Precor C842i owner manual Self-Powered Features, Informational Displays Prior to Shutdown

Page 8

Self-Powered Features

The power source for the cycle is the user. When a person maintains a pedal speed above 20 revolutions per minute (RPM), the power that is generated allows the cycle to function properly.

Informational displays appear when the battery is low or when the user reduces the pedal speed below the minimum requirement. The display explains what to do to retain power. If the messages are ignored, the cycle begins shutdown procedures to maintain the charge of the battery. Refer to Informational Displays Prior to

Note: If the cycle is connected to a CSAFE master device, a slightly different scenario occurs. When ten seconds remain before the cycle shuts off, the workout session ends. RESETTING appears in the lower display while the cycle disconnects from the CSAFE master device. All key presses are ignored. pedaling has no effect on the display.

Shutdown.

An optional power adapter can be purchased and provides sustained power to the cycle. If you plan to customize your unit, the power adapter is highly recommended. To purchase the optional power adapter, check with your dealer. Refer to Obtaining Service.

C846i

Cardiovascular

Above

Heart Rate

 

 

 

Weight Loss

Below

Option 1

PRESS

Option 2 - programs

PRESS ENTER

Use arrows (or numeric keys) to display:

PROGRAM (press ENTER to select)

TIME (press ENTER to select)

WEIGHT (press ENTER to select)

AGE (press ENTER to select)

CAUTION

Before beginning any fitness program, you should have a complete physical examination by your physician. Consult your physician for the heart rate appropriate for your fitness level. If you feel pain, faint or dizzy, stop exercising immediately. Keep hands and clothing away from moving parts. Do not allow children and people unfamiliar with operation on or near the unit.

Informational Displays Prior to Shutdown

The cycle saves its battery charge by moving into a shutdown mode. Whenever PEDAL FASTER appears on the display, the heart rate, SmartRate® and program indicators turn off. If the user does not maintain a pedal speed of 20 RPM, then a 20-second shutdown process begins.

When 28 seconds remain, 28 dots appear in the center display. All key presses are ignored except RESET. If no one begins pedaling, a dot disappears every second as the countdown continues.

Note: The user can resume exercising if he or she begins pedaling before the 28-second period elapses.

TIME

DISTANCE

 

RPM

 

CALORIES

 

 

REMAINING TIME

SPEED

 

METS

 

WATTS

SEGMENT TIME

RESISTANCE

 

AVERAGE SPEED

 

CAL PER MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROGRAM CHANG E

QUICKSTART

Diagram 2: C846i display

Product Owner’s Manual: Self-Powered Features

6

Image 8
Contents C842i C846i Page Important Safety Instructions Radio Frequency Interference RFI Safety ApprovalHazardous Materials and Proper Disposal Canadian Department Communications European ApplicationsObtaining Service Diagram 1 Location of serial numberTable of Contents Informational Displays Prior to Shutdown Self-Powered FeaturesDiagram 2 C846i display Replacing the Battery Symptoms of a Low BatteryOptional Power Adapter Club Features Club Programming TipsSelecting a U.S. Standard or Metric Display Diagram 3 C842i display and keypad numbersChoosing a Language Setting a Workout Time Limit Setting a Pause Time LimitSetting a Resistance Range C846i HighDiagram 4 Modify the Custom program Changing the Custom ProgramInformational Displays C842i Viewing the OdometerViewing the Error Log Diagram 5 Error logInformational Displays C846i Diagram 6 Error log Revs 17 HrSUser ID Entry with Csafe Equipment Displaying the Serial NumberPage Maintenance Daily CleaningCleaning the Equipment Daily InspectionLong-Term Storage Adjusting the SeatDiagram 7 Adjusting the seat on the C842i Upright Cycle Diagram 9 Loosen nut to adjust seat tilt Upright Cycles Adjusting the Seat TiltDiagram 8 Adjusting the seat on the C842i Recumbent Cycle Recumbent Cycles Realigning the Seat Diagram 10 Tilt the seat forward or backwardDiagram 11 Loosen the two adjustment screws Diagram 13 Optional power adapter receptacle Using the Optional Power AdapterDiagram 12 Wheel lock adjustment Erratic heart rate readings Troubleshooting Error CodesTroubleshooting Heart Rate Precor Commercial Equipment Limited Warranty Warranty Periods and CoverageExclusion of Consequential and Incidental Damages Thank You and Welcome to Precor Tell US about Your NEW Precor Products Page Product Specifications C842i/C846i Commercial CyclesC846i Page Important Safety Instructions Heart Rate Features Display ConsoleCycle Features Self-Powered Features0 0 Using the HandlebarsStoring Workout Statistics Heart Rate Features Diagram 3 Heart rate target zonesGuidelines Your Heart Rate 200 190 180 170 160 150 140 130 120 110 100Using the Heart Rate Touch-Sensitive Grips Diagram 4 Touch-sensitive handlebar gripsUsing SmartRate Heart rate target zones and SmartRate LEDsExercise to Your Target Heart Rate Heart Rate AnalysisDisplay Console C846iMore Information about the Lower Display Diagram 5 Column height in the program profileMore Information about the Center Display Column 2 DISTANCE, SPEED, and Resistance Keypad Workout Options C846iChoosing Quickstart Selecting a Program Changing the Program during an Exercise Session Cooling Down After a Workout Pausing During a Workout or the Cool-Down Period Ending a WorkoutChoosing a Program Diagram 6 C846i program labelPrograms N u a l t i m e g o a l Program TipsManual Program Cross Country Program Hill ProgramO s s c o u n t r y L l p r o g r a m1 i n t e r v a l p r o g r a m Random ProgramInterval Programs 5, 6, Watts Control Program Heart Rate Control ProgramT t s c o n t r o l A r t r a t e c o n t r o lE i g h t l o s s p r o g r a m Weight Loss ProgramRest interval Custom Resistance Program U s t o m r e s i s t a n c eDistance Program Calories ProgramI s t a n c e g o a l A l o r i e s g o a lFitness Test I t n e s s t e s tCompleting the Fitness Test Cardiorespiratory fitness score category-femalesUser’s Reference Manual Programs Page C846i URM 48819-101, en 15 July Assembly Guide Page Required Tools Obtaining Service Unpacking the EquipmentInstallation Requirements Hardware Kit not to scale Fasteners QuantityAssembly Steps Page Height adjusters Precor Incorporated 20031 142nd Avenue NE Box