Motorola i860 manual Reset Test, No reset Reset

Page 90

FIELD LEVEL TEST MODES AND PROCEDURES: Reset Test

8.11Reset Test

Use this test on a unit having any of the following symptoms: unit resets, or unit powers off and then on.

Set up the R-2660 for iDEN Mobile operation, and connect the unit to the RF IN/OUT connector.

Power up the unit.

Enter Initial Registration mode (see Operating the R-2660).

Notes:

1.Verify that the unit has resets entries in the Reset log. See the Reset Log Test.

2.Try to duplicate the failure.

3.Record information pertaining to the failure.

4.Monitor the unit at all times for visual resetting.

5.Make sure the R-2660 is set to a frequency in the unit bandmap.

Place

unit in lock (press

Menu, Settings, Security,

Phone Lock) and complete an interconnect call. Leave call connected for several minutes.

Pass

Increase

attenuation 10 dB

at a time to confirm operation in a weak-signal environment.

See the SQE Reference

chart.

Pass

Reset

 

 

Replace the

 

 

 

 

 

 

Main board, and

 

 

 

 

 

 

 

 

repeat test.

 

 

 

 

 

 

Reset

 

 

Replace the

 

 

 

 

 

 

Main board, and

 

 

 

 

 

 

 

 

repeat test.

 

 

 

 

 

 

SQE Reference Chart

Gen

SQE Level

-70 dBm

>26

-80 dBm

>25

-90 dBm

>23

-100 dBm

>20

Note: Gen levels in the SQE chart include RF Adapter losses.

Tap the

front (face) of the

unit with your

fingers.

No reset

Reset

 

 

Replace the

 

 

 

 

 

 

Main board, and

 

 

 

 

 

 

 

 

repeat test.

 

 

 

 

 

 

Unit passed test.

68P80400P73-A

8-11

Image 90
Contents Page I860 Manual Revisions Safety and General Information Electro Magnetic Interference Compatibility Medical DevicesAccessory Safety Information Cleaning and Drying ConsiderationsSafety and General Information Model Information Model Numbering SystemModel Specifications General Receiver TransmitterContents Chapter Chapter Field Level Test Modes Procedures Appendix a Ordering Replacement Parts Preface Who Should Use This ManualHow This Manual Is Organized Conventions Used in This Manual Related PublicationsOverview DEN Digital Modulation TechnologySpectrum of i DEN Quad 16QAM DEN Voice Compression Technology RF Transmission BurstsCalling Area Coverage Global Positioning System GPS Section SIM CardsRemoving and Inserting a SIM Card To remove a SIM card Figure To insert a SIM card FigureCOMPONENTS, ICONS, and Indicators Component ViewsDisplay Icons Main Menu IconsAbc d efg d Opqr s Status IconsDEF Call IconsContacts Type Icons Outbox IconsThis page intentionally left blank Power-Up Sequence DISPLAYS, MESSAGES, and AlertsSelf-Test Reset Errors Power-Down SequenceSelf-Test Errors MessagesService Messages Service MessagesMessage Cause Action Tone Low High Freq Cadence When Tone Occurs Alert TonesAlert Tones Alert Tones Mode Cadence Using the Optional Vibrate FunctionVibrator Settings To set unit to vibrate for all callsFrom the main menu, select Settings 2-Way Radio Alert Type This page intentionally left blank Test Equipment Preparing for Basic Level TestingReference Accessories Reference UnitThis page intentionally left blank Customer Care Reset ConditionBasic Level Checks and Self Tests Test ConditionsBasic-Level Test Checklist Basic-Level Test ChecklistPreventive Maintenance To clean the unit approximately 3 minutesShock and pressure test time is approximately 3 minutes Mechanical and Electrical ChecksSIM Card Swap Test SIM card swap test time is approximately 5 minutesLockup Test Accessory Swap TestAccessory swap test time is approximately 5 minutes Lockup test time is approximately 6 minutesBattery connections test time is approximately 5 minutes Battery Connections TestTesting the GPS Receiver To test this functionVoltage Recognition Test Camera TestVoltage recognition test time is approximately 4 minutes Passcode Test TroubleshootingSelf-Test Procedures Passcode test time is approximately 5 minutesProgramming Menu Settings Check Settings check test time is approximately 10 minutesPhone Calls Features Way Radio Options Volume Features PersonalizeSecurity Features From the main menu, select Settings Security SIM PINAdvanced Features From the main menu, select Settings Advanced Headset/SpkerCall Performance Test Call performance test time is approximately 7 minutesThis page intentionally left blank To enter debug mode Basic Level Test Modes and ProceduresEntering Debug Mode Test ModesDisplay Screens Display ScreensName Description Entering Test Mode To enter test modeTest Mode Test Procedures Audio Loopback TestTo perform the audio loopback test test time approx min To perform the matching test test time approx min ESN and Imei Matching TestEngineering Debug Check To monitor the data in the unitSoftware choice 68P80400P73-A Technician Test Procedures Programming the i 860 UnitConnecting the Unit to the RSS Workstation Data Cable Programming SetupCodeplug Repair Procedure Codeplug TroubleshootingTo access the codeplug Help topic in Windows Preparing for Field Level Testing Preparing Equipment for TestingUsing RSS Connecting an i DEN Unit to the R-2660To connect the unit to the R-2660 Coaxial Cable In/Out TypeRF Zone Fields and Values To enter Initial Registration modeOperating the R-2660 Field ValueDisassembling and Reassembling the Unit SIM Card Battery CoverInstall RemoveAntenna Required Tools T-4 Torx bitBack Housing Coin Cell Required Tools Black stickMain Board, Microphone Seal, and Keypad Flip Assembly Remove Flip AssemblyPage Install Page Exploded View and Parts List Component Parts List Component ListDescription Part Number Reference Exploded View This page intentionally left blank Field Level Test Modes and Procedures Field-Level Test Checklist Required Test EquipmentField-Level Test Checklist Done Technical Tests Pass FailSee the Strong Signal Environment section Registration/Call TestSQE Reference Chart SQE TestTX Power Test See Entering Test Mode Press Menu, EditBER Test FailPower-Up Test Keypad Test Audio Test Use this test to check the audio portion of the unitReset Test No reset ResetReset Log Test To perform the reset log testModel Assembly MA Test Mode Test Model Assembly MA Test Mode Test GPS Receiver Use this test on a unit to check functionality of the GPSCamera Test Replacement Parts Ordering Replacement Parts and KitsCustomer Service Domestic OrdersReplacement Kits Table A-2. i 860 Replacement KitsDescription Kit Number Vehicle Power Adapters Recommended Test Equipment and Tools Table A-3. Recommended Test Equipment and ToolsDescription Part Number Table A-5. Recommended Software Recommended Programming EquipmentTable A-4. Recommended Programming Equipment Name Part Number DescriptionThis page intentionally left blank Index BcchQAM RSS Vselp @6880400P73@