Whirlpool W10057260 Dryer Dimensions, Recommended installation spacing for cabinet installation

Page 6

Dryer Dimensions

36"

(91.4 cm)

*28.65" (72.77 cm)

50¹⁄₂"

(128.27 cm)

27"

Recessed or closet installation - Dryer on pedestal

 

 

 

 

 

14" max.*

 

 

 

 

 

(35.6 cm)

 

 

 

 

15" min.*

 

 

 

 

(38.1 cm)

1"

27"

1"

1"*

28.65"

5"**

(2.5 cm)

(68.6 cm)

(2.5 cm)

(2.5 cm)

(72.77 cm) (12.7 cm)

(68.6 cm)

*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer only

 

 

2"*

 

 

(5 cm)

36" min

 

 

(91.4 cm)

 

 

1"*

27"

1"*

(2.5 cm)

(68.6 cm)

(2.5 cm)

*Required spacing

Closet installation - Dryer only

AB

A. Recessed area

B. Side view - closet or confined area

*Required spacing

**For side or bottom venting, 0" (0 cm) spacing is allowed.

Recommended installation spacing for cabinet installation

For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.

7"* (17.8 cm)

7"* (17.8 cm)

9"*

(22.9 cm)

5"**

28.65"

1"*

1"

27"

1"

(12.7 cm)

(72.77 cm) (2.5 cm) (2.5 cm)(68.6 cm) (2.5 cm)

*Required spacing

**For side or bottom venting, 0" (0 cm) spacing is allowed.

 

 

14" max.*

 

 

 

(35.6 cm)

48 in.2*

 

 

 

(310 cm2)

 

15" min.*

 

 

(38.1 cm)

 

 

 

 

24 in.2*

 

 

 

(155 cm2)

1"*

28.65"

5"**

 

(2.5 cm) (72.77 cm)(12.7 cm)

 

 

A

 

 

3"*

(7.6 cm)

3"*

(7.6 cm)

B

A. Side view - closet or confined area

B. Closet door with vents

*Required spacing

**For side or bottom venting, 0" (0 cm) spacing is allowed.

6

Image 6
Contents Electronic GAS Dryer W10057260Table DES Matières Dryer Safety Your safety and the safety of others are very importantParts supplied Installation InstructionsTools andParts Parts neededLocationRequirements OptionalPedestalRecessed or closet installation Dryer on pedestal Dryer DimensionsRecommended installation spacing for cabinet installation Custom undercounter installation Dryer onlyMobile home additional installation requirements Mobile home installations requireElectrical Requirements Gas Type Gas supply pressure testingGasSupplyRequirements Gas supply connection requirementsDryer gas pipe If using an existing vent systemVentingRequirements If this is a new vent system Vent materialPlan VentSystem Optional exhaust installationsAlternate installations for close clearances ExhaustSpecial provisions for mobile home installations Install VentSystemInstall LevelingLegs Vent system chartLevelDryer MakeGasConnectionConnectVent For mobile home useRemove the door assembly ReverseDoorSwingReverse hinge Reverse the strike CompleteInstallationReinstall the door If the dryer will not start, check the followingDryer USE StartingYourDryerTo use an Auto Cycle DryingandCycleTips StoppingorRestartingYourDryerLockControls StatusLightsCycles AdditionalFeatures ChangingCycles,OptionsandModifiersDryingRackOption Every load cleaning CleaningtheDryerLocationCleaningtheLintScreen As needed cleaningRemovingAccumulatedLint TroubleshootingCleaningtheDryerInterior VacationandMovingCareDryerResults Dryer displaying code messageCycle time too short Assistance or Service TheU.S.AInCanada Whirlpool Corporation Major Appliance Warranty Sécurité DE LA Sécheuse Votre sécurité et celle des autres est très importantePièces fournies Instructions D’INSTALLATIONOutillageetpièces Pièces nécessairesGrille de séchage Exigences demplacementPiédestalfacultatif Nécessaire de superpositionInstallation dans un placard sécheuse seulement Dimensions de la sécheuseEspacement pour linstallation dans un placard Dégagements de séparation à respecterSpécifications électriques Instructions DE Liaison À LA TerreAlimentationengaz Type de gazExigences concernant le raccordement au gaz Exigencesconcernantlévacuation Planification dusystèmed’évacuation Installations d’évacuation facultatives Autres installations où le dégagement est réduitDéterminer litinéraire dacheminement du conduit Tableau des systèmes dévacuation Installation dusystèmed’évacuationInstallationdespieds denivellement Utilisation dans une maison mobileMiseàniveau dela sécheuse RaccordementaugazRaccordementdu conduitd’évacuation Inversion dusens douverturedela porteInversion de la charnière Inversion de la gâche Acheverl’installationRéinstallation de la porte Si la sécheuse ne démarre pas, vérifier ce qui suitUtilisation DE LA Sécheuse MiseenmarchedelasécheuseUtilisation dun programme automatique Verrouillagedes commandes ArrêtouremiseenmarchedelasécheuseConseils pourleséchageetles programmes Témoins lumineux ProgrammesCaractéristiquessupplémentaires Changementdesprogrammes,optionset Modificateurs Option degrilledeséchageNettoyagedu filtreàcharpie NettoyagedelemplacementdelasécheuseEntretien DE LA Sécheuse Nettoyage à chaque chargeNettoyagedel’intérieurdelasécheuse RetraitdelacharpieaccumuléePrécautionsàprendrepourlesvacancesetavantun Déménagement Dépannage FonctionnementdelasécheuseRésultatsdelasécheuse Taches sur la charge ou sur le tambour Temps de programme trop courtCharpie sur la charge Charges froisséesAssistance OU Service AuxÉtats-UnisAu Canada Garantie DES Gros Appareils Ménagers Whirlpool Corporation Garantie Limitée DE Deux ANSW10057260 Whirlpool Corporation All rights reserved