Step 21.

Install the CSAFE power connector on the new bottom plastic cover.

Step 23.

Take the front display plastics with the new cen- ter console to the base unit. Hold the front dis- play plastics at the top with one hand while con- necting the cables/harnesses with the other.

34

Step 22.

Install the new bottom plastic cover onto display, use the screws saved from the earlier step to secure the display bottom. Tighten the screws so they are snug, then plug in the CSAFE power cable to the back of the display.

Note: Take special care to not pinch any of the ca- bles between the plastics.

3

2

4

1

Step 24.

Identify the four cables coming out of the neck and mounting bracket:

1.Heart rate cable.

2.Main I/O cable.

3.Coax cable.

4.DC power cable.

Note: The coax and DC power cables are part of the PVS and embedded kits and should be tucked down the neck for possible future use.

620-7921 Rev A

Image 33
Contents Work Instructions General Unpacking Instructions Verify the following tools are included in the kit Installation Instructions Step Rev a Step YOU have NOW Completed the Total Body Trainer Installation Rev a Embedded Display Console Installation Instructions Rev a Before After Step Step YOU have NOW Completed the Embedded Display Installation Rev a IPod Center Console Installation Instructions Now disconnect the heart rate connector from the display Step Step Step Before After Step Step YOU have NOW Completed the iPod Center Console Installation Rev a MYE Entertainment Center Console Installation Instructions Disconnect the 12-pin serial connector from the display Rev a Step Step Step Step YOU have NOW Completed the MYE Center Console Installation Rev a Personal Viewing Screen PVS Installation Instructions Now disconnect the heart rate connector from the display Screws Step Rev a Tie the iPod cable to the plastic using the 3.5 tie wrap Rev a From PVS Neck From Base Neck Tie Wrap Step Rev a Step Rev a Star Trac Star Trac FitnessTM Manager / Maintenance Mode PB-UB Troubleshooting