. Remove the antenna. Set power supply between 5.0 and 12.0 Vdc.

Notes:

1.Confirm the reset log has errors.

2.Place the unit into Test Mode for this test.

3.Watch the unit for resetting during this procedure.

4.Verify the R-2660 has been calibrated and cable continuity is good.

5.In the United States, the Main board can only be replaced and programmed at the factory or iDEN Radio Support Center.

6.The Power, MPX, and MOD test parameters are for factory use only and should not be adjusted by field service personnel (see page 7-2 for default values).

Power up the unit. Enter test mode.

Do the following:

1.Press the Menu key, and then the Edit option key.

2.Press the Change option key, and scroll down to 800BER1.

3.Press Select to select the test.

4.Press the Back key, and then press Menu.

The monitor frequency is 806.0125 (Carr#1) for BER1.

Press Start

 

 

 

 

 

 

 

on unit. Press TX ON. The

 

 

 

 

 

 

 

 

Fail

 

 

Replace the

 

 

 

 

 

RX BER that appears on the display

 

 

 

 

 

Main board, and

 

should be 0.0% at -70 dBm. Verify that

 

 

 

 

 

 

 

 

 

repeat the test.

 

 

 

 

 

 

the TX BER on the R-2660

 

 

 

 

 

 

 

 

 

 

 

 

 

is <

0.07%.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pass

 

Note: Ensure that the maximum cable

 

 

 

 

Lower

loss does not exceed 2 dB.

 

 

Gen: to -109 dBm

 

 

 

 

 

 

 

and check the RX BER in the

Fail

display. The BER should be less than 10%

 

when at Gen: -109 dBm. (Freq

 

 

Error should be less

 

than 200 Hz.)

 

Pass

 

 

 

 

 

Replace the

Main board, and

repeat the test.

Repeat the

above test using

800BER2, 800BER3,

800BER4; 900BER1, 900BER2,

 

 

 

 

 

 

 

and 900BER3 in test mode.

 

 

 

 

 

 

 

The monitor frequency is 813.5125

 

Fail

 

 

 

Replace the

 

 

 

 

 

 

(Carr#601) for 800BER2, 820.9875 (Carr#1199)

 

 

 

Main board, and

 

 

 

 

 

 

for 800BER3, and 824.9875 for 800BER4.

 

 

 

 

repeat the test.

 

The monitor frequency is 896.01875 for

 

 

 

 

 

 

 

 

 

 

 

 

900BER1, 898.51875 for

 

 

 

 

 

 

 

Pass

 

 

 

 

 

 

 

900BER2 and

Note: Change offset on R2660 to +39 MHz for 900

900.98125 for

900BER3.

MHz (900BER1, 900BER2, and 900BER3).

Unit passed test. Look for system,

coverage, accessory, or software problems.

68P80400P73-A

8-7

Image 86
Contents Page I860 Manual Revisions Safety and General Information Electro Magnetic Interference Compatibility Medical DevicesAccessory Safety Information Cleaning and Drying ConsiderationsSafety and General Information Model Information Model Numbering SystemModel Specifications General Receiver TransmitterContents Chapter Chapter Field Level Test Modes Procedures Appendix a Ordering Replacement Parts How This Manual Is Organized PrefaceWho Should Use This Manual Conventions Used in This Manual Related PublicationsOverview DEN Digital Modulation TechnologySpectrum of i DEN Quad 16QAM DEN Voice Compression Technology RF Transmission BurstsCalling Area Coverage Removing and Inserting a SIM Card Global Positioning System GPS SectionSIM Cards To remove a SIM card Figure To insert a SIM card FigureCOMPONENTS, ICONS, and Indicators Component ViewsDisplay Icons Main Menu IconsAbc d efg d Opqr s Status IconsDEF Call IconsContacts Type Icons Outbox IconsThis page intentionally left blank Power-Up Sequence DISPLAYS, MESSAGES, and AlertsSelf-Test Reset Errors Power-Down SequenceSelf-Test Errors MessagesMessage Cause Action Service MessagesService Messages Alert Tones Tone Low High Freq Cadence When Tone OccursAlert Tones Alert Tones Mode Cadence Using the Optional Vibrate FunctionVibrator Settings To set unit to vibrate for all callsFrom the main menu, select Settings 2-Way Radio Alert Type This page intentionally left blank Test Equipment Preparing for Basic Level TestingReference Accessories Reference UnitThis page intentionally left blank Customer Care Reset ConditionBasic Level Checks and Self Tests Test ConditionsBasic-Level Test Checklist Basic-Level Test ChecklistPreventive Maintenance To clean the unit approximately 3 minutesShock and pressure test time is approximately 3 minutes Mechanical and Electrical ChecksSIM Card Swap Test SIM card swap test time is approximately 5 minutesLockup Test Accessory Swap TestAccessory swap test time is approximately 5 minutes Lockup test time is approximately 6 minutesBattery connections test time is approximately 5 minutes Battery Connections TestTesting the GPS Receiver To test this functionVoltage recognition test time is approximately 4 minutes Voltage Recognition TestCamera Test Passcode Test TroubleshootingSelf-Test Procedures Passcode test time is approximately 5 minutesPhone Calls Features Programming Menu Settings CheckSettings check test time is approximately 10 minutes Way Radio Options Volume Features PersonalizeSecurity Features From the main menu, select Settings Security SIM PINAdvanced Features From the main menu, select Settings Advanced Headset/SpkerCall Performance Test Call performance test time is approximately 7 minutesThis page intentionally left blank To enter debug mode Basic Level Test Modes and ProceduresEntering Debug Mode Test ModesName Description Display ScreensDisplay Screens Entering Test Mode To enter test modeTo perform the audio loopback test test time approx min Test Mode Test ProceduresAudio Loopback Test To perform the matching test test time approx min ESN and Imei Matching TestEngineering Debug Check To monitor the data in the unitSoftware choice 68P80400P73-A Technician Test Procedures Programming the i 860 UnitConnecting the Unit to the RSS Workstation Data Cable Programming SetupTo access the codeplug Help topic in Windows Codeplug Repair ProcedureCodeplug Troubleshooting Preparing for Field Level Testing Preparing Equipment for TestingUsing RSS Connecting an i DEN Unit to the R-2660To connect the unit to the R-2660 Coaxial Cable In/Out TypeRF Zone Fields and Values To enter Initial Registration modeOperating the R-2660 Field ValueDisassembling and Reassembling the Unit SIM Card Battery CoverInstall RemoveAntenna Required Tools T-4 Torx bitBack Housing Coin Cell Required Tools Black stickMain Board, Microphone Seal, and Keypad Flip Assembly Remove Flip AssemblyPage Install Page Exploded View and Parts List Description Part Number Reference Component Parts ListComponent List Exploded View This page intentionally left blank Field Level Test Modes and Procedures Field-Level Test Checklist Required Test EquipmentField-Level Test Checklist Done Technical Tests Pass FailSee the Strong Signal Environment section Registration/Call TestSQE Reference Chart SQE TestTX Power Test See Entering Test Mode Press Menu, EditBER Test FailPower-Up Test Keypad Test Audio Test Use this test to check the audio portion of the unitReset Test No reset ResetReset Log Test To perform the reset log testModel Assembly MA Test Mode Test Model Assembly MA Test Mode Test GPS Receiver Use this test on a unit to check functionality of the GPSCamera Test Replacement Parts Ordering Replacement Parts and KitsCustomer Service Domestic OrdersDescription Kit Number Replacement KitsTable A-2. i 860 Replacement Kits Vehicle Power Adapters Description Part Number Recommended Test Equipment and ToolsTable A-3. Recommended Test Equipment and Tools Table A-5. Recommended Software Recommended Programming EquipmentTable A-4. Recommended Programming Equipment Name Part Number DescriptionThis page intentionally left blank Index BcchQAM RSS Vselp @6880400P73@